![NANOTEC PD4-C5918M4204-E-01 Manual Download Page 102](http://html1.mh-extra.com/html/nanotec/pd4-c5918m4204-e-01/pd4-c5918m4204-e-01_manual_3241520102.webp)
Manual PD4-C (USB)
12 Object directory description
Version: 1.4.1 / 22.07.2016 / FIR-v1626
102
2034h Upper Voltage Warning Level
Function
This object holds the threshold level for the "Overvoltage" error in millivolts.
Object description
Index
2034
h
Object Name
Upper Voltage Warning Level
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
•
: 00006590
h
•
PD4-C5918M4204-E-01: 0000C92C
h
•
PD4-C6018L4204-E-01: 0000C92C
h
•
PD4-CB59M024035-E-01: 00007530
h
•
PD4-C5918L4204-E-01: 0000C92C
h
•
PD4-C5918M4204-KSAR2: 0000C92C
h
Firmware Version
FIR-v1426
Change History
Description
If the input voltage of the motor controller rises above this threshold value, the motor is switched off
and an error is output. This error is automatically reset when the input voltage is less than (voltage of
the object 2034
h
minus 2 volts).
2035h Lower Voltage Warning Level
Function
This object holds the threshold level for the "Undervoltage" error in millivolts.
Object description
Index
2035
h
Object Name
Lower Voltage Warning Level
Object Code
VARIABLE
Data type
UNSIGNED32
Saveable
yes, category: application
Access
Read/write
PDO Mapping
No
Admissible Values
Specified Value
00002710
h
Firmware Version
FIR-v1426
Change History