NANO Modules - València 2019 ©
FONT
V/Oct Calibration
FONT comes pre-calibrated.
When the
RES
knob is set to its maximum position, the filter starts to behave as an
sine
wave oscillator
. The filter is designed to track well over 5 octaves. In order to track
properly the notes from a controller, these are the steps you should follow:
1.
2.
3.
4.
Set the FREQ knob to 9 o’clock. Set the RES knob to its maximum position.
Disconnect any input signal or FM modulation CV.
Connect the note CV output of a well-calibrated keyboard interface or MIDI-CV
converter to the OCT input.
Listen to the tone at the LP2 output.
Using a screwdriver, adjust the
trimmer resistor
at the back of the circuit board
until the musical intervals played on the keyboard are correctly reproduced.
Summary of Contents for FONT
Page 1: ...FONT Quick guide...