Napa/Evercraft 775-0232 Instruction Manual & Parts Breakdown Download Page 6

Rev. 05/13/02

775-0232

6

PLEASE REVIEW ALL WARNING INSTRUCTIONS PRIOR TO OPERATION. SAVE THIS MANUAL FOR FUTURE REFERENCE.

TROUBLESHOOTING

AIR DRILLS

TOOL WILL NOT RUN, RUNS SLOWLY, AIR FLOWS SLIGHTLY FROM EXHAUST, SPINDLE TURNS FREELY —

This is probably

caused by: air flow blocked by dirt build-up; motor parts jammed with dirt.

YOU SHOULD:

Check air inlet for blockage. Pour a generous amount of air tool oil into air inlet. Operate trigger in

short bursts. Detach air supply; turn empty and closed drill chuck by hand. Reconnect air supply. If tool
performance is not improved, it should be serviced at an authorized service center.

TOOL WILL NOT RUN. AIR FLOWS FREELY FROM EXHAUST. SPINDLE TURNS FREELY — 

This is probably caused by:

Build up of dirt or varnish on rotor vanes.

YOU SHOULD:

Pour a generous amount of air tool oil into air inlet. Operate trigger in short bursts. Detach air

supply; turn empty and closed drill chuck by hand. Reconnect air supply. If tool performance is not improved, it
should be serviced at an authorized service center.

TOOL LOCKED UP, SPINDLE WILL NOT TURN — 

This is probably caused by: a broken motor vane; gears broken or

jammed by foreign object.

YOU SHOULD:

Send the tool to an authorized service center.

TOOL WILL NOT SHUT OFF — 

This is probably caused by: throttle valve O-ring blown off seat.

YOU SHOULD:

See breakdown for part number and replace O-ring or send the tool to an authorized service center.

AIR HAMMERS

TOOL WILL NOT RUN —

This is probably caused by: cycling valve or throttle valve clogged with dirt or sludge.

YOU SHOULD:

Pour a generous amount of air tool oil into air inlet; check for dirt. Operate trigger in short bursts

(chisel in place and against solid surface). If not free, detach air supply. Tap nose or barrel lightly with plastic
mallet, reconnect air supply, and repeat above steps. If still not free, detach air supply, insert a 6" piece of 
1/8" diameter rod in nozzle and lightly tap to loosen piston in rear direction. Reconnect air supply and repeat
above steps.

CHISEL STUCK IN NOZZLE— 

This is probably caused by: the end of the shank is misshapen.

YOU SHOULD:

Send the tool to an authorized service center.

(Continued from page 5)

NOTE

Disassembly of this tool by other than an authorized service center 

WILL VOID

the warranty on this tool.

90 DAY LIMITED WARRANTY: 

NAPA/EVERCRAFT air tools are warranted to be free from defects

in material and workmanship for 90 days from the date of purchase. We will repair or replace at
our option any defective part or unit which proves to be defective in material or workmanship
during this 90 day period.  The  foregoing obligation is NAPA/EVERCRAFT’s sole liability under
this or any implied warranty and under no circumstances shall we be liable for any incidental or
consequential damages. 

Naturally, repairs required by abuse, misuse, damage or repair attempts (by other than a

NAPA/EVERCRAFT authorized service center) are not covered by this warranty.

Return tools or parts to  NAPA/EVERCRAFT Service Center transportation prepaid. Be certain to
include your name and address, evidence of the purchase date and description of the suspected
defect. 

Reviews: