NAPCO EXPRESS XP-600 Programming Instructions Manual Download Page 3

3

Viewing Data in Programming Blocks

To view data within a programming Block, enter the Program Block Number, then press the  

 key, continue pressing the 

 key until all digits within

the Programming Block have been viewed.  Data will be displayed in the binary format shown in the table below:

ZONE LED ON

ZONE LED OFF

0/Blank

1

2

3

4

5

6

7

8

9

*A/0

B

C

D

E

F

ZONE 1

ZONE 2

ZONE 3

ZONE 4

For Technical As-

sistance, Contact

the Napco Toll

Free Helpline 

(800) 645-9440

*

In the following Program-
ming Blocks, data that has
been entered as a ‘0’ will
be displayed as an ‘A’:
Subscriber ID Numbers,
Phone Numbers, Pager
Leading and Trailing digits
and Report Codes.

N

OTE

:

Example: Viewing the Dialing Prefix

A Dialing Prefix of 9E has been programmed at Programming Block Num-

ber 44 (outside access number).  Follow the steps below to view the data.:

Press 

 

to enter Programming Block 44.  The 1st

digit of Programming Block 44 is displayed.

1

Press the 

 key to view the 2nd digit.

2

9

E

44

Dialing Prefix

The Following  Program-
ming Options are not
permitted for UL installa-
tions: [05], [06], [23-2],
[26-3]  and [26-4].

The      symbol by a
programming Block indi-
cates the programming
option is not permitted
for UL installations.

N

OTE

:

UL

For information about
programming blocks re-
fer to XP-600 Installation
Manual WI846C.

N

OTE

:

ZONE 3

ZONE 1

ZONE 2

ZONE 4

Data = 9

ZONE 3

ZONE 1

ZONE 2

ZONE 4

Data = E

Wi847c 
page 3

Tuesday, September 16, 1997 08:35 

Summary of Contents for EXPRESS XP-600

Page 1: ...all original wiring for ter minal 15 PGM and terminal 3 Note Any programming in Dealer Options 1 96 and Dealer Options 2 97 will not be de faulted If Dealer Code Lockout has been programmed the panel...

Page 2: ...adecimal data entry Program Telephone Prefix Number with a 9E 1 Press Beep Beep 2 Press 3 Press 4 Press 2 Direct Entry Programming Block Enter data directly For hexadecimal entries of A F use the key...

Page 3: ...rs Phone Numbers Pager Leading and Trailing digits and Report Codes NOTE Example Viewing the Dialing Prefix A Dialing Prefix of 9E has been programmed at Programming Block Num ber 44 outside access nu...

Page 4: ...Default OFF OFF OFF OFF OFF OFF 04 24 Hour Protection Zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Default OFF OFF OFF OFF OFF OFF 05 40 ms Loop Response Zones Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zo...

Page 5: ...able Output PGM Features 1 Zn 1 LED ON Audio Verification Zn 2 LED ON Access Output Zn 3 LED ON Follow Keypad Sounder Zn 4 LED ON Keyfob Keyswitch Chirp See Note 2 Default OFF OFF OFF OFF 24 Programma...

Page 6: ...OFF OFF 39 Opening Closing Report Telco 1 Zn 1 LED ON User 1 Reporting Zn 2 LED ON User 2 Reporting Zn 3 LED ON User 3 Reporting Zn 4 LED ON User 4 Reporting Zn 5 LED ON User 5 Reporting Zn 6 LED ON U...

Page 7: ...gle Digit Zn 4 LED ON No Handshake Default ON OFF ON OFF 45 Communicator Features 1 Zn 1 LED ON Communicator Enabled Zn 2 LED ON DTMF w Rotary Back up Zn 3 LED ON DTMF only Zn 4 LED ON Backup to Telco...

Page 8: ...Zone 4 Zone 5 Zone 6 Default OFF OFF OFF OFF OFF OFF 55 Zone Restore Report Telco 3 Zone 1 Zone 2 Zone 3 Zone 4 Zone 5 Zone 6 Default OFF OFF OFF ON 56 System Reporting Telco 3 Zn 1 LED ON KP Fire Zn...

Page 9: ...F 63 System Report Codes Keypad Fire 1 1 Keypad AUX 2 3 Keypad Panic 2 1 Test Timer F F AC Fail F 9 Low Battery F 8 Trouble F 1 Fire 1 1 64 System Restore Code E 65 Opening and Closing Code C Closing...

Page 10: ...eyfob 3 84 Keyfob 4 AUX 1 2 Programming 1 Panic 2 AUX 3 Bell ON 4 PGM 5 Instant 6 Access on PGM 7 Full Set System 8 Interior 6PRNH HWHFWRUV RF ID Hexadecimal Data Entry To Enter a hexadecimal digit en...

Page 11: ...ne override Zn 3 LED ON Command 6 Download Zn 4 LED ON Signal Strength Test Mode Default ON OFF OFF OFF 96 Dealer Options 1 Zn 1 LED ON Dealer Code Lockout Zn 2 LED ON User 1 Code Lockout Zn 3 LED ON...

Page 12: ...K EOLR SUPERVISED E COLD WATER GROUND CONNECTION USE ONLY COLD WATER PIPE OR BURIED GROUND ROD USE AT LEAST 16 AWG WIRE TELCO RED GRN GRAY BRN FIRE PWR 2 A P 0 REMOTE BUS ZONE 3 E E ZONE 6 ZONE 5 Z ZO...