background image

Shower Base Installation Manual

Base de douche Manuel d'installation

BS-RT3648-W3

2-1/2˝(60mm)

3-3/8˝(85mm)

1-1/8˝(30mm)

2-3/4˝(70mm)

36˝(914mm)

1-1/8˝(30mm)

48˝(1219mm)

3-35/64˝(90mm)

24˝(615mm)

4-9/16˝(116mm)

18˝(457mm)

)

m

m5

2

1

)

m

m0

6(˝

8/

3-

2

This indentation is designed to ensure 

the water goes back to the shower base, 

towards the drain.

Cette fente est conçue pour permettre à l'eau de 

retourner vers l'intérieur de la base de douche, 

vers le drain.

Rev

.Aug.23,2019

Summary of Contents for BS-RT3648-W3

Page 1: ...0mm 36 914mm 1 1 8 30mm 48 1219mm 3 35 64 90mm 24 615mm 4 9 16 116mm 18 457mm m m 5 2 1 m m 0 6 8 3 2 This indentation is designed to ensure the water goes back to the shower base towards the drain Cette fente est conçue pour permettre à l eau de retourner vers l intérieur de la base de douche vers le drain Rev Aug 23 2019 ...

Page 2: ...e l installation Avant l installation de la base toute la charpente et les travaux de plomberie doivent être complétés conformément à la présente feuille d instruction Pour les travaux de rénovation les surfaces murales existantes doivent être enlevées pour installer le cadrage exigé Assurez vous que les murs extérieurs sont isolés correctement et que le pare vapeur a été installé conformément aux...

Page 3: ...A B C D 90 A 02 C 90 D Enlever la péllicule de plastique protectrice Remove protective plastic film A 01 BASE INSTALLATION INSTALLATION BASE SUITE CONTINUED 3 A 03 ...

Page 4: ...SUITE CONTINUED FORET 1 8 1 8 DRILL BIT A 05 A 04 SUITE CONTINUED 4 ...

Page 5: ... céramique Ceramic tiles Gypse Gypsium Silicone Montant mural Wall stud Vis R ef A Screw Ref A VUE SECTIONNELLE SIDE SECTION VIEW A 07 Pellicule Film Base Base Mor er Mortar A 06 Vis Screw SUITE CONTINUED SUITE CONTINUED FLOOR PLANCHER Mortar IMPORTANT 5 ...

Page 6: ... installer votre porte de douche afin de permettre au mortier et à la finition de sécher complètement WARNING Wait 24h before proceeding with the installa tion of the shower door This will ensure that the finish and mortar is dry 20 30mm SUITE CONTINUED SUITE CONTINUED 6 ...

Page 7: ...f God or breakage resulting from a shock or mishandling regardless of the part played by the buyer or the installer It also excludes the damages caused by an improper installation NADOLI doesn t cover damages caused by a water leak even if they result directly or indirectly from a product defect except where the applicable legislation does not allow any exclusion or limitation following indirect o...

Page 8: ...e ne couvre pas les dommages causés par les actes de Dieu ou les bris résultant d un choc ou d une mauvaise manutention Elle exclut aussi les dommages qui résultent d une mauvaise installation D emblée NADOLI ne couvre jamais les dommages aux biens causés par une fuite d eau que ceux ci soient directement ou indirectement liés à un défaut du produit sauf là où la législation applicable ne permet a...

Reviews: