background image

  9

Key Fob Transmitters

Keyfobs can be programmed as “Arm/Disarm” devices using the ON and OFF
buttons (refer to control panel installation instructions).
Press the 

A

 button and for each Key Fob Transmitter, enter:

The Key Fob Transmitter number (01–15).
The area number to which transmitter is assigned (1 or 2); enter 0 to disable
keyfob.
The 6-digit RF ID # printed on the transmitter (enter all numbers and/or
letters, including  leading “0”s, if any).
4  The 1-digit checksum number printed on transmitter.
The Aux-1 Option (see key fob Aux 1 & Aux 2 options).
The Aux-2 Option (see key fob Aux 1 & Aux 2 options).

Press 

J

to save. Then go to step 1

to enter next Key Fob.
When all Key Fobs are entered, press NEXT (

E

) button to proceed.

Note: If the Key Fob is converted for Two Button “Emergency Use”
(by cutting an internal jumper), both top or bottom buttons must  be
depressed to activate an alarm. In this case, the Key Fob may not be
used to arm or disarm the contrl panel.

Key Fob Zone Assignment
Each of the 4 key fob buttons can be assigned to a zone. For example, On button = point 1; Off button = point 2; A1 = point
3; A2 = point 4. Up to 32 key fobs (using 1 button) or 16 key fobs (using 2 buttons) or 8 key fobs (using all 4 buttons) or any
combination up to a maximum of 32 controlled zones can be assigned, providing multiple wireless panic buttons on a
system, each reporting to the Central Station or a pager and/or annunciating on a keypad the key fob zone number with
description/location. To assign a key fob to a zone: program the keyfob as you would a transmitter, entering the keyfob's ID
code, check sum and point number at the appropriate zone. The “Quick Method” is not allowed. The zone may be
hardwired to a sensor as well as assigned to a key fob (either one will activate the zone alarm output). NOTE: If assigning
a key fob to a zone, the “ON/OFF” buttons on the key fob will no longer arm/disarm the system. The key fob is converted
to a “panic only” device.

Dealer Code

Press the 

A

 button directly enter the Dealer Code (default = 456789),

including leading zeros. Use the 

1

 through 

9

 buttons. NOTE: Press

the 

0

 button for a zero. Press 

J

to save.

Re-enter the Dealer Code.

Press 

J

to save. Press NEXT (

E

) button to proceed.

ZONE DESCRIPTIONS: GEM-R3DGTL cannot be used to enter Zone Descriptions. To enter Zone Descriptions you must
use the GEM-RP1CAe2 Keypad or the Napco Quickloader Software.

DATA

ENTRY

AUX 1/AUX 2

OPTIONS

•(blank)

None

9

Keypad Panic

0

Aux K.P. Panic

B

Instant

C

Toggle Aux Relay

D

Access Control

EXIT DEALER PROGRAM MODE: This completes the custom default program. Press the 

C

 button to enter the

Direct Address Program Mode for further programming or press the 

C

 button once again to end all programming and

resume normal keypad operation.

(Direct Entry)

16

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

NOTE: When programming the ID Code number:
   “A” = 

G 0 

; “B” = 

G 1 

;

   “C” = 

G 2 

; “D” = 

G 3 

;

   “E” = 

G 4 

; “F” = 

G 5 

.

  KeyFob #      Area #                 6-digit RF ID #        Checksum #    Aux1 #    Aux2 #

(Direct Entry)

17

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

INTERIOR

BYPASS

SYS TBL

CHIME

FIRE/TBL

 rE

INTERIOR

BYPASS

FIRE/TBL

SYS TBL

CHIME

 Programming the GEM-P816 & GEM-P1632

Summary of Contents for Gemini GEM-P1632

Page 1: ...ll basic programming functions by answering questions which will allow the automatic programming of the control panel F FFor the GEM P816 and GEM P1632 turn to page 5 F FFor the GEM P3200 and GEM P960...

Page 2: ...2...

Page 3: ...crews Uneven walls may cause the keypad case to distort WIRING Connect the keypad wires to the control panel terminals shown in the table at the right Caution Do not run keypad wiring with loop wiring...

Page 4: ...estion may be reviewed before saving After entering the data before pressingJ to save A may be pressed until the 2 digit question number appears flashing in the display again Pressing A will step thro...

Page 5: ...Fire Zones in Area 1 Appears for New Panel Only Press the A button and then directly enter the zone number of any zones which are to be used as Fire Zones both 2 wire 4 wire or wireless Valid entries...

Page 6: ...ng See Keypad Options Central Station Receiver 1 Telephone Number Press the A button and using the number buttons directly enter telephone number of up to 16 digits including prefix if necessary for r...

Page 7: ...ns CHANGING OR CANCELING A CODE To change any code merely program over the existing code as described above and press Jto save Similarly to cancel a code blank out each number of the code press Jto sa...

Page 8: ...Enter the Enroll mode as described in step 2 above 2 Enter Zone 11 3 Open the loops of points 1 and 2 4 Install the transmitter battery The keypad will beep 3 times to indicate that three points have...

Page 9: ...n location To assign a key fob to a zone program the keyfob as you would a transmitter entering the keyfob s ID code check sum and point number at the appropriate zone The Quick Method is not allowed...

Page 10: ...YSTEM Central Station Receiver 1 Telephone Number Press the A button and using the number buttons directly enter telephone number of up to 16 digits including prefix if necessary for receiver 1 NOTE C...

Page 11: ...SYS TBL CHIME INTERIOR BYPASS SYS TBL CHIME FIRE TBL DATA ENTRIES AUTHORITY LEVEL COD E TYPE blank NONE ARM DISARM 1 LEVEL 1 ARM DISARM 2 LEVEL 2 ARM DISARM 3 LEVEL 3 ARM DISARM 4 NONE ARM ONLY 5 LEV...

Page 12: ...Enroll mode as described in step 2 above 2 Enter Zone 11 3 Open the loops of points 1 and 2 4 Install the transmitter battery The keypad will beep 3 times to indicate that three points have been prog...

Page 13: ...up to a maximum of 32 controlled zones can be assigned providing multiple wireless panic buttons on a system each reporting to the Central Station or a pager and or annunciating on a keypad the key fo...

Page 14: ...shown in the adjacent diagram ACCESSING DIRECT ADDRESS PROGRAM MODE 1 Enter the Dealer Security Code default 456789 for a new panel or enter your custom Dealer Program Code if programmed 2 Press A 3...

Page 15: ...15...

Page 16: ...any other person purporting to act on its behalf to modify to change or to assume for it any other warranty or liability concerning its products In no event shall NAPCO be liable for an amount in exce...

Reviews: