background image

7. Recycling

EEC Standards, together with the responsibility we should assume with future generations in mind, 

oblige  us  to  recycle  all  the  materials  we  can.  Therefore,  please  deposit  all  left-over  material  and 

packaging  in  their  corresponding  recycling  containers  and  hand  in  the  replaced  machines  to  the 

nearest handler of this type of waste product.

If you have any queries about the products, please contact our after-sales service oryour local dealer.

8. Energy classes

 

E

2018

1254/2014

33

 

dB

ENERGIA · ЕНЕРГИЯ · ΕΝΕΡΓΕΙΑ · ENERGIJA · ENERGY · ENERGIE · ENERGI

 A

++

 A

+

 A

+++

 A

++

 A

+

 A

-80%

 A

-60%

 A

-40%

 A

-20%

530 m

3

/h

DV-PP-L-150

Model

Noise level

 [dB]

Air flow

[m

3

/h]

Energy class

DV-PP-L-100

31

155

E

DV-PP-L-125

31

220

E

DV-PP-L-150

33

530

E

 

6.5.2 Run on timer instruction

15min

20min

25min

30min

7.5min

5min

10min

5min

P

30min

A1

N

A2

E

A1

N

A2

1.  Run on time comes preset for 10min.

2.  Can adjust delay-time between 5 min and 30min.

3.  Arrow P Point to the delay-time.

15

ALNOR

®

 

ventilation systems

is a legally protected trademark and technical patent. All rights reserved.

w

w

w

.al

nor

.com.
pl

User’s manual

DV-PP-L

Summary of Contents for DV-PP-L Series

Page 1: ...Wentylator kana owy DV PP L INSTRUKCJA OBS UGI USER S MANUAL Sierpie 2019 r Duct fan DV PP L Model DV PP L 100 DV PP L 125 DV PP L 150...

Page 2: ...w i u ytkownika 3 1 2 Bezpiecze stwo w trakcie monta u 3 2 Uruchomienie 4 3 Konserwacja 4 4 Transport i przechowywanie 4 5 Monta i demonta 5 6 Pod czenie elektryczne 6 6 1 Diagram pod czenia 6 6 2 Dia...

Page 3: ...uj ce standardy Standard zgodny z Dyrektyw niskonapi ciow 2006 95 WE Standardy kompatybilno ci elektromagnetycznej zgodne z dyrektyw 2004 108 WE 4 Wentylatory lub urz dzenia je obejmuj ce zosta y zapr...

Page 4: ...cji przy urz dzeniu prosz si upewni e jest ono od czone od zasilania nawet je eli zosta o wcze niej wy czone Prosz dopilnowa aby nikt nie mia mo liwo ci ponownego pod czenia urz dzenia do zasilania w...

Page 5: ...5 Monta i demonta 1 Zdejmij klamr zaciskow 1 Zdejmij zacisk rubowy 2 Przymocuj baz 3 Zamontuj korpus silnika Dla modeli DV PP L 100 DV PP L 125 Wyj tkowy projekt wspornika pozwala na to aby centralny...

Page 6: ...nym Ma e wymiary gabarytowe wentylator w DV PP L u atwiaj monta w trudno dost pnych miejscach gdzie przestrze jest ograniczona 6 Po czenie elektryczne br zowy br zowy br zowy br zowy niebieski niebies...

Page 7: ...ia y LB LA N N MOC N KOMUN LB MA A PR DKO LA DU A PR DKO C PRZE CZNIK L 15min 20min 25min 30min 7 5min 5min 10min 5min P 30min A1 N A2 E A1 N A2 15min 20min 25min 30min 7 5min 5min 10min 5min P 30min...

Page 8: ...szego punktu zbieraj cego tego typu odpady W razie pyta na temat produkt w prosz skontaktowa si z naszym serwisem posprzeda owym lub z miejscowym sprzedawc 8 Klasy energetyczne E 2018 1254 2014 33 dB...

Page 9: ...13 6 1 Wiring diagram 13 6 2 Wiring diagram with a speed controller 13 6 3 Wiring diagram with a switch control 14 6 4 Wiring diagram for the model with delay timer switch 14 6 4 1 Speed setting 14 6...

Page 10: ...tic Compatibility 2004 108 CEE 4 Ventilators or apparatus that include them have been designed to move the air in the area stipulated on their characteristics plate 5 This apparatus must not be used i...

Page 11: ...bility of anyone else connecting it while it is being manipulated 2 The apparatus must be regularly inspected These inspections should be carried out bearing in mind the machine s working conditions i...

Page 12: ...odels The unique design of the support bracket allows the central cartridge holding the motor and impeller as sembly to be fitted or removed without dismantling the ductwork For DV PP L 150 model ALNO...

Page 13: ...s 6 Wiring brown brown brown brown speed controller blue blue black black white white N LB LA N LA LB N N POWER POWER N COMMUN LB LOW SPEED LA HIGH SPEED N COMMUN LA HIGH SPEED L L 6 1 Wiring diagram...

Page 14: ...15min 20min 25min 30min 7 5min 5min 10min 5min P 30min A1 N A2 E A1 N A2 PLUG SV brown brown black black white blue L LT N COM MH ML POWER MOTOR HIGH HIGH LOW LOW RUN ON TIMER SPEED SETTING 5min 30mi...

Page 15: ...our after sales service oryour local dealer 8 Energy classes E 2018 1254 2014 33 dB ENERGIA ENERGIJA ENERGY ENERGIE ENERGI A A 530 m3 h DV PP L 150 Model Noise level dB Air flow m3 h Energy class DV P...

Page 16: ...ut prior notification PRODUCENT zastrzega sobie prawo do wprowadzenia wszelkich ulepsze technologicznych lub modyfikacji bez wcze niejszego powiadomienia ALNOR ventilation systems is a legally protect...

Reviews: