User Manual
HRU-WALL
•
If any abnormalities in operation are detected, disconnect the device from the mains supply and contact a
qualified technician immediately. Use original spare parts only for repairs.
•
The electrical system to which the device is connected must comply with regulations.
•
Before connecting the product to the power supply or the power outlet, ensure that: the data plate (voltage
and frequency) correspond to those of the electrical mains and the electrical power supply/socket is adequate
for maximum device power. If not, contact a qualified technician.
•
The device should not be used as an activator for water heaters, stoves, etc., nor should it discharge into hot
air/fume vent ducts deriving from any type of combustion unit. It must expel air outside via its own special
duct.
•
Operating temperature: -20°C up to +50°C.
•
The device is designed to extract clean air only, i.e. without grease, soot, chemical or corrosive agents, or
flammable or explosive mixtures.
•
Do not leave the device exposed to atmospheric agents (rain, sun, snow, etc.).
•
Do not immerse the device or its parts in water or other liquids.
•
Turn off the main switch whenever a malfunction is detected or when cleaning.
•
For installation an omnipolar switch should be incorporated in the fixed wiring, in accordance with the
wiring regulations, to provide a full disconnection under overvoltage category III conditions (contact opening
distance equal to or greater than 3mm).
•
If the supply cord is damaged, it must be replaced by the manufacturer, its service agent or similarly qualified
persons in order to avoid a hazard.
•
Do not obstruct the fan or exhaust grille to ensure optimum air passage.
•
Ensure adequate air return/discharge into/from the room in compliance with existing regulations in order to
ensure proper device operation.
•
If the environment in which the product is installed also houses a fuel-operating device (water heater, methane
stove etc., that is not a “sealed chamber” type), it is essential to ensure adequate air intake, to ensure good
combustion and proper equipment operation.
2.2 Directives / Norms
•
2014/35/EU Low Voltage Directive (LVD) and 2014/30/EU Electromagnetic Compatibility (EMC), in
conformity with the following standards:
•
Electrical Safety: EN60335-1(2012)+A11+A13; EN 60335-2-80(2003) +A1+A2.
•
Electromagnetic Compatibility: EN 55014-1(2017); EN 55014-2 (2015); EN 61000-3-2(2014); EN 61000-
3-3(2013).
3. Technical data
3.1 Features
•
Tube material: high quality, impact and UV-resistant ABS colour RAL 9010.
•
Design front cover removable for cleaning without the use of tools.
•
Easy maintenance installation plate, for easy access to the heat exchanger from inside the room.
•
Anti-dust filter, easily removable for washing by the user without tools.
•
Regenerative honeycombs ceramic heat exchanger.
•
External grille in high quality, external hood in aluminium, painted in white RAL 9010, acoustically lined.
•
High efficiency aerodynamic fan with “winglet” blades to optimise quietness and efficiency.
•
Single phase EC reversible brushless motor with integral thermal protection.
•
Motor mounted on high quality ball bearings.
•
The unit is double insulated: no earth connection is required.
•
Trickle speed selectable.
• Boost mode.
• Free-cooling (Bypass single direction) mode.