GENERAL DESCRIPTION
DESCRIPTION
The C-200AP and C-200APC are dual-technology sensors intended for use
in residential or commercial applications where small animals may be present.
They feature conventional wide-angle coverage patterns that are insensitive
to dogs, cats, etc. weighing up to about 40 pounds. (For larger pets, a
conventional Pet-Alley Lens is provided.) The C-200AP uses a Form-A alarm
relay; the C-200APC uses a Form-C relay.
SPECIFICATIONS (Note: Not all models are equipped with all features.)
General Coverage with standard lens, measured indoors at 20° C (68° F),
typical: 30’x35’
Operating Temperature: –10° to +50° C (14° to 122° F)
Mounting: Wall or corner, 7’ to 8’ max.
Output Relay: Form A (C-200AP): Normally-Closed; Form C
(C-200APC): Normally Closed or Normally Open
Relay Time: Approximately 4 seconds
Contact Ratings: 100mA, 24Vdc with internal 10
Ω
current-limiting resistor
Trouble: Open collector current sinking with 39
Ω
current-limiting resistor,
20mA max.
Status Input*: (Form-A Version only) Panel disarmed, >5V; armed, <1.5V.
Self-Test Interval: 11–16 hours.
Power-Supply Requirements
Note: This unit is intended for operation from a power source that provides
battery backup in the event of a power failure. For UL installations, the backup
battery must be fully recharged within 24 hours and provide 4 hours of standby
operation.
Filtered Dc: 12Vdc
Current Drain at 12Vdc: Idle, 37mA; Alarm, 38mA
Microwave Frequency: 10.525GHz
±
25MHz
Physical
Dimensions: 4.5” x 2.5” x 2.3” (HxWxD) (11.4cm x 6.4cm x 5.8cm)
Shipping Weight: 7oz (200gm)
FEATURES
•
Microprocessor signal processing.
•
Power-up system diagnostic tests virtually all electronics.
•
Microwave and PIR self test.
•
Watchdog microprocessor supervision.
*For UL installations, Status Input is to be connected only to a UL-listed control panel with a UL-tested Status line.