10 Description of the object dictionary
6065h Following Error Window
Function
Defines the maximum allowed following error in user-defined units symmetrically to the demand
position.
Object description
Index
6065
h
Object name
Following Error Window
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000100
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1504: "Savable" entry changed from "no" to
"yes, category: application".
Description
If the actual position deviates so much from the demand position that the value of this object is
exceeded, bit 13 in object 6041
h
is set. The deviation must last longer than the time in object 6066
h
.
If the value of the "Following Error Window" is set to "FFFFFFFF"
h
, following error monitoring is
switched off.
A reaction to the following error can be set in object 3700
h
. If a reaction is defined, an error is also
entered in object 1003
.
6066h Following Error Time Out
Function
Time in milliseconds until a larger following error results in an error message.
Object description
Index
6066
h
Object name
Following Error Time Out
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
0064
h
Firmware version
FIR-v1426
Version: 1.0.1 / FIR-v1748