Technisches
Handbuch
SMCI33
Connection and commissioning
Issue: V 2.2
9
Step Action
Note
7
Start the NanoPro software.
The NanoPro main menu
appears.
8
Select the <Communication> tab.
9
In the field "Port", select the COM port to which
the SMCI33 is connected.
The number of the COM
port to which the controller
is connected can be found
in the device manager of
your Windows PC. (System
control/system/hardware).
10
Select the "115200 bps" entry in the "Baudrate"
selection field.
11
Check the current setting using the motor data
sheet.
Under no circumstances
may the current be set to a
value higher than the rated
current of the motor.
12
Select the <Mode> tab.
13
Click on the <Test Record> button to carry out
the pre-set travel profile.
The connected motor
operates with the pre-set
travel profile (default travel
profile after new
installation).
14
You can now enter your required settings.
For instance, you can enter a new travel profile.
See the NanoPro separate
manual.