C. BALANCE INPUTS CMRR
1.Volum set 0dB, Input 2V/10KHZ common mode sinwave signal at L channel Balance input,Connect a AC
Millivoltmeter to preout1L then adjust R565 for lowest output level.
2. Volum set 0dB,Input 2V/10KHZ common mode sinwave signal at R channel Balance input,Connect a AC
Millivoltmeter to preout1R then adjust R564 for lowest output level.
1-5