![NANOTEC ELECTRONIC N5 Technical Manual Download Page 140](http://html.mh-extra.com/html/nanotec-electronic/n5/n5_technical-manual_705153140.webp)
Technical Manual N5 (CANopen)
10 Description of the object dictionary
Savable
no
Access
read only
PDO mapping
no
Allowed values
Preset value
FIR-v1650-B527540
Firmware version
FIR-v1426
Change history
100Ch Guard Time
Function
Object 100C
h
multiplied by object 100Dh Live Time Factor yields the so-called lifetime for the
Lifeguarding / Nodeguarding protocol. The value is specified in milliseconds. See also Nodeguarding.
Note
The Heartbeat protocol has a higher priority than Nodeguarding. If both protocols are activated
simultaneously, the Node Guarding Timer is suppressed, but no EMCY message is sent either.
Object description
Index
100C
h
Object name
Guard Time
Object Code
VARIABLE
Data type
UNSIGNED16
Savable
yes, category: communication
Access
read / write
PDO mapping
no
Allowed values
Preset value
0000
h
Firmware version
FIR-v1426
Change history
100Dh Live Time Factor
Function
This object is a multiplier which, multiplied by object 100C
h
, yields the time window for the
Nodeguarding protocol in milliseconds. See also Nodeguarding.
Note
The Heartbeat protocol has a higher priority than Nodeguarding. If both protocols are activated
simultaneously, the Node Guarding Timer is suppressed, but no EMCY message is sent either.
This object is only available in device variants with CANopen connection.
Version: 2.0.1 / FIR-v1650