background image

PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MAN U AL FOR FUTURE REF ER ENCE.

Rev. 08/10/18

6-1127

6

TROUBLESHOOTING

IMPACT WRENCHES

TOOL DOES NOT RUN OR RUNS SLOWLY, 

AND/OR AIR FLOWS ONLY SLIGHTLY 

FROM EXHAUST —

 This condition is 

probably caused by insufficient air pressure, 

contaminants blocking the airflow or 

operation of motor parts, or a power regulator 

which has vibrated to a closed position. 

YOU SHOULD: 

Check the air supply for 

sufficient pressure.  Check the air inlet 

strainer for blockage.  Pour a generous 

amount of air tool oil into air inlet.  Operate 

tool in short bursts, in both forward and 

reverse directions. Repeat if necessary.  If 

tool performance does not improve, the tool 

should be serviced by an authorized service 

center.

TOOL WILL NOT RUN, EXHAUST 
AIR FLOWS FREELY. 

This condition is 

probably caused by one or more rotor vanes 
stuck on ac cu mu la ted sludge or varnish; 
motor rusted.

YOU SHOULD:

 Pour a generous amount of 

air tool oil into air inlet.  Operate tool in short 

bursts in both forward and reverse directions.  

Lightly tap the motor housing with a plastic 

mallet.  Detach the air supply.  Try to free the 

motor by turning the drive shaft manually, 

if possible.  If the tool remains jammed, it 

should be serviced by an authorized service 

center.

SOCKETS WILL NOT STAY ON. 

This 

condition is probably caused by a worn 

socket retainer ring or a soft backup o-ring

YOU SHOULD: 

Wear safety goggles.  Detach 

the air supply.  Using external retaining ring 

pliers, remove the old retaining ring.  While 

holding the square drive with an appropriate 

wrench, use a small screwdriver to pry old 

retainer ring out of its groove.  Always pry the 

ring away from your body, because it can be 

propelled outward at high velocity.  Replace 

the backup o-ring and retainer ring with 

correct new parts (see breakdown).  Place 

the retaining ring on a table and press the 

tool anvil into the ring with a rocking motion.  

Snap the ring into the groove by hand. 

PREMATURE ANVIL WEAR. 

This is probably 

cased by using chromed sockets, which are 

not designed for use with impact tools, or 

worn sockets

YOU SHOULD: 

Stop using chrome sockets.  

Chrome sockets have a hard exterior surface 

and a soft core, which leads to a warped 

but very hard drive hole when used with 

impact tools.  Chrome sockets will wear 

wrench anvils quickly and present a danger of 

splitting or breakage which can lead to injury 

or death.

TOOL SLOWLY LOSES POWER BUT RUNS 

AT FULL SPEED WHEN NOT UNDER 

LOAD. 

This condition is probably caused by 

worn clutch parts, inadequate lubrication, or 

worn engaging cam.

YOU SHOULD: FOR OIL LUBED 

WRENCHES:

 Check for presence of clutch 

oil (where oil is specified for the clutch) and 

remove oil fill plug. Tilt to drain all of the oil 

from the clutch case. Refill the case with 

NAPA air tool oil or that recommended by the 

manufacturer in the specified amount.  Also 

check for excess clutch oil.  Clutch cases 

only need to be filled 50%, and overfilling 

can cause drag on high speed clutch 

parts.  A typical 1/2" Drive oil lubed wrench 

only requires 1/2 ounce of clutch oil.  

FOR 

GREASE LUBED WRENCHES:

  Check 

for excess grease by rotating drive shaft by 

hand.  It should rotate freely, and excess 

grease is usually expelled automatically.

TOOL WILL NOT SHUT OFF. 

This condition 

is probably cause by a broken or maligned 

throttle valve O-ring, or a bent or jammed 

throttle valve stem.  

YOU SHOULD: 

Remove the throttle 

assembly and install a new o-ring.  Lubricate 

the assembly with air tool oil and operate 

the trigger briskly.  If operation cannot be 

restored, the tool should be serviced at an 

authorized service center.

AIR RATCHETS

MOTOR RUNS. SPINDLE DOESN'T TURN, 

OR TURNS ERRATICALLY —This condition 

is probably caused by worn teeth on the 

ratchet or pawl, a broken or weak pawl 

pressure spring, or weak drag springs 

which fail to hold the spindle while the 

pawl advances.

YOU SHOULD: 

Have replacement parts 

installed by an authorized service center.

TOOL DOESN’T RUN, RATCHET HEAD 

INDEXES CRISPLY BY HAND— 

This 

condition is probably caused by the 

accumulation of dirt or sludge in motor parts.

YOU SHOULD: 

Pour a generous amount 

of air tool oil into the air inlet.  Operate the 

throttle in short bursts.  With the tool engaged 

on a bolt, alternately tighten and loosen the 

bolt by hand.  If the tool remains jammed, it 

should be serviced at an authorized service 

center

AIR DRILLS

TOOL WILL NOT RUN, RUNS SLOWLY, 

AIR FLOWS SLIGHTLY FROM EXHAUST, 

SPINDLE TURNS FREELY —

 This condition 

is probably caused by a blocked air passage 

or jammed motor parts.

YOU SHOULD: 

Check the air inlet for 

blockages.  Pour a generous amount of 

air tool oil into air inlet.  Operate the trigger 

in short bursts.  Detach the air supply. 

Turn the empty and closed drill chuck by 

hand.  Reconnect air supply.  If the tool’s 

performance does not improve, it should be 

serviced by an authorized service center.

 TOOL WILL NOT RUN. AIR FLOWS FREELY 

FROM EXHAUST.  SPINDLE TURNS 
FREELY. 

This condition is prob a bly caused 

by a broken rotor vane or jammed or broken 
gears.

YOU SHOULD: 

Pour a generous amount of 

air tool oil into air inlet.  Operate the trigger 

in short bursts.  Detach the air supply. 

Turn the empty and closed drill chuck by 

hand.  Reconnect air supply.  If the tool’s 

performance does not improve, it should be 

serviced by an authorized service center.

TOOL SEIZED. SPINDLE WILL NOT  

TURN —

 This condition is probably caused 

by a broken rotor vane or jammed or broken 

gears.

YOU SHOULD: 

Have the tool serviced by an 

authorized service center.

TOOL WILL NOT SHUT OFF — 

The throttle 

valve o-ring has probably come unseated.

YOU SHOULD: 

Replace the o-ring (see 

breakdown) or have tool serviced by an 

authorized service center. 

AIR HAMMERS

TOOL WILL NOT RUN —

 This condition is 

probably caused by a clogged cycling valve 

or throttle valve.

YOU SHOULD: 

Check the air inlet for 

blockages.  Pour a generous amount of 

air tool oil into air inlet.  Operate the trigger 

in short bursts with the chisel in place and 

against a solid surface.  Detach the air 

supply.  Tap the nose or barrel lightly with a 

plastic mallet, reconnect the air supply, and 

repeat above steps.  If the tool is still seized, 

insert a 6" piece of 1/8" diameter rod in the 

nozzle and lightly tap to loosen the piston in 

the rear direction.  Reconnect air supply and 

repeat above steps.

CHISEL STUCK IN NOZZLE— 

This 

condition is probably caused by a deformed 

shank.

YOU SHOULD: 

Have tool serviced by an 

authorized service center.

NOTE: DISASSEMBLY OF THIS TOOL 

BY ANY OTHER THAN AN AUTHORIZED 

SERVICE CENTER WILL VOID THE 

WARRANTY ON THIS TOOL.

SANDERS/GRINDERS

TOOL HAS NO POWER OR RUNS 

SLOWLY. 

This condition is probably caused 

by insufficient air pressure, contaminants 
blocking the air flow, or speed regulator that 
has vibrated to a closed or off position.

YOU SHOULD: 

Check the air supply at 

the compressor and air lines to the tool for 
sufficient air pressure. Check the air inlet 
strainer for blockage and make sure speed 
regulator is in the open or on position. If 
power is not restored the tool should be 
serviced by an authorized service center.

TOOL SEIZED. PAD/SPINDLE WILL NOT 

TURN.

 

This condition is probably caused 

by a broken rotor vane, jammed or broken 
gears, or seized bearing.

YOU SHOULD: 

Have the tool repaired by an 

authorized service center

.

TOOL WILL NOT SHUT OFF/RUNS 

CONTINUOUSLY.

 The throttle valve seat has 

become loose or damaged.

YOU SHOULD: 

 

Replace o-ring or valve seat 

(see breakdown for proper parts) or have tool 
serviced by an authorized service center.

Summary of Contents for 6-1127

Page 1: ...das como agentes causantes del c ncer defectos de nacimiento y otros da os reproductivos Algunos ejemplos de dichas sustancias qu micas son plomo de pintura a base de plomo la silica cristalina proven...

Page 2: ...on this tool users and bystanders High sound levels can cause permanent hearing loss Always use hearing protection as recommended by your employer an OSHA regulations while using this tool users and...

Page 3: ...r unusually long air hoses over 25 feet Minimum hose diameter should be 3 8 I D and fittings should have the same inside dimensions and be tightly secured Always turn off the air supply drain hose of...

Page 4: ...DER 1 17 RS8000BP17 ROTOR BLADE 4 18 RS8000BP18 ROTOR 1 19 RS8000BP19 FRONT END PLATE 1 20 RS10920 BALL BEARING 6000ZZ 1 21 RS8000BP21 INTERNAL GEAR 1 22 RS8000BP22 BALL BEARING 6804ZZ 2 23 RS8000BP23...

Page 5: ...ortant DO NOT RETURN PRODUCT TO PLACE OF PURCHASE WARRANTY POLICY This NAPA Professional Air Tool is warranted against defects in material and workmanship for a period of One 1 Year from the date of o...

Page 6: ...SPINDLE DOESN T TURN OR TURNS ERRATICALLY This condition is probably caused by worn teeth on the ratchet or pawl a broken or weak pawl pressure spring or weak drag springs which fail to hold the spind...

Page 7: ...alimentaci n de aire de 3 8 en di metro Al operar o al realizar el mantenimiento de esta herramienta lleve siempre la protecci n de ojos y cara resistentes al impacto usuarios y espectadores Niveles...

Page 8: ...y los herrajes deben tener la misma dimensi n interior Apague siempre el suministro de aire vac e la manguera de su presi n de aire y desconecte la herramienta del suministro de aire antes de instala...

Page 9: ...acto de mayor tama o No fuerce la llave de trinquete de impacto m s all de su capacidad ya que esto reducir dr sticamente la vida til de la herramienta El bot n de inversi n se utiliza para cambiar el...

Page 10: ...el anillo sujetador con las partes nuevas adecuadas Ver desglose Coloque el anillo sujetador en la mesa y presione al yunque de la herramienta en el anillo con un movimiento mecedor Con la mano cierr...

Page 11: ...tible probablemente se haya desencajada USTED DEBE reemplazar el anillo O ver desglose o llevar la herramienta a un centro autorizado de servicio para que se lleve a cabo el mantenimiento de ella MART...

Page 12: ...NAPA Para una lista completa de centros maestros de reparaci n autorizada consulte el formulario del cliente de reparaci n de garant a o visite www toolwarrantyrepair com DOBLE SU GARANT A Al registra...

Page 13: ...n des yeux r sistant aux chocs quand vous utilisez cet outil ou en faites l entretien utilisateurs et spectateurs Les niveaux sonores lev s peuvent provoquer une perte auditive permanente Portez toujo...

Page 14: ...rieur minimal du boyau doit tre de 3 8 po Les raccords doivent avoir le m me diam tre int rieur et tre serr s solidement Toujours couper l arriv e d air comprim et d brancher l outil avant d enlever o...

Page 15: ...ifique doivent tre v rifi s avec une cl dynamom trique comme tant l tape finale L utilisation du cliquet pneumatique alors que la puissance est en position arr t pour serrer ou desserrer des attaches...

Page 16: ...externe rigide et une structure interne souple L action d un outil chocs muni d une telle douille endommage la prise et rend le serrage difficile Les douilles en chrome endommagent rapidement le mand...

Page 17: ...s l entr e d air Faites fonctionner l outil par saccades avec le burin en place et contre une surface solide D branchez la source d alimentation en air Tapez doucement sur le nez ou sur le corps de l...

Page 18: ...umatiques voyez le formulaire de r clamation en vertu de la garantie ci joint ou rendez vous au www toolwarrantyrepair com DOUBLEZ LA DUR E DE VOTRE GARANTIE Enregistrez votre outil l adresse www prop...