GEMC-WL-CO Supervised Wireless Carbon Monoxide Detector Installation Instructions
the unit for at least one year. If battery voltage
drops below normal, the red LED will flash every
45 seconds and a low battery report will be sent to
the control panel. If the voltage is still below nor-
mal after 7 days, the detector sounder will chirp.
The battery should be replaced immediately. Op-
eration of the detector cannot be assured after an
additional 7 days of low-battery indication. A low-
battery report is sent to the receiver with any status
transmission.
NOTE:
Temperature and humidity extremes
may reduce the life of the battery.
Use Only Battery Specified In Marking. Use of A
Different Battery May Have A Detrimental Effect
On Detector Operation.
4. Pick CO-detector location.
The GEMC-WL-CO
must be installed in accordance with the National
Fire Protection Association (NFPA) Standard 720.
Refer to figures in "
Recommended Installation Lo-
cations
" (on page 3) and all text on pages 3 and
4.
Note:
Mounting the GEMC-WL-CO on foil-backed
wallpaper is NOT recommended because the radio
range will be reduced.
5. Install mounting plate.
Use two screws and
hardware appropriate for the mounting surface to
secure the mounting plate to the wall or ceiling.
NOTE:
Do not install on removable surfaces
such as ceiling tiles.
6. Map the GEMC-WL-CO Transmitter.
Referring
to the installation instructions for the control panel
and keypad in use, enter the following:
the zone to which the transmitter will be
mapped
the 6-digit RF identification number / 1-digit
checksum number printed on the transmitter
(include all numbers and/or letters and leading
zeros, if any)
the transmitter point number "1"
7. Attach the GEMC-WL-CO to Mounting Plate.
Match up alignment tabs on the detector and the
Mounting Plate. Turn detector clockwise until it
locks into place (see next image).
8. Test system weekly with unit mounted
and by
pressing the
TEST
button (shown in next image).
Perform the
FUNCTIONAL GAS TEST
annually (if
required by the AHJ) as described in the next sec-
tion.
FUNCTIONAL GAS TEST MODE
Note:
Check with local codes and the AHJ to deter-
mine if a functional gas test is desired for an installa-
tion. If the system is monitored, notify central station
Use screw anchors for wallboard
(This side to
ceiling)
DINING
ROOM
KITCHEN
BEDROOM
BEDROOM
LIVING
ROOM
BEDROOM
Twist the
detector
clockwise to
lock to the
Mounting Plate
Match up
alignment
tabs
CO Entry Ports
Test button