S3200P&S2200 Series Installation Guide
Installation Guide
NADDOD Pte. Ltd.
23
Figure 2-3
Step 5
Horizontally fix suspension loops onto the guide slots of the chassis to complete the installation,
as shown in Figure 2-4.
Figure 2-4
2.2.2 Installation and Disassembling of Power Module
Installation Procedure
The power module of S3200P series switches support hot plug, and the installation procedure
is as below:
Step 1
Operators must wear anti-electrostatic wrist strap. Make sure that the anti-electrostatic wrist
strap contacts the skin properly and is grounded properly.
Step 2
Figure out the correct directions of power supply (otherwise it is unable to install the power
supply onto the base in a safe way).
Step 3
Select a power supply socket to install power module. Operators must face the power supply
socket of switch squarely.
Step 4
Figure out the correct directions of power supply (for inserting power module, the side with
text of power module is forward direction). Hold the handle of power module with one hand,