Water Regulations Requirements

It is important to ensure that the water supplies to your taps and mixers are connected in accordance with the water
regulations (WRAS) requirements and good plumbing practice.
It is Wolseley’s recommendation and good plumbing practice that the supplies of hot and cold water to the products 

should be equal (balanced) pressures in order to provide a consistent flow. Supplies should be from a common source.
Either mains or tank fed. If supplies are not equal pressures then non return valves should be fitted (not supplied).

There products have been designed to function on all types of water of water systems. 
Please note: if a pump is to be installed to boost gravity supplies please refer to the pump manufactures instructions.
The hot and cold inlets for any of the products are hot on the left and cold on the right when viewed from the front of

the fitting. It is our recommendation and good plumbing practice that a service valve also should be installed up stream

in the inlet supply lines.

Pipe Connections

IMPORTANT. Before making any inlet pipe connections all supplies MUST be thoroughly flushed to remove any

debris.

Failure to do so could result in damage or low flow from the fitting.

It is a requirement of Byelaw 55 of the Water Fittings Byelaw Scheme that this function is undertaken before making
any pipe connections to supplies.

General Installation Notes

• Care must be taken during installation to prevent any risk of damage to the product or injury to installer.

• Installation must be carried out by a qualified and competent person and in accordance with the instructions supplied.

• Installations must comply with all Local and National Water Authority Regulations and Building/Plumbing

  Regulations.

• Ensure that you have read and understood all sections of this manual before installation.

Water Supply Pressures

All fittings have been designed to function under the following conditions:
• Minimum supply pressure: 0.2 bar
• Maximum supply pressure: 5.0 bar
Generous flow rates are achieved at pressures as low as 0.2bar. At high pressures it maybe necessary to reduce
excessive flow rates by fitting stop or servicing valves in the supply line before the mixer or tap. These stop valves

facilitate ease of maintenance should it be necessary.

Summary of Contents for B08916

Page 1: ...ridge Kitchen Mixer Instruction Warranty Leaflet Product code B08916 B08920 Tap head shown is for illustration purposes only Please keep this instructions for future reference and request of replacement parts ...

Page 2: ...s IMPORTANT Before making any inlet pipe connections all supplies MUST be thoroughly flushed to remove any debris Failure to do so could result in damage or low flow from the fitting It is a requirement of Byelaw 55 of the Water Fittings Byelaw Scheme that this function is undertaken before making any pipe connections to supplies General Installation Notes Care must be taken during installation to...

Page 3: ...ter flow for a few minutes to flush through the system Traditional deck sink mixer 1 Identify all components and check for completeness particularly before commencing installation 2 Fit the inlet legs to the tap body using the sealing washers 3 Fit the flange and anti rotational washers to the inlet leg 4 Install the fitting into the sink ensuring that the anti rotational washers are fitted betwee...

Page 4: ...tured to the highest of standards and should require little or no maintenance In the unlikely event of any spare part requirements please contact our free phone helpline number Free Phone Helpline Should you require any technical help in association with your Nabis products please call 0344 292 7062 with your query Warranty 5 Years For detail warranty information please visit our website plumbcent...

Reviews: