NAPCO F64 CODED Datasheet Download Page 3

F64 Hybrid Control: 

One 8 to 64 zone panel to standardize on

Flexible F64 System Features: 

• 8 Hardwire or wireless zones on board, programmable by area
• Expandable up to 64 zones (through EZM multiplex modules 

and/or 4-zones built-in at each touchpad

• Supports up to 4 areas
• 400 event log; viewable at the touchpad
• F64 supports up to 7 touchpads (F64CODE-K1VPS and -K1V  

as well as Freedom Code-free F64TP models; these may be 
intermixed in the system, too. See WI1640B).

• Supports 2-wire fire (2 zones) & 4-wire fire 
• Supports Gemini Transmitters using 8, 6, 96 point Gemini 

Receivers

• Supports 3 outputs; up to 16 external outputs (RB/RM3008)
• Programmable Telco line-cut and bell-cut
• Reports alarms, restores and troubles by zone.
• One interior zone group.
• Two chimes by zone; programmable duration.
• 2 PGM outputs.
• PCD-WINDOWS (v5.6.1 or higher) - Familiar Napco PC 

programming and PC-preset

• All major communicator formats: SIA, Point ID, 4/2, etc. 
• Fuseless, maintenance-free operation
• Three 20-digit telephone numbers.
• Backup reporting; Double reporting; Split reporting.
• 64 User Codes with opening/closing -reporting by user.
• AC failure reporting with programmable report delay.
• Supervised telephone line with 60 second delay.
• Pager capability
• SIA CP-01 features

F64 System Specifications:

Input Power: 16.5-18.0 VAC via Class 2 Plug-In 20VA, 40VA or 
50VA Transformer
Loop Current: 3mA; 5mA for 2-wire smoke-detector zones
Loop Resistance: 300 Ohm max.; 50 Ohm for 2-wire smoke-
detector zones
Alarm Voltage Output: 1;

 

Programmable Negative Outputs: 2

Auxiliary Power Output: 11.7-12.5 VDC
Remote Power Output: 12 VDC regulated 
Combined Standby Current

 

- See WI1501

UL Listings & Compliances:

Household Burglar Alarm System Units: UL1023
Household Fire Warning System Units: UL985
Security Industry Association (SIA) False Alarm Reduction
Standard CP-01

F64 Coded Kit & Accessories 

Ordering information:

F-64CODEKIT1

 Complete F64 Coded Kit: Coded talking 

touchpad w/built-in siren, PIR, downloadable 8 to 64 zone 
hybrid control, plug-in transformer. 

F-64CODE-K1VPS 

 Additional coded multifunction talking 

touchpad with built-in siren & PIR and smart display, for use with 
KIT1 or 2.

F-64CODEKIT2

, Kit as above, where talking touchpad does not 

include built in Siren and PIR/occupany sensor.

F-64CODE-K1VS 

Additional coded talking touchpad (NO built-

in siren &  NO PIR, for use with KIT2 or 1.

F-64 System options:
PCD-WINDOWS

 (v5.6.1 or higher) Quickloader Downloader 

Software with PC Preset.

F-64TP/TAB 

Freedom Codefree Multifunction Touchpad w/ PIR 

& Siren plus deadbolt lock interface.(May be intermixed with 
F64CODED Touchpads in F64 System (see WI1640B). 

GEM-TEMP64

 Indoor or outdoor temperature sensor displays 

temperature on touchpad display 

GEM-EZM4/8

 4 to 8 zone EZM multiplex expansion module

WI1501

 Control Panel Installation Instructions

WI1502

 Control Panel Programming Instructions

WI1629B

 Installation Addendum

WI1640B

 F64 Touchpad Applications & Configuration 

Instruction

OI318

 Freedom System Users Guide

TRF11

 Transformer, 16.5Vac/40VA, Class 2

TRF14 

Transformer, 16.5Vac/50VA, Class 2

RBAT4

 4Ah 12VA Battery

ALL GEMINI WIRELESS DEVICES 

See back

the power of one panel

One F64 partitionable control panel to standardize on with 8-64-zones 
of power and flexibility for every application. Plus proven Gemini 
wireless support, familiar Napco Quickloader software & now a choice of 
multifunction talking touchpads technologies.

F64 Control Panel:

 64 zones with Gemini crystal-controlled wireless support

Reviews: