EN
WWW.NAKAYAMATOOLS.COM
5
5) Cover the machine with plastic dustcoat and store in a dry and clean place.
Cleaning
1) Clean chemical container
Callback remaining chemical liquid and wash it. Fill one litre water into chemical tank and then swing it lightly.
2) Clean the inside liquid pump
After cleaning chemical tank, fill clean water again and start liquid pump to mist to clean the whole pipeline.
3) Clean the filter net
(1) Clean the filter net in the mouth of chemical tank.
(2) Clean the filter net of suction inside the chemical tank.
There is a filter net of suction at the bottom of chemical tank to avoid the dust coming by the filter net of the mouth of chemical tank to be sucked into liquid
pump. The filter of suction is jammed to spray abnormally and infect the liquid pump greatly. So please take out the filter of suction to clean carefully after
operating. Fix it cautiously after cleaning.
The remaining chemical liquids and the water washed the machine don’t flow into rivers, lakes, ponds or cloacae in order to avoid pollution. Please deal with
it innoxiously.
Maintenance on the battery
In the course of operation, it should be master the frequency and time of charge according to actual condition and referring to usual spray frequency and
time. It’s best to charge when the battery discharge the 60%--70%, the average charging time is about 8 hours. Long time to charge may cause the battery to
loose water, hot and reduce the life.
When we stock the battery, it must not be without any power. Without power means after we use the battery, we couldn’t recharge it on time. If we stock
the battery without power, it will easily get vitriolization, lead sulfate crystal ,which jammed the road of the electric ions, and make the power not enough,
also the capacity of the battery will be lower. If the battery without power too long time, the battery will be harmed more seriously. Therefore, if we don’t
use the battery for time being, we should charge it once each month, which then we can keep the battery in good situation.
● It is normal that the charger is little hot while charging.
● Overcharge or overdischarge will cut the life of battery remarkably.
● Don’t joint the battery directly, or it will harm the safe character of the battery.
● Don’t disassemble and assemble the battery. The battery has the protection equipment, if you alter it, it will make the battery heat and split.
● Don’t connect the anode and cathode of the battery with metallic material. Don’t transport battery with metallic material, or it will make the battery leak,
heat and split.
● Don’t charge in wet room or with wet hands, or you will get an electric shock.
● Please use the special charger for this machine in order to avoid fire. In addition, it is prohibited to charge other electrical machines with the special charg-
er of this machine or as the power.
● Don’t let this machine in the sun, high temperature condition and the things radiating heat, or it will accelerate the old of the battery, make the battery
leak liquids, radiate heat, split and fire.
● Don’t adopt generator as the electrical source of charging, or it will destroy the charger.
● The light of the charger will light if you recharge immediately after ending charge, it is normal. But this will result in overcharge and you should avoid the
operation.
● If you find the charger abnormal, pull out the plug immediately in order to avoid electric shock, radiating heat and making fire.
● Don’t throw the battery into the fire or heat it up, or it will make the battery split and electrolyte splashed.
Replace the fuse
In order to protect the wire and electrical machine, this machine is equipped with fuse. If blowout due to something, please unplug the right and left fixed
equipment, take out the assembly of battery, lax the packing belt, remove the battery, open the cap of fuse to replace the damaged fuse with new one. In
addition, please find out the cause of blowout and remedy it. After this, you could operate it again.
Some causes of blowout:
The charger doesn’t coincide with the battery or has trouble.
The pesticide sticks to the liquid pump.
The wire is short circuit due to the damage.