8-l TROUBLESHOOTING POWER UP
SYMPTOM
RELATIVE PROBLEM
SOLUTION
NO POWER
(Check that
is plugged
POWER ON
NO VIDEO
BLOWN FUSE
CHECK FUSE ON POWER SUPPLYAND
REPLACE IF NEEDED
POWER SWITCH
t
VERIFY THAT SWITCH IS ON AND
N O T F U N C T I O N I N G
NOT BROKEN.
OPEN CIRCUIT
VERIFY PLUG IS SECURELY
MATED TO MACHINE.
BAD POWER SUPPLY
WITH A VOLTMETER, CHECK TO
INSURE 110 VOLT
VOLTAGESARE BEING OUTPUT
REPLACE P/S IF NEEDED.
POWER SUPPLY
VOLTAGE
NO RASTER or
RASTER-NO VIDEO
BAD or
O F F - C E N T E R P I C T U R E
VERIFY FAN IS RUNNING AND
APPROPRIATE VOLTAGE IS GOING TO
CRT. SO, THEN CHECK
FUSE ON CRT VIDEO CARD AND
REPLACE NEEDED.
VERIFYALL CONNECTORS ARE
ON AND SECURE.
VERIFY VIDEO CONNECTORTO
CRT VIDEO CARD IS ON CORRECTLY.
VERIFY POWER CONNECTOR TO
CRT IS SECURE, AND CHECK THAT
VOLTAGETOCRT IS
REFER TO SECTION 5-4