![NANOTEC ELECTRONIC N5 Technical Manual Download Page 311](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153311.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
6064h Position Actual Value
Function
Contains the current actual position in user-defined units.
In open loop mode, the source of this object can be set with object 320A
:04
h
to either the internal,
calculated value or to the encoder.
Note
If the encoder resolution in object 2052
=
0
, the numerical values of this object are invalid.
Object description
Index
6064
h
Object name
Position Actual Value
Object Code
VARIABLE
Data type
INTEGER32
Savable
no
Access
read only
PDO mapping
TX-PDO
Allowed values
Preset value
00000000
h
Firmware version
FIR-v1426
Change history
6065h Following Error Window
Function
Defines the maximum allowed following error in user-defined units symmetrically to the demand
position.
Object description
Index
6065
h
Object name
Following Error Window
Object Code
VARIABLE
Data type
UNSIGNED32
Savable
yes, category: application
Access
read / write
PDO mapping
RX-PDO
Allowed values
Preset value
00000100
h
Firmware version
FIR-v1426
Change history
Firmware version FIR-v1504: "Savable" entry changed from "no" to
"yes, category: application".
Version: 2.0.1 / FIR-v1650
311