background image

INSTALLATION

4

To ensure years of enjoyment from your NADY AUDIO TMP-3 please read and understand this manual thoroughly before
using the unit.

INSPECTION

Your TMP-3 was carefully packed at the factory in packaging designed to protect the units in shipment. Before installing and using your
unit, carefully examine the packaging and all contents for any signs of physical damage that may have occurred in transit.

(Note: Nady Systems is not responsible for shipping damage.  If the unit is damaged, do not return to us, but notify your dealer and the
shipping company immediately to make a claim. Such claims must be made by the consignee in a timely manner.)

CONTENTS:

• TMP-3 (verify that the unit’s serial number is same as shown on shipping carton)
• AC Power cord
• Instruction manual
• Warranty Card

RACK MOUNTING

The TMP-3 fits into one standard 19" rack unit of space (1 3/4"). Parts of the unit can become very warm during use. This is normal
during operation. Care should be taken to ensure that there is enough space around the unit for cooling (at least 12” or 30cm). Do not
place the TMP-3 on high temperature devices such as power amplifiers, etc., or the unit may overheat in operation. Also, do not place
the unit on speakers as this may cause them to move and/or fall due to speaker vibrations.

Although the unit’s chassis is shielded against radio frequency (RF) and electromagnetic interference (EMI), extremely high fields of RF
and EMI should be avoided.

POWER CONNECTION

The TMP-3 has an internal power supply and is designed to operate from an external AC source.  Power requirements for electrical
equipment differ from area to area. Be sure to confirm that the voltage selected by the voltage selector switch on the back panel is
proper for your area (120 VAC/60 Hz or 230 VAC/50Hz) per the information below:

Europe (except UK): 230V, 50Hz

UK and Australia: 240V, 50Hz

USA and Canada: 120V, 60 Hz

For other areas, please check with local authorities.

When ready to operate, plug the AC cord into the power source.  Make sure that the unit is turned off before connecting to the AC
power source to avoid possible loud transients which can damage your speakers or your ears, especially when monitoring with
headphones.

Summary of Contents for TMP-3

Page 1: ...TMP 3 MIC PREAMP TUBE CHANNEL MIC PREAMP WITH EQUALIZER AND COMPRESSOR O W N E R S M A N U A L ...

Page 2: ...lly to get the most out of your new unit Thanks for selecting NADY AUDIO as your choice in mic preamps FEATURES 2 WARNING 3 INSTALLATION 4 CONTROLS AND CONNECTORS 5 Front Panel 5 Back Panel 6 CONNECTION 6 MIC PREAMP SETTINGS 6 COMPRESSOR SETTINGS 6 USING THE SIDE CHAIN 7 EQUALIZER SETTINGS 7 USING THE PROCESSES TOGETHER 7 SPECIFICATIONS 7 LEGAL INFORMATION 7 Smooth warm tube sound with superior cl...

Page 3: ...in the ears you should consult an audiologist 5 The product should be positioned so that proper ventilation is maintained 6 The product should be located away from heat sources such as radiators heat vents or other devices including amplifiers that produce heat 7 The product should be connected to a power supply only of the type described in the operating instructions or as marked on the product R...

Page 4: ...ough space around the unit for cooling at least 12 or 30cm Do not place the TMP 3 on high temperature devices such as power amplifiers etc or the unit may overheat in operation Also do not place the unit on speakers as this may cause them to move and or fall due to speaker vibrations Although the unit s chassis is shielded against radio frequency RF and electromagnetic interference EMI extremely h...

Page 5: ... adds from 0dB to 10dB of gain 6 CLIP LED When lit this LED indicates clipping or possible distortion in the mic preamp circuits Reduce the GAIN CONTROL 5 so that this LED only lights occasionally 1 9 8 7 6 5 4 3 2 10 11 12 13 14 15 7 LOW LEVEL EQ CONTROL Adjusts level of low frequencies from 20Hz to 150Hz 8 MID LEVEL EQ CONTROL Adjusts level of mid frequencies as selected by the MID SWEEP 9 contr...

Page 6: ... used at one time Do not connect to both at the same time or the signal will be severely distorted CONTROLS AND CONNECTORS 16 17 18 19 20 CONNECTION Make sure the TMP 3 power cord is properly connected to a grounded AC outlet Note examples illustrating proper connection of microphones and instruments to the TMP 3 Do not use both inputs at the same time After the TMP 3 has been properly connected t...

Page 7: ...dB Equalizer Settings LOW SHELF 150Hz HIGH SHELF 10KH MID FREQUENCIES 300Hz 5KHz Q 1 Compressor Settings THRESHOLD 30dB to 20dB RATIO 2 1 to 8 1 Indicators PHANTOM POWER CLIP POWER ANALOG VU METER Input Output Jacks XLR balanced 1 4 unbalanced 1 4 TRS unbal Side Chain Dimensions 19 x 1 75 x 6 483 x 44 x 162mm Weight 3 5 lbs 1 75 Kg and the RATIO 13 control low fully counterclockwise This is a very...

Page 8: ...il at service nady com International For service please contact the NADY AUDIO distributor in your country through the dealer from whom you purchased this product DO NOT ATTEMPT TO SERVICE THIS UNIT YOURSELF AS IT CAN BE DANGEROUS AND WILL ALSO VOID THE WARRANTY NADY SYSTEMS INC 6701 SHELLMOUND STREET EMERYVILLE CA 94608 Tel 510 652 2411 Fax 510 652 5075 www nady com ...