NAM system REGGAE Series User Manual Download Page 8

Diagnostic and configuration of serial port RS1
Serial port RS1 serves to connect the communicator to 
a PC with the diagnosis and configuration programme 
NAM-manager  The standard of this connector conforms 
to the standards RS232 (EIA-232-F, ITU V 28)  This serial 
port is not insulated from the remaining parts of the co-
mmunicator  A cable reducer, KAB 08, is used for conne-
cting the circuit board of the REGGAE GT communicator 
to a PC  Please contact the producer, NAM system, a s , for 
more details of this cable reducer 

Communication serial port RS2
Serial port RS2 serves to transfer news from FAS panels 
either through the third-party converters, or in case of 
communicators REGGAE eps GTbzxxx, through direct co-
nnection to the serial interface of the FAS panel  Serial 
port RS2 is brought out to the pin field CON9  The stan-
dard of the serial port on this connector is TTL (3V)  The 
serial port at the TTL (3V) level is not insulated from the 
remaining parts of the communicator  For connections 
with FAS it is necessary to have a module for transfers at 
the TTL (3V) level to the circuit board of the REGGAE GT 
communicator that is at the standard of the serial port of 
the specific FAS interface  The basic type of module for 
uninsulated interfaces TTL (5V) and insulated interfaces 
RS232, RS422 or RS485 are available from the producer, 
NAM system, a s  The description of the modules for the 
insulated serial ports RS232 and RS422/485 can be found 
on page 14  The modules ensure insulation of the seri-
al ports RS232/422/485 from the remaining parts of the 
communicator  Description and technical parameters 
of module TTL (5V) can be found in the actual manual  
REGGAE reduction TTL 3V/5V 

Relay outputs
On the circuit board of the REGGAE GT communicator 
there are two relay outputs RE1 a RE2 implemented by 
two independent relay contact switches 

The terminal plate markings are standard  The mutual 
outlet of the switch contact is marked „C“ (Common)  The 
contact outlet that is clamped close when the status is 
idle-circuit is marked „NC“ (Normally-Closed)  The con-
tact outlet that is in release when the status is idle-circuit 
is marked „NO“ (Normally-Open) 

The carrying capacity of each relay output is a maximum 
of  1 A / 30 VDC (respectively 0 3 A / 60 VDC) or 0 5 A / 125 
VAC 

U

S

E

R

 

M

A

N

U

A

L

REGGAE GT/GTbz 

Communicator for GSM (GPRS/SMS) transmission

www.namsystem.com

8

Summary of Contents for REGGAE Series

Page 1: ...U S E R M A N U A L REGGAE GT GTbz Communicator for GSM GPRS SMS transmission Document 1 60...

Page 2: ...rd 12 Safety fuses 12 Operating time of REGGAE GT GTbz GTbzxxx communicators using the back up accumulator 12 Modules RS422 485 a RS23 13 Connecting modules RS422 485 13 Connecting modules RS232 13 IN...

Page 3: ...locally via serial port or remotely via GPRS channel Communication between REGGAE GT or REGGAE GTbz GTbzxxx and REGGAE eps GTbzxxx and ARC takes place in both directions with confirmation of receipt...

Page 4: ...AE GTbz232 and REGGAE GTbz485 is not possible near medical instruments and other equi pment sensitive to electromagnetic field The manufacturer shall not be liable for any damages re sulting from inte...

Page 5: ...nputs Outputs 8 insulated voltage loop 2 changeover relay contact max 1 A 30 VDC 0 3 A 60 VDC 0 5 A 125 VAC Communication channels serial port RS1 standard RS232 uninsulated R D T D RTS CTS serial por...

Page 6: ...Tbzxxx Power voltage Supply current Medium wattage Power frequency Output voltage AUX Output current AUX Output fuse AUX Type of backup battery Capacity of backup battery Battery charge current Operat...

Page 7: ...ce does not contain this type of fuse at its output it is necessary to add this to the power carrier of the communicator as close as possible to the power source output Voltage of insulated inputs The...

Page 8: ...circuit board of the REGGAE GT communicator that is at the standard of the serial port of the specific FAS interface The basic type of module for uninsulated interfaces TTL 5V and insulated interfaces...

Page 9: ...ED LD1 to LD4 on the circuit board of the REGGAE GT communicator serve to indicate the present state of the REGGAE communicator The meaning of the LED indication lights are as follows LD1 blue state o...

Page 10: ...he AS panel from the FW 6 xx communicators This function is optio nal in the communicator configuration The terminal plates marked T1 and T2 are used for connecting telephone lines from the AS panel I...

Page 11: ...power source circuit board ensures automatic dis connection of the accumulator in cases where its open circuit voltage falls below 8 9 V during operation of the communicator by the accumulator this m...

Page 12: ...urce Safety fuse F1 6A protects the circuit source against the reserval of poles on the accumulator It also protects the accumulator in the case of serious violations of the out put circuit source Ope...

Page 13: ...osed connector J1 is connected to end resistor 120 between inputs A B Closed connectors J3 and J4 conne ct inputs A B with outputs Y Z for interface RS485 Clo sed pins 1 and 2 of connector J5 set a po...

Page 14: ...s check the strength of fixation in order to prevent later injury or property damage caused by the communicator box fa lling down Connecting the GSM GPRS antenna GSM GPRS antenna must be placed outsid...

Page 15: ...es marked RING and TIP on the communicator REGGAE GT circuit board Connecting the telephone line In case of disturbance on the telephone line PSTN vol tage drop on the line the line is automatically d...

Page 16: ...ust then be close to the device and must be easily accessible Overcurrent protection must be part of the installation of the soc ket If necessary the flexible supply line with plug can be replaced by...

Page 17: ...G Receiver Main channel for communication with NSG Encrypted connection via internet Backup channel for communication with NSG GSM GPRS Output Sur Guard Serial assisted by MOXA convertor or via TCP IP...