background image

 

Maintenance 

AVB9X is a professional machine. The warranty on these machine is of  1 year and regards the faults 
due to manufacturing defects. The faults due to improper use are not covered by warranty. For further 
details regarding warranty, contact the distributor supplying the machine. 
 
For a good preservation and a long duration of the machine, observe the following advice: 
1.  After each use, before storing the machine, remove all the water from the solution and the recovery 

tank. Put some liters of clean water into the solution tank and use the pump only, pressing the lever 
of the solution valve. This operation is useful to clean the internal parts of the pump, of the couplings 
and nozzles, removing the detergent residues. 

2.  After every use, store the machine in a cool and dry place with the cover open, to prevent humidity 

inside  the  recovery  tank  from  condensing  on  the  internal  parts  of  the  vacuum  motor,  therefore 
damaging  it.  The  damage  provoked  by  humidity  that  condenses  on  the  motor  (like  the  damage 
caused by the foam sucked by the motor) is not covered by warranty. 

3.  Periodically clean the water filter, extracting it from the machine and rinsing it under current water. 
4.  Eliminate the lime that in time deposits inside the hydraulic circuit of the machine, by putting some 

anti-lime solution in the solution tank and leave it for some hours. Then empty the tank and rinse. It is 
enough to perform this operation every 6-8 months. 

5.  Periodically check and clean the filter of the vacuum motor, which is located under the transparent 

circular cover of the upper tank. 

6.  Periodically check the consume of the carbon brushes of the vacuum motor. This check should be 

done after 500 working hours. 

7.  Periodically check also the carbon brushes of the water pump, after 500 working hours. 
8.  Check the consume of the carbon brushes of the brush motor, after 1500 working hours. 
9.  Worn-out carbon brushes may result in a damage to vacuum motor or pump, which are not covered 

by warranty. The check of carbon brushes should be done by technical assistance. 

10. Periodically check that the brush rotates without problems, eliminating the causes which prevent a 

free rotation. In case of difficulties, contact the technical assistance. 

 

 

Summary of Contents for AVB9X

Page 1: ...AVB9X USE AND MAINTENANCE MANUAL AVB9X PLEASE READ CAREFULLY BEFORE USING THE MACHINE Version 11 02 ...

Page 2: ...plosion if machine is used in an area where flammable vapors liquids or combustible dusts are present Never use flammable liquids or operate machine in or near flammable liquids vapors or combustible dusts WARNING Electrical Hazard Before putting the machine s plug in the current socket check that the voltage available is the same indicated on the label of the machines Be sure that the electrical ...

Page 3: ...covery tank In the long run the foam sucked by the motor can damage it In case of abnormal working very noisy motor not running pump extreme temperature rise or other suspicious signals switch off the machine and pull the plug out If foam or liquid escapes from the machine switch machine off immediately After using store the machine well cleaned in a cool and dry place The manufacturer cannot be h...

Page 4: ... upper tank is meant to contain the dirty water sucked from the carpet while the lower tank is meant to contain clean water and detergent The lower tank contains also the vacuum motor the brush motor and the pump The control panel is situated on the handle Vacuum head Clean water tank Recovery tank Clean water filling Recovery dome Spray nozzles float Brush Adjustment lever Spray knob Control pane...

Page 5: ...s equipped with the optional SMARTKIT it is possible to put in the tank just clean water and keep separate the chemical bottle See the specific manual for more details Attention wool carpet must be washed with cold water only 2 Insert the plug of the cable into a wall socket see Safety Regulations 3 Set to position I the switches of the vacuum motor the pump and the rotating brush 4 Set the spray ...

Page 6: ...rush to avoid the overload of the motor If this is not enough to avoid that the protection repeatedly intervenes you should contact the technical assistance The repeated intervening of the protection might result in faults which cannot be covered by warranty Keep an adequate safety distance from other people who could be run over by the machine Pay attention to any object that could be hit by the ...

Page 7: ...itches to position II In this way the solution pump always works and it is not necessary to keep pressed the control lever situated on the control panel 3 To spray water you need to press the lever situated on the handle of the accessory Working Method As regards the use as a self contained machine considering a rectangular surface we suggest you to proceed in parallel stripes spraying and sucking...

Page 8: ...caused by the foam sucked by the motor is not covered by warranty 3 Periodically clean the water filter extracting it from the machine and rinsing it under current water 4 Eliminate the lime that in time deposits inside the hydraulic circuit of the machine by putting some anti lime solution in the solution tank and leave it for some hours Then empty the tank and rinse It is enough to perform this ...