NADDOD S3200P/S2200 Series Ethernet
Switches Installation Instruction Manual
Page 1: ...NADDOD S3200P S2200 Series Ethernet Switches Installation Instruction Manual...
Page 2: ...com Customer complaint hotline 400 0698 860 Address of headquarters of the Company 302 Building F1 Optics Valley Software Park Guanshan 1st Road East Lake High tech Zone Wuhan P R China Postcode 43000...
Page 3: ...ws Product name Hardware version S3200P 24T4X S3200P 48T4X S2200 24T4X S2200 48T4X Stipulations Symbol Stipulations The following symbols may appear in the document of which the meanings are as below...
Page 4: ...ave your time General Format Stipulations Format Description Song The main body is in Song Gothic Level 1 title Level 2 title Level 3 title and Block are in Gothic Regular Warnings and hints are in Re...
Page 5: ...ion 11 1 4 1 Service Port 11 1 4 2 Management Port 14 1 5 S3200P S2200 Series Indicator Description 15 1 5 1 System Indicator 15 1 5 2 Power Indicator 15 1 5 3 Port Mode Indicator 16 1 5 4 Ethernet Ma...
Page 6: ...rt Parameters SecureCRT 29 3 4 Power on of Switch 31 4 Technical Data 34 4 1 Overall Parameters 34 4 2 Laser Safety Class 35 4 3 Reliability Indicators 36 4 4 EMC Indicators 36 4 5 Safety Standards 36...
Page 7: ...mance high reliability high port density and convenience in installation to address users needs of enterprise class access or tandem low end switches 1 1 Product Model Description Table 1 1 S3200P S22...
Page 8: ...24T4X Front Panel 1 10 100 1000BASE T self adapting Ethernet port 2 10 100 1000BASE T self adapting Ethernet port status indicator 3 SFP Combo port 4 SFP port status indicator 5 USB port 6 Ethernet ma...
Page 9: ...wer module 1 status indicator PWR1 8 Pluggable power module 2 status indicator PWR2 9 Ethernet management port status indicator ACT LINK 10 10G SFP port 11 10G SFP port status indicator 12 Mode switch...
Page 10: ...ort 2 10 100 1000BASE T Ethernet port status indicator 3 Reset button 4 System status indicator SYS 5 Power indicator PWR 6 10G SFP port 7 10G SFP port status indicator 8 CONSOLE port 1 3 S3200P Serie...
Page 11: ...Guide Product Introduction NADDOD Pte Ltd x 1 3 2 S3200P 48T4X Figure 1 6 Schematic Diagram of S3200P 48T4X Back Panel 1 Grounding screw 2 Cooling fan 1 3 Cooling fan 2 4 Pluggable power module 1 PSU1...
Page 12: ...Back Panel 1 Grounding screw 2 AC power port 1 4 S3200P S2200 Series Port Description 1 4 1 Service Port Table 1 2 shows service ports of S3200P S2200 Series Table 1 2 Service Ports of S3200P Series...
Page 13: ...ed SFP optical module type 1000BASE X Downlink port S3200P 24T4X 24 4Combo 24 10 100 1000BASE T self adapting electrical interfaces 4 Combo SFPs All the electrical interfaces can provide POE PoE power...
Page 14: ...of the 1G SFP interface Table 1 4 Properties of 1G SFP Interface Property Description Connector type LC Optical interface properties Depend on the selected SFP module Operating mode Full duplex Standa...
Page 15: ...e 115200bit s Supported services Connect to character terminal Connect to serial port of local terminal could be PC and run terminal emulator on terminal Ethernet Management Port The front panel of S3...
Page 16: ...s can work normally on S3200P Series Switches Malfunction of any USB device should not be attributed to switch fault In such case please try USB devices from different manufacturers 1 5 S3200P S2200 S...
Page 17: ...ate of the port from different aspects The port mode indicator is designed to help users understand the current conditions of port status indicator The display status of the port mode indicator can be...
Page 18: ...e port is not linked up Green flash PoE mode only supported by S3200P 24T4X S3200P 48T4X Green always on Normal PoE power supply Green flash 1Hz The power consumption required by the device connected...
Page 19: ...e case of drop Good room ventilation must be ensured and the air holes of the switches must be kept unblocked The switches can works normally with correct voltage only Please confirm that the operatin...
Page 20: ...oose due to air shrinkage of the insulating spacer and static electricity is likely to be generated in dry environment to harm the electric circuits of switches excessively high temperature is more ha...
Page 21: ...please keep in mind AC power supply system is a TN system a one phase three line electric outlet with protective ground wire PE must be provided as AC socket to enable the filter circuit of equipment...
Page 22: ...E The switches of this series come without installation tools which must be prepared by users 2 2 Installation S3200P S2200 series switches can be installed in two ways Installing via front suspension...
Page 23: ...ssis Step 2 Install suspension loops and fix with screws Figure 2 1 shows how to install suspension loops on one side The installation of the other suspension loops is same Figure 2 1 Step 3 Install f...
Page 24: ...Step 1 Operators must wear anti electrostatic wrist strap Make sure that the anti electrostatic wrist strap contacts the skin properly and is grounded properly Step 2 Figure out the correct direction...
Page 25: ...Disconnect the power supply of switch Step 3 Hold power module handle and press the fixing device with one hand press the switch with another hand and gently pull out the power module along the slide...
Page 26: ...witch room Grounding connection with fire mains and lightning rod is not correct Figure 2 7 Schematic Diagram of Switch Grounding Wire Installation Description 1 Switch grounding terminal CAUTION Corr...
Page 27: ...ironment and Connecting Cables Figure 3 1 Building Local Configuration Environment via Console Port Step 1 Connect the USB plug of the provided cable to the serial port of a PC via which switch config...
Page 28: ...example of Windows XP Hyperterminal The method is as follows 1 Go to the hyperterminal window by tapping start program attached communication hyperterminal to create a new connection and the Connectio...
Page 29: ...ntrol null In other Windows operating systems bps may be expressed as Baud rate data flow control may be expressed as flow control 4 After parameter setting is completed click OK button and the Networ...
Page 30: ...Network Properties Interface CAUTION Please use the attached RJ 45 cable to avoid incompatibility 3 3 Setting up Port Parameters SecureCRT Step 1 Install SecureCRT software on PC Step 2 Setting up Se...
Page 31: ...Choose a serial number for PC an example of COM4 Figure 3 8 Serial Parameter Settings Serial Number Selection 4 Set Baud rate as 115200 data bits as 8 parity as null stop bits as 1 and flow control as...
Page 32: ...4 Power on of Switch After power on of switch the terminal shows device self checking information and the system turns to cmd such as switch after self checking is completed Type in commands to config...
Page 33: ...tion Guide Initial Startup after Power on of Switches NADDOD Pte Ltd 32 A Click the arrow pointed icon enter the path where the file naddod recovery x86_64 n6100 48x8c s r0 iso is saved in the pop up...
Page 34: ...es Installation Guide Initial Startup after Power on of Switches NADDOD Pte Ltd 33 A Click Start button choose DD Image Mode to write in in the pop up dialog box and click OK until the startup disk ma...
Page 35: ...nd Protocols 4 1 Overall Parameters Tables 4 1 and 4 2 show overall parameters of S3200P S2200 products Table 4 1 Overall Parameters of S3200P Series Item Parameters Outline dimension mm S3200P 24T4X...
Page 36: ...rameters of S2200 Series Item Parameters Outline dimension mm S2200 24T4X 440 W 160 D 43 6 H S2200 48T4X 440 W 240 D 43 6 H Maximum overall power consumption W S2200 24T4X 27 60 S2200 48T4X 37 60 Weig...
Page 37: ...Item Indicator requirement System availability 99 999 annual downtime not longer than 5 min Average annual return rate Lower than 1 5 MTTR Less than 2h MTBF 100000 hours 4 4 EMC Indicators S3200P S22...
Page 38: ...ed m s 20 Waterproof Requirements Onsite equipment storage requirement generally indoor storage must be guaranteed For indoor storage the storage place must be free of standing water and water seepage...
Page 39: ...radiation W s 1120 Thermal radiation W s 600 Wind speed m s 20 Waterproof Requirements All the following conditions must be met during transport The packaging box is intact Necessary rain shade is pr...
Page 40: ...cal Specification MEF 11 User Network Interface UNI Requirements and Framework MEF Technical Specification MEF 13 User Network Interface UNI Type 1 Implementation Agreement MEF Technical Specification...
Page 41: ...FC1349 Type of Service in the Internet Protocol Suite RFC2474 Definition of the Differentiated Services Field DS Field in the IPv4 and IPv6 Headers RFC2475 An Architecture for Differentiated Services...
Page 42: ...se B Place license under ftp server catalogue similar to installing system software C Type in the following commands via the serial port copy mgmt if ftp 192 168 1 11 d8860b0009d5 lic flash d8860b0009...
Page 43: ...er power on run checks as follows Step 1 Whether the power is normal Step 2 Whether the Console port cable is connected correctly If the problem persists after the checks above it is probably because...