1.
UNSWITCHED CONVENIENCE OUTLET
These 25A outlets always provide unfiltered power, even when the CPD-1006L is switched off. They
are not controlled by the delay switches nor connected to the
15A Circuit Breaker (2)
.
2.
15A CIRCUIT BREAKER
The CPD-1006L’s current rating is 15A (max). If the current draw of the connected equipment
exceeds 15A, the breaker will trip and cut off the power. Disconnect some equipment or otherwise
lower the current draw to enable use of this unit. You can then turn on the power again by pressing
the breaker button.
3.
POWER SWITCH
When it’s switched to “ON” the unit will provide power to the outlets sequentially from Zone 1
through Zone 6 in turn. The sequence delay time is factory set at 2 seconds, but can be factory
adjusted also to 1 or 3 seconds (contact the Nady Service Department to change internal delay
adjustment). The sequence for powering off will be reversed when it’s switched to “OFF”. When
“ON” the
Zone Indicators Display (4)
and
Voltmeter Display (5)
will light up.
4.
ZONE 1 - 6 DISPLAY
The LED indicators will light or turn off indicating when components connected to the ZONE
1/2/3/4/5/6 outlets are powered on and off.
5.
VOLTMETER DISPLAY
When the unit is powered “ON”, this 3-digit display will light and indicate numerically the supply
voltage to the entire audio system connected to the Zone outputs.
6.
LED RACK LAMP
To illuminate your unit and other rack gear mounted below it, pull out the retractable LED light and
rotate to angle desired (+/- 30° from vertical). The lighting is adjustable with the
Dimmer Switch (7)
.
7.
DIMMER SWITCH
To adjust the illumination level of the
LED Rack Lamp (6)
select either “HIGH” (for brightest light),
“OFF”, or “LOW” (for dimmest light).
CONTROLS AND CONNECTIONS
FRONT PANEL
4
(3)
(2)
(1)
(4)
(6)
(7)
(5)