background image

9

9

Fig. 8

1.. Clean the Grille and Ca

Use water and a mild detergent. Do not use bleach 
or abrasives.
Do not splash water directly onto the main unit. Doing
so may cause an electrical shock, cause the insulation
to deteriorate, or cause the unit to rust.
The air intake and outlet grilles get soiled easily, so use
a vacuum attachment or brush to clean.

2.. Clean the buck

Every few weeks, clean the bucket to prevent growth of mold,
mildew and bacteria. Partially fill the bucket with clean water 
and add a little mild detergent. Swish it around in the bucket,
empty and rinse.

NOTE:

 Do not use a dishwasher to clean the bucket.

After clean, the bucket must be in place and securely 
seated for the dehumidifier to operate.

3.. Clean the air filt

The air filter behind the front grille should be
checked and cleaned at least every 30 days
or more often if necessary.

NOTE: DO NOT RINSE OR PUT THE FILTER
IN AN AUTOMATIC DISHWASHER.

To remove:

Grip the tab on the filter and pull it upward, then 
pull it out  as shown in Fig.8.
Clean the filter with warm, soapy water. Rinse and
let the filter dry before replacing it. Do not clean the
filter in a dishwasher.

To attach:

Insert the air filter into the unit from underside to 
upside. See Fig.10.

CAUTION:

DO NOT operate the dehumidifier without a filter
because dirt and lint will clog it and reduce
performance.

4.. When not using the unit for long time perio

After turning off the unit, wait one day before emptying 
the bucket.
Clean the main unit, water bucket and air filter.
Cover the unit with a plastic bag.
Store the unit upright in a dry, well-ventilated place.

CARE AND MAINTENANCE

Care and cleaning of the dehumidifier

Turn the dehumidifier off and remove the plug from the wall outlet 

before cleaning.

Fig. 9

Fig. 10

Summary of Contents for Diloc D.18TU

Page 1: ...USER MANUAL D 22TU USER MANUAL PLEASE NOTE Read carefully this manual before install and or use the product Keep this manual for future consultation EN...

Page 2: ...e 1430 volte pi elevato rispetto ad 1kg di anidride carbonica CO per un periodo 2 di 100anni In nessun caso l utente deve cercare di intervenire sul circuito refrigerante o di aprire il prodotto In ca...

Page 3: ...lla targa del prodotto e che l impianto sia conforme alle norme vigenti 16 Pericolo di lesioni non usare il prodotto per scopi diversi da quelli per cui stato costruito Non fare uso errato dell appare...

Page 4: ...k of experience and knowledge if they have been given supervision or instruction concerning use of the appliance in a safe way and understand the hazards involved Children shall not play the appliance...

Page 5: ...rd Do not place the unit near a heat source Before cleaning turn off the power and unplug the unit Do not use the machine near flammable gas or combustibles such as gasoline benzene thinner etc CAUTIO...

Page 6: ...unit If water enters the unit turn the unit off and disconnect the power contact a qualified service technician Do not place flower vases or other water container on top of the unit The manufactures n...

Page 7: ...to initiate the Auto start and Auto stop feature in conjuction with the and key pads 1 1 1 1 2 2 3 3 4 4 5 5 6 6 7 7 Unit operation on indicator light 8 8 High fan indicator light Timer on off indica...

Page 8: ...error Unplug the unit and plug it back in If error repeats call for service ES Temperature sensor error Unplug the unit and plug it back in If error repeats call for service Auto Restart If the unit b...

Page 9: ...automatically controlled according to the actual room humidity The unit will quit dryer mode after a maximum 10 hours operation NOTE The Dryer mode must be operated in a close room do not open the do...

Page 10: ...spill water A dehumidifier operating in a basement will have little or no effect in drying an adjacent enclosed storage area such as a closet unless there is adequate circulation of air in and out of...

Page 11: ...e bucket is restored in its correct position NOTES When you remove the bucket do not touch any parts inside of the unit Doing so may damage the product Be sure to push the bucket gently all the way in...

Page 12: ...should be checked and cleaned at least every 30 days or more often if necessary NOTE DO NOT RINSE OR PUT THE FILTER IN AN AUTOMATIC DISHWASHER To remove Grip the tab on the filter and pull it upward t...

Page 13: ...idity control may not be set low enough Check that all doors windows and other openings are securely closed Room temperature is too low below 5 C 41 O O F There is a kerosene heater or something givin...

Page 14: ...ge and or defects resulting from modifications or adaptations made to the product without prior written authorization issued by Naicon in order to conform it to technical or technical standards nation...

Page 15: ...Note...

Page 16: ...Naicon SRL Via il Caravaggio 25 Trecella I 20060 Pozzuolo Martesana Milan Italy Tel 39 02 95 003 1 Fax 39 02 95 003 313 www naicon com e mail naicon naicon com made in China...