Nakayama SP1040 Quick Start Manual Download Page 8

5

Attention!

INSTALLATION AND COMMISSIONING

8.The float switch must be clamped at the card line so that it 

can normally float, control, turn on and off. This should be 

checked, and the floating ball switch should be carefully picked 

up and put down again. When you do this, pay attention to the 

switching status of the switch.

9.Ensure the distance between the top of the floating switch 

and switch line card buckle is not too small. If the distance is 

too small, it cannot guarantee normal work.

10.When you set up the float switch, make sure that the switch 

does not touch the base before the pump is opened. Warning: 

There is a risk of dry running. 

Risk for equipment damage! 

Do not lift the pump by cable or pressure hose,be-

cause these cables or pressure hoses are not 

designed for tensile strength from pump weight.

The float switch must be able to move freely and the 

submersible pump cannot be used in a dry environ-

ment.
Attention:

For rope handling: Do not operate the pump without 

the pressure hose to prevent the pump from twist-

ing around its longitudinal axis. In continuous use 

of a pump with a rope, the condition of the rope 

must be checked periodically, as it may break with 

increasing use time.

Summary of Contents for SP1040

Page 1: ...www NakayamaTools com SP1040...

Page 2: ...www NakayamaTools com RCCB 30m A 16...

Page 3: ...www NakayamaTools com 350 60 60 cm 1 2 3 4 5 6 1 1...

Page 4: ...www NakayamaTools com 2 2 1 2 1 2 1 2 1 2 1 2 1 2 350 C SP1040 230 V 50 Hz 1000 W IPX8 40 m 6500 l h 7 m 1 mm...

Page 5: ...and don t press the power cord 4 The power supply voltage must be the same as the voltage given on the model board 5 To avoid hazards all installation and replacement of compo nents can only be carrie...

Page 6: ...the main power supply 14 Please contact technical staff 15 Connectors for power plugs and extension cables must be made sure that they are watertight and must not be placed in the water Furthermore co...

Page 7: ...g the length of the power line 2 Please check the following items before the pump startsrun ning 3 A float switch must be installed so that it is easy to switchbe tween the ON and OFF switching points...

Page 8: ...ou set up the float switch make sure that the switch does not touch the base before the pump is opened Warning There is a risk of dry running Risk for equipment damage Do not lift the pump by cable or...

Page 9: ...e pump and dip it into the liquid to be conveyed at a certain angle so that the lower side of the device has no bubble formation to prevent the bubbles from being sucked in Put the equipment down slow...

Page 10: ...t 2 Clean the pump and replace worn parts Reasons Errorshooting ERROR SHOOTING In most cases you will be able to troubleshoot problems easily by yourself Before you contact us please refer to the foll...

Page 11: ...le occasions Process equipment Products marked with adjacent symbols shall not be treated as domestic rubbish You must deal with these old electrical and electronic equipment separately Please contact...

Page 12: ...ubmersion depth Max Grain size Max supply height 1 mm SP1040 230 V 50 Hz 1000 W IPX8 40 m 6500 l h 7 m Attention Risk for equipment damage The particle size mentioned cannot be used for simple gravel...