background image

CONTROLS AND CONNECTIONS

FRONT PANEL

The Nady PEQ-5B has five parametric filters organized in five
different frequency bands. A 12-segment LED display shows
the input or output level, and there is both a master low-cut
and high-cut filter. 

1. POWER SWITCH

To turn the unit ON or OFF, press the upper or lower portion
of this button.

2. MASTER INPUT/OUTPUT LEVEL METER DISPLAY

This 12-segment LED meter is used to monitor the signal lev-
els, so as to avoid overload distortion. The display shows the
input or output level as selected by the AUDIO IN/OUT switch
(INPUT is selected with the switch pressed in). The top red LED
lights at a level of about +18 dB, which is about 3 dB below
clipping.  

(Note: Extreme boost settings in combination with a high input
level can cause overload clipping. If this happens, reduce the
input level as necessary with the INPUT control.)

3. MASTER AUDIO IN/OUT SWITCH WITH LED INDICATOR

This is used to enable/disable the entire equalizer section in
the audio path, allowing A/B comparisons between the
processed and unprocessed signals. The switch uses a relay-
controlled hard-bypass function, so that if it is not pressed in
or if the unit is switched off, the inputs are directly connected
to the outputs. The switch also selects the input or output sig-
nal for display on the INPUT/OUTPUT LEVEL meter. The LED
lights when the switch is IN.

6

6

3

4

5

4. MASTER INPUT CONTROL

Use this CONTROL TO DETERMINE THE INPUT LEVEL TO THE
UNIT. It can be set from -15 to + 15dB.

5. MASTER LOW CUT CONTROL

Use this control to adjust the lower cutoff frequency of the
PEQ-5B. The high pass filter can be tuned from 10 to 400 Hz.
In the 10 Hz position the signal passes unchanged.

6. MASTER HIGH CUT CONTROL

Use this control to adjust the upper cutoff frequency of the
unit. The low-pass filter can be tuned from 2.5 to 30 KHz. In
the 30 KHz position the signal passes unchanged.

7. BAND LEVEL CONTROLS

Use this control to determine the amount of level boost/cut for
each band. The setting ranges from -15 to + 15 dB.

8. BAND IN/OUT SWITCHES WITH LED INDICATORS

Use these switches to enable/disable specific bands in the
audio path. The LED lights when the switch is IN.

9. BANDWIDTH CONTROLS

Use these controls to determine the "Q" or slope of the filter in
each band. Settings range from 0.03 (Q=43) to 2 octaves
(Q=0.67).

10. BAND FREQUENCY CONTROLS

Use these controls to select the filter's center frequency in each
band. This can be any frequency within that band's frequency
range.

INPUT/OUTPUT LEVEL(dB)

-30

-24

-18

-12

-6

-3

0

+3

+6

+9

+12

+18

PEQ-5B

5 Band

Parametric 

Equalizer

 

20kHZ-400kHz

BAND

1

60HZ-1kHz

BAND

2

150HZ-2.5kHz

BAND

3

500HZ-8kHz

BAND

4

1kHZ-20kHz

BAND

5

POWER

AUDIO

HIGH CUT

LOW CUT

INPUT

IN

dB

-10

 

 

 

-10

0

+5

-15

+15

75

110

10

400

22

25

50

Hz

7

10

15

2.5

30

KHz

OUT

-5

+10

200

3.5

22

LEVEL

BANDWIDTH

AUDIO

FREQUENCY

IN

-5

dB

-10

 

 

 

-10

0

+5

-15

+15

0.8

1.2

0.03

2

22

0.1

0.4

OCTAVE

80

110

150

20

400

Hz

OUT

-5

+10

40

1.6

250

-10

LEVEL

BANDWIDTH

AUDIO

FREQUENCY

IN

-5

dB

-10

 

 

 

0

+5

-15

+15

0.8

1.2

0.03

2

0.1

0.4

OCTAVE

160

250

350

60

1k

Hz

OUT

-5

+10

80

1.6

550

-10

IN

-5

dB

-10

 

 

 

0

+5

-15

+15

0.8

1.2

0.03

2

22

0.1

0.4

OCTAVE

400

600

900

150

2.5k

Hz

OUT

-5

+10

200

1.6

22

-10

LEVEL

BANDWIDTH

AUDIO

FREQUENCY

IN

-5

dB

-10

 

 

 

0

+5

-15

+15

0.8

110

0.03

2

22

0.1

0.4

OCTAVE

1.5

1.8

2.7

2.5

30

kHz

OUT

-5

+10

0.7

1.6

4.6

-10

LEVEL

BANDWIDTH

AUDIO

FREQUENCY

IN

dB

-10

 

 

 

0

+5

-15

+15

0.8

1.2

0.03

2

22

0.1

0.4

OCTAVE

7

4

6.5

2.5

20

KHz

OUT

-5

+10

1.5

1.6

10

LEVEL

BANDWIDTH

AUDIO

FREQUENCY

1.4k

1

10

8

7

9

2

Summary of Contents for PEQ-5B

Page 1: ...5 15 0 8 1 2 0 03 2 22 0 1 0 4 OCTAVE 80 110 150 20 400 Hz OUT 5 10 40 1 6 250 10 LEVEL BANDWIDTH AUDIO FREQUENCY IN 5 dB 10 0 5 15 15 0 8 1 2 0 03 2 0 1 0 4 OCTAVE 160 250 350 60 1k Hz OUT 5 10 80 1...

Page 2: ...rametric equalizers Date of Purchase__________________________ Dealer s Name____________________________ City_____________________________________ State___________ Zip______________________ Model ____...

Page 3: ...should 1 be undamaged 2 never share an outlet or extension cord with other devices so that the outlet s or extension cord s power rating is exceeded and 3 never be left plugged into the outlet when no...

Page 4: ...s etc Each band independently switchable and adjustable in bandwidth 03 to 2 octaves wide allowing a range of adjustment from tight notching to extreme boost attenuation by band overlapping Constant Q...

Page 5: ...uipment connected to the equalizer 4 Power Connection The PEQ 5B is designed for operation from 120 240 volts 50 60 Hz AC supplies Power requirements for electrical equipment differ from area to area...

Page 6: ...400 Hz In the 10 Hz position the signal passes unchanged 6 MASTER HIGH CUT CONTROL Use this control to adjust the upper cutoff frequency of the unit The low pass filter can be tuned from 2 5 to 30 KHz...

Page 7: ...ower rat ing 120 VAC 250mA 250V 230 VAC 125mA 250V If it continuously blows stop replacing the fuse and refer servicing to qualified personnel CAUTION After checking the AC supply voltage be sure that...

Page 8: ...a tion available it is easy to modify the entire spectrum of the signal being processed at once The added filters allow both high and low broadband corrections while the parametric fil ters process hu...

Page 9: ...by ear although that requires some trial and error and a bit of patience or more effectively by the use of an audio spectrum analyzer Resonance frequencies can then be quickly identified enabling qui...

Page 10: ...se at various points in the room are all about the same If they are not then you may need to make corrections to your setup check system and speaker phasing etc to minimize the variations you are meas...

Page 11: ...15 dB to 15 dB variable FREQUENCY RANGE Band 1 20 400 Hz Band 2 60 Hz 1 Khz Band 3 150 Hz to 2 5 KHz Band 4 500 Hz to 8 KHz Band 5 1 KHz to 20 KHz FUNCTION SWITCHES Master Audio In Out Band In Out for...

Page 12: ...O product require service please contact the Nady Service Department via telephone at 510 652 2411 or E mail at service nadywireless com International For service please contact the NADY AUDIO distrib...

Reviews: