Technical Manual PD4-E-M (EtherCAT)
10 Description of the object dictionary
Object description
Index
60F4
h
Object name
Following Error Actual Value
Object Code
VARIABLE
Data type
INTEGER32
Savable
no
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
60F8h Max Slippage
Function
Defines the maximum allowed slippage error in user-defined units symmetrically to the set speed in
Profile Velocity mode.
Object description
Index
60F8
h
Object name
Max Slippage
Object Code
VARIABLE
Data type
INTEGER32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000190
h
Firmware version
FIR-v1738-B501312
Change history
Description
If the actual speed deviates so much from the set speed that the value (absolute value) of this object is
exceeded, bit 13 in object 6041
h
is set. The deviation must last longer than the time in object 203F
h
.
If the value of 60F8
h
is set to "7FFFFFFF"
h
, slippage error monitoring is switched off.
A reaction to the slippage error can be set in object 3700
. If a reaction is defined, an error is also
entered in object 1003
.
60FAh Control Effort
Function
This object contains the correction speed in user-defined units that is fed to the speed controller by
the position controller.
Version: 1.0.1 / FIR-v1748
285