Thank you for purchasing this product. Please read these instructions, and keep them for future reference.

This tool is an electric pump. It is used for pumping water and other similar water applications. 

After opening the package, please ensure that the products are complete (if any).

If the products are damaged or there is something missing, please do not use it and bring it back to your dealer.

If you give this tool to another person, please give him this instruction manual.

1. All electrical sockets must be earthed.

2. No power cord should be used for transporting or fixing the equipment.

3. Don’t pull the power cord on the sharp edge and don’t press the power cord.

4. The power supply voltage must be the same as the voltage given on the model board.

5. To avoid hazards, all installation and replacement of components can only be carried out by authorized customer service personnel.

6. Electrical connections can only be performed by electrical professionals, and please comply with state regulations for this.

7. The pump must be connected with a current type leakage current breaker which carry a rated leakage current of no more than 30 MA.

8. Check the connection of the plug before running. If the wire is damaged, it must be replaced by the manufacturer, the agent or the relevant technical 

personnel to avoid any danger.

9. Children are not allowed to wash or maintain equipment without supervision.

10. Liquid contamination may be caused by leakage of lubricating oil.

11. The water pump can be connected with a shock proof plug installed in accordance with the regulations.

12. Do not use pumps when there is someone in the water.

13. When cleaning and maintaining, please disconnect the water pump from the main power supply.

14. Please contact technical staff.

15. Connectors for power plugs and extension cables must be made sure that they are watertight and must not be placed in the water. Furthermore, connec

-

tors cannot be placed on the ground. It is recommended to ensure that the outlet is at least 60 mm from the ground.

Long enough and strong ropes should be attached to the handle before the first use. When the pump is immersed into the liquid, the rope along with a 

handle can be used to balance the pump.

Installation

The equipment requires an area of at least 60x60cm.

Depth of equipment immersed in technical parameters.

When installing the equipment, make sure that the suction opening will not be blocked by foreign objects to keep the equipment stable.

Set toggle switch(floater)

1. The floater can be adjusted according to the requirements of the job. Adjust the length of the cable according to the requirements of the operation.

2. Please check the following items before the pump starts running:

3. A float switch must be installed so that it is easy to switch between the ON and OFF switching points. This should be checked, and the floating switch 

should be carefully picked up and put down again. When you do this, pay attention to the switching status of the switch.

4. Ensure the distance between the top of the floating switch and switch line card buckle is not too small. If the distance is too small, it cannot guarantee 

normal work.

5. When you set up the float switch, make sure that the switch does not touch the base before the pump is opened. Warning: There is a risk of dry running.

6. Set the switch to automatically control the height of the water level by adjusting the position of the float switch cable at the card line.

7. The float switch must be firmly fixed to the top of the pump so that it can turn the pump on and off properly. Check the floater and make sure it is working 

properly by lifting and releasing it carefully.

Warning: 

There is a risk of dry running.

Connecting pressure pipe

- Screw the pressure pipe onto the pressure connector. All joint connections must be sealed with a threaded sealing stripe.

- When using the hose, screw the right hose adapter into the pressure connector.

- Secure the hose firmly to the hose adapter and secure it with a hose clamp.

If it is used occasionally, please use a suitable pipe. A rigid pipe with a check valve is recommended for use in a fixed position. This can be done at the close of 

the machine to prevent liquid back flow.

Use a strong rope to connect the handle of the pump and dip it into the liquid to be conveyed at a certain angle, so that the lower side of the device has no 

bubble formation to prevent the bubbles from being sucked in. Put the equipment down slowly, and once the pump is submerged, it can be adjusted again. 

The pump is arranged at the bottom of a liquid container. Fasten the end of the rope after lowering so that the pump can also be handled when hanging on 

the rope. The pump can work after the device is connected to the main power source.  

Safety Instructions

Installation and commissioning

None follow of the safety tips will have the life risk brought by the current! 

Risk of equipment damage! 

Attention:

Do not repair the power cord if there is any external damage to the power cord or plug

.

Do not lift the pump by cable or pressure hose, because these cables or pressure hoses are not designed for tensile strength from pump weight. 

The float switch must be able to move freely and the submersible pump cannot be used in a dry environment.

For rope handling: Do not operate the pump without the pressure hose to prevent the pump from twisting around its longitudinal axis. In continu

-

ous use of a pump with a rope, the condition of the rope must be checked periodically, as it may break with increasing use time.

EN

EN

WWW.NIKOLAOUTOOLS.GR

Summary of Contents for NP1040

Page 1: ...ART NO NP1040 019893 v2 2 WWW NIKOLAOUTOOLS GR FR RO el SL EN IT BG...

Page 2: ...e following items before the pump starts running 3 A float switch must be installed so that it is easy to switch between the ON and OFF switching points This should be checked and the floating switch...

Page 3: ...he electric motor overheats The liquid is too hot Blockage by a foreign object Eliminate the reason of overheating The safety RCCB is activated Turn off the safety The electric motor has a malfunction...

Page 4: ...s must only be carried out by technicians of the authorized service department of the manufacturer Always use the product with the supplied equipment Operation of the product with non provided equipme...

Page 5: ...s es pour quilibrer la pompe Installation L quipement n cessite d une surface d au moins 60x60cm Profondeur de l quipement immerg dans les param tres techniques Lors de l installation de l quipement a...

Page 6: ...r s petit Utilisez un tuyau de plus grand diam tre Le tuyau est obstru Nettoyage Le canal d admission est bloqu Nettoyage Le tube de pression est pli Ajuster le tuyau et remplacer la canalisation Fuit...

Page 7: ...me des ordures m nag res Vous devez traiter ces vieux quipements lec triques et lectroniques s par ment Veuillez contacter les autorit s locales pour savoir s ils peuvent tre trait s correctement En t...

Page 8: ...nciare la pompa Installazione L apparecchiatura richiede un area di almeno 60x60cm La profondit di immersione dell apparecchiatura indicata nei parametri tecnici Quando si installa l apparecchiatura a...

Page 9: ...rdita del tubo Impermeabilizzare il tubo La pompa molto rumorosa Problema con l aspirazione Assicurarsi che la quantit di liquido sia sufficiente Tenere la pompa in posizione obliqua durante l immersi...

Page 10: ...he ed elettroniche devono essere trattate separatamente Contattare le autorit locali per verificare se possono essere gestite correttamente Le vecchie apparecchiature possono essere riciclate trattate...

Page 11: ...11 1 2 3 4 5 6 7 30 8 Service 9 10 11 12 13 14 15 60 mm 60x60 cm 1 2 3 4 5 6 7 8 T EL WWW NIKOLAOUTOOLS GR...

Page 12: ...12 35 C The pump cannot start O RCCB EL WWW NIKOLAOUTOOLS GR...

Page 13: ...13 Service NP1040 900 Watt 230 V 50 Hz IPX8 8 5 m 14 000 l h 7 m 35 mm EL WWW NIKOLAOUTOOLS GR...

Page 14: ...BG 14 WWW NIKOLAOUTOOLS GR 1 2 3 4 5 6 7 30 8 9 10 11 12 13 14 15 60 mm 60x60 cm 1 2 3 4 5 6 7...

Page 15: ...BG 15 WWW NIKOLAOUTOOLS GR 35 C RCCB...

Page 16: ...BG 16 WWW NIKOLAOUTOOLS GR NP1040 900 230 V 50 Hz IPX8 8 5 14 000 7 35...

Page 17: ...e stikalo 1 Plavajo o napravo lahko prilagodite glede na zahteve delovnega mesta Dol ino kabla prilagodite glede na zahteve dela 2 Preden rpalka za ne delovati preverite naslednje elemente 3 Plavajo...

Page 18: ...Premajhen pretok Ve ja vi ina Nastavite pravilno najve jo sesalno vi ino Premer cevi je zelo majhen Uporabite cev ve jega premera Cev je zama ena isto Sesalni vhod je blokiran isto Tla na cev je upog...

Page 19: ...posebnimi nastavitvami opravljajo le tehniki poobla enega servisnega oddelka proizvajalca Izdelek vedno uporabljajte s prilo eno opremo Uporaba izdelka z opremo ki ni prilo ena lahko povzro i motnje v...

Page 20: ...torul flotant 1 Plutitorul poate fi reglat n func ie de cerin ele de lucru Regla i lungimea cablului n func ie de cerin ele opera iunii 2 V rug m s verifica i urm toarele elemente nainte ca pompa s nc...

Page 21: ...pa Debit prea mic n l ime crescut Seta i la n l imea maxim de aspirare corect Diametrul evii este foarte mic Folosi i o eav cu diametru mai mare Conducta este obstruc ionat Curat Intrarea de aspira ie...

Page 22: ...fectuate numai de c tre tehnicieni ai departamentului de service autorizat al produc torului Utiliza i ntotdeauna produsul cu echipamentul furnizat Func ionarea produsului cu echipamente care nu sunt...

Page 23: ...e regula ons apply to this warranty Les ou ls lectriques sont fabriqu s selon des normes strictes tablies par notre soci t et se sont align es sur les normes de qualit europ ennes respec ves Les ou ls...

Page 24: ...dokument o kupovini elektri nog alata maloprodajni ra un ili faktura Ni pod kojim okolnos ma kompanija ne e pokri relevantne tro kove rezervnih delova i potrebno odgovaraju e radno vreme ako se ne pre...

Page 25: ...igueur et fabriqu avec soin l aide de mat riaux usuels et de qualit La p riode de garan e est de 24 mois pour une u lisa on non profes sionnelle et 12 mois pour une u lisa on professionnelle et d bute...

Page 26: ...ali naro i nadomestne dele ali dodatno opremo se obrnite na spodnji prodajni center Pridr ujemo si pravico do sprememb brez predhodnega obves la MLT GARANYIJA Dan l apparat huwa prodo ta kwalit Kienet...

Page 27: ...care sunt supuse uzurii naturale Dac dori i s solicita i o garan ie s semnala i defec iuni sau s comanda i piese de schimb sau accesorii v rug m s contacta i centrul de asisten tehnic Pot modi cate f...

Page 28: ...nuk do t lloj p r pjes t rezerv q mund t merren Ne nuk mund t ofrojm nj garanci p r d m min dhe defektet e pajisjeve ose pjes ve t tyre t shkaktuara nga p rdorimi i forc s s tep rt traj mi dhe sh rbi...

Page 29: ......

Reviews: