Nailor D35SE Installation And Operation Manual Download Page 2

Nailor Industries Inc. reserves the right to change any information concerning product or specification without notice or obligation.

6/20 

IOM-EHVAV (Supercedes 4/02)

Page 2 of 4

 

  

 

  

FAN POWERED

 

(UNITE TERMINALE @  

   

 

 

 

 

  

TERMINAL UNIT

 

VENTILATEUR 

INTEGRÉ) 

 

 

   

 

 

   

 

 

 

   

DATE  

(DATE)

  

27-Nov-2001 

SERIAL NO. 

(NO. DE SÉRIE)

 :  150111-2 

 

 

MODEL (MODÈLE) 

 

D35SE 

TAG NO. 

(NO. DÈTIQUETTE)

 :  FPB-1-35 

 

 

UNIT SIZE-INLET SIZE 

4-10 

VOLTAGE 

(VOLTAGE)

 

: 480   

 

(DIAMETRE D’ENTRÉE) 

                 

PHASE 

(PHASE)

 

: 3 

 

 

CONTROL VOLTAGE 

24 

STAGES 

(ÉTAPES) 

 

: 2 

(

VOLTAGE DE CONTRÔLE) 

              

HZ. 

(HZ)

 

:  50/60  

 

CONTROL SEQUENCE      :  

NB 

MOTOR  HP 

(MOTEUR HP)

  : 1/3   

 

     

(SEQUENCE DE CONTRÔLE)

   

MOTOR VOLTAGE 

:  277 

 

 

VOLT AMP

 (VOLT-AMPÈRE) 

 :  50 

 (VOLTAGE DU MOTEUR)

 

 

 

   

 

HOT WATER COIL ROWS  : 

N/A 

MOTOR AMP  

:  2.0 

 

 

(NOMBRE DE RANGÉES SERPENTIN EAUCAUDE)        

(AMPERAGE DU MOTEUR) 

 

 

   

 

  

KW/HP 

 

 

AMPS 

 

 

AMPACITY  

 

MAX. OVERCURRENT PROTECTION 

MOTOR FUSE SIZE

 

 

 

 

 

(AMPÈRES) 

 

 

(AMPACITÉE) 

 

(RESISTANCE DES FUSIBLE MAX.) 

 (MOTEUR FUSIBLE) 

 

TOTAL 

EACH CIR. 

EACH STG. 

TOTAL 

EACH CIR.  EACH  STG. 

TOTAL 

EACH CIR.  EACH STG. 

TOTAL 

EACH CIR. 

 

(TOTALE) (CHAQUE (CHAQUE (TOTALE) (CHAQUE (CHAQUE (TOTALE) (CHAQUE (CHAQUE 

(TOTALE) 

(CHAQUE

 

 

CIRCUIT)  ÉTAPE) 

 

CIRCUIT)  ÉTAPE) 

 

CIRCUIT) ÉTAPE) 

 

CIRCUIT) 

 

HEATER (CHAUFFAGE) 

10.0 10.0  5.0  12.0 12.0  6.0  15.0 15.0  7.5 

20 

20 

N/A 

MOTOR (MOTEUR) 

1/3      2.0  2.5    

 

30

 

TOTAL (TOTALE) 

       14.0  17.5    

23 

 

 

 

 

 

   

 

 

 

    

 

  

 

 

EACH ELEMENT RATED @ 

3.3 

KW    @ 

277 

VAC. 

AWG. MIN  WIRE SIZE (MIN DIAMETRE DE FIL) : 

14

 

(CHAQUE ELEMENT CLASSIFIER A)

   

 

 

 

MIN. HEATING CFM (MIN. PCM) : 

700

 

 

   

 

 

 

    

 

 

USE WIRE SUITABLE FOR  AT  LEAST  75 

o

UTILISER UN FIL METALIQUE QUI CONVIENT AU MOIN 75 

o

C

 

    

 

L1 IS COLOR CODED BLACK , L2 IS BLUE, L3 IS RED 

L1 EST COLORÉ NOIRE, L2 EST BLUE , L3 EST ROUGE, 

 

    

 

CONTROL WIRES CODED AS MARKED 

LES FILS DE CONTRÔLE SON INDENTIFIÉE COMME MARQUE,

 

USE COPPER CONDUCTORS ONLY. 

UTILISÉ DES CONDUCTEURS DE CUIVRE SEULEMENT. 

 

   

 
 

USE CLASS  K, RK1, A2D OR A6D FUSE OR HACR BREAKERS. 

UTILISÉ DES FUSIBLES CLASS K, RK1, A2D, OU A6D OU HACR DISJONCTEURS.

 

   

 

  

 

 

 

PRIMARY CFM  (MAX/MIN)  : 

1000/1000 

PRIMARY L/S (MAX/MIN)  : 

472/472   

 

FAN CFM  

 : 

 

FAN L/S 

 

 

 

NAMEPLATE LABEL

Electric coil data are incorporated in the nameplate label, 

which is affixed to the control enclosure cover. The label 

shows all necessary information required by UL with respect 

to electrical power and circuit protection requirements.

HEATER CONTROL ENCLOSURE

Figure 4 shows the interior of a typical heater control 

enclosure.  All components within this space work together 

to provide safe operation of the heater.  Although it is not 

required to meet NEC requirements, Nailor recommends a 

door interlocking disconnect switch

.  This safety switch 

must be disconnected before the enclosure can be opened. 

In the absence of a disconnect switch, a 

terminal block

 

is provided for single point power connection.  A 

ground 

lug 

ensures the proper grounding of the unit housing and 

enclosure.  

Line fuses and fan motor fuses

 provide 

overcurrent protection, and come as an option.  An 

airflow 

switch

 de-energizes the heater when it detects no airflow 

across the elements.

In fan powered VAV terminal units, 

auto-reset limit 

switches

 in line with each element provide high temperature 

protection. A single 

auto-reset limit switch 

provides 

protection for single duct terminal unit heaters. These 

switches automatically cut the heater off when overheating 

occurs, and turn the heater back on when the elements have 

cooled down. 

Manual-reset limit switches

 in line with each 

element provide secondary over temperature protection in 

single duct terminal units.  
A control 

transformer

 is provided whenever a 24V circuit 

is required.  

PE switches

 (when pneumatic controls are 

used), like 

magnetic contactors

, are used to energize 

stages of electric heat.  Small heaters may often use a load 

carrying PE switch as the only control component.  When 

control systems require frequent cycling or silent operation, 

mercury contactors 

are available as an option.  An 

SCR 

control

 will provide fine space temperature control and 

highest reliability.  For fan-powered terminal units, a 

fan 

relay

 is provided when required or requested.

Figure 3. Sample Nameplate Label. Fan Powered Terminal Unit

Summary of Contents for D35SE

Page 1: ... point power connection INSTALLATION All single duct terminal units with electric coils are designed to be mounted in a horizontal plane with respect to the UP arrow marked on the product label Fan powered units can be flipped over in the field and will not have UP arrow Before applying power make sure electric coils are not damaged All field wiring must comply with NEC and local building codes Us...

Page 2: ...EL Electric coil data are incorporated in the nameplate label which is affixed to the control enclosure cover The label shows all necessary information required by UL with respect to electrical power and circuit protection requirements HEATER CONTROL ENCLOSURE Figure 4 shows the interior of a typical heater control enclosure All components within this space work together to provide safe operation ...

Page 3: ...re on the side of the terminal electric heater section 1 Turn off power supply before servicing 2 Locate the element rack header plate 3 Before removing wires from the element rack header plate mark where the wires are connected so they can be reconnected correctly on the new element rack 4 Remove the wires and screws holding the heater plate in the coil housing 5 Insert the new element rack into ...

Page 4: ...600V 30Amp EC CONM30A3P SCR SSR SCR Elect Heat controller 600V 1ph 45A EC SCR SSR Elect Heat controller 600V 1ph 45A EC SSR Transformers Transformer 120V 24V 50VA EC TRANS120A Transformer 208 240V 24V 50VA EC TRANS208A Transformer 277V 24V 50VA EC TRANS277A Transformer 480V 24V 50VA EC TRANS480A Isolation Transformer 24V 24V 40VA EC TRANS2424 Transformer 120V 208 240 480 to 24V 75VA EC TRANSB Tran...

Reviews: