![NAPCO F-TPBR Manual Download Page 15](http://html.mh-extra.com/html/napco/f-tpbr/f-tpbr_manual_705727015.webp)
15
SYSTEM TROUBLE ERROR CODES
TBL
Flashes /
Touchpad beeps
READY
Flashes
Trouble Condition
Action
6
NONE
Lost Key Mode
This is a reminder that the system has been put into the lost key mode ([STAY] &
[AWAY] pressed simultaneously). While in this mode, the system can only be disarmed
with your F-IFOB. When you have replaced or re-keyed your deadbolt, press [STAY] &
[AWAY] simultaneously again to exit lost key mode.
7
NONE
Fire Zone Trouble
A problem has been detected with the Fire zone. Call for service.
1 1
Wireless Receiver
TBL or F-TP Touch-
pad TBL
A problem has been detected with the wireless receiver or F-TP Touchpad. Call for ser-
vice.
2 2
Wireless Receiver
Jam
A problem has been detected with a wireless receiver. Call for service.
3 1-8
Wireless Transmitter
Low Battery
The battery in a wireless transmitter is low and should be replaced. This transmitter is on
the zone corresponding to the number of
READY
flashes. The replacement battery for
the GEM-TRANS2 door/window transmitter, GEM-PIR motion detector and GEM-GB
glass break detector is the Duracell DL123A 3 Volt Lithium (2 required for the GEM-PIR
and GEM-GB). The GEM-DT Dual Technology Sensor requires 4 C cell Alkaline batter-
ies.
Warning: Replace batteries only with the same type as specified above. Use of another battery
may present a risk of fire or explosion. Do not recharge or disassemble battery, or dispose of in fire.
4 1-8
Wireless Transmitter
Supervisory Failure
A problem has been detected with a wireless transmitter on the zone corresponding to
the number of
READY
flashes. Call for service.
5 1-4
Wireless Smoke
Detector Low Battery
The battery in a wireless smoke detector is low and should be replaced. The number of
the smoke detector corresponds to the number
READY
flashes. The replacement battery
is the Duracell MN1604 9 Volt Alkaline (2 required).
Warning: Replace batteries only with the same type as specified above. Use of another battery may
present a risk of fire or explosion. Do not recharge, disassemble, or dispose of battery in a fire.
6 1-4
Wireless Smoke
Detector Supervisory
Failure
A problem has been detected with a wireless smoke detector. Call for service.
F-TPBR_OI308.06_USER_anc...
page 15
Friday, October 28, 2005 15:14
Composite