1. General

1.01

  The  NAC  PS0

1

  is  a  wall  mountable  power

supply that is designed to be used in applications 
where  48Vdc  power  (1.

3

5amp)  is  required.    This

 

product  is  ideal  for  use  with  assemblies  like  the 
NAC  WM02  and  WM04  Series  of  2  and  4

-

position

T1/HDSL  mountings.    The  PS0

1

  comes  with  a

bracket  for  wall  mounting,  or  can  rest  on  the  floor.  
The  PS0

1

  is  powered  via  a  standard  (6-foot)  3-

prong AC outlet, and provides power output via the 
attached 3 conductor power cord (5

-

7”).

1.02 

Whenever  this  document  is  revised,  the 

reason  for  revision  will  be  stated  in  this 
paragraph. 

1.03 

Features: 

  Impact resistant polycarbonate design 

  6-foot AC powering cable 

  6-foot, 3 conductor powering cable to power 

the apparatus case or other telecom 
equipment. 

  UL Listed 

2. Installation

2.01

  The  PS0

1

  is  designed  to  be  used  with 

Telecom  apparatus  cases  such  as  the  NAC 
WM02,  WM04  and  WM08  Series  2,  4  and  8-slot 
T1/HDSL  mountings  (or  their  equivalents).    The 
PS0

1

 can power up to 8 T1/HDSL modules.    The

 

PS0

1

 provides a mounting bracket for installations

 

where wall mounting of the PS0

1

 is required.

Wiring Connections 
2.02

 The PS0

1

 derives its power from a standard

3-prong AC wall outlet.  The PS0

1

 delivers power

to the assembly via 

a 5’7” 3-conductor power 

cable. Spade lugs on the end of the cable are 
connected to the appropriate screw terminal lugs 
(power terminal) on the assembly.  The powering 
connections are listed below in Table 1.

 

Pin (Spade Lug) 

Output Voltage 

Green 

GND 

Red 

-V 

Black 

+V 

2.03  The  following  warning  information  is 
required by the UL Safety Testing Laboratory: 

A.

 Never install telephone wiring during a 

lightning storm. 

B.

 Never install telephone jacks in wet locations 

unless the jack is specifically designed for wet 
locations. 

C. 

Use caution when installing or modifying 

telephone lines. 

D. 

Never touch un-insulated telephone wires or 

terminals unless disconnected at the network 
interface. 

General Description & Installation Practice 

PS0

1

 Rev. 

B

November 2014

 

680-xxxxx

 

1. General. . . . . . . . . . . . . . . . . . . . . . .  
2. Installation . . . . . . . . . . . . . . . . . . .
3. Inspection and Warranty . . . . . . . . . . .
4. Specifications . . . . . . . . . . . . . . . . .  




48Vdc, 1.

3

5Amp Wall-Mount Power

 

Supply

Model PS0

1

Figure 1.  PS0

1

 Power Supply

Table 1.  PS03 Power Connections 