![NANOTEC ELECTRONIC N5 Technical Manual Download Page 268](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153268.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Description
The following subindices have a function:
•
01
h
: Not used
•
02
h
: Not used
•
03
h
: Changes the source of object 6044
:
•
Value = "-1": The internally calculated set value is entered in object 6044
h
•
Value = "0": The value is kept at 0
•
Value = "1": The encoder value is entered in object 6044
•
04
h
:
•
Value = "-1": The internally calculated set value is entered in object 6064
h
•
Value = "0": The value is kept at 0
•
Value = "1": The encoder value is entered in object 6064
320Bh Motor Drive Sensor Display Closed Loop
Function
This can be used to change the source for objects 6044
and 6064
in closed loop mode.
Object description
Index
320B
h
Object name
Motor Drive Sensor Display Closed Loop
Object Code
ARRAY
Data type
INTEGER32
Savable
yes, category: application
Firmware version
FIR-v1426
Change history
Value description
Subindex
00
h
Name
Highest Sub-index Supported
Data type
UNSIGNED8
Access
read only
PDO mapping
no
Allowed values
Preset value
04
h
Subindex
01
h
Name
Commutation
Data type
INTEGER32
Access
read / write
PDO mapping
no
Allowed values
Preset value
00000000
h
Version: 2.0.1 / FIR-v1650