Nabis A05041 Instructions Manual Download Page 1

Concentric Thermostatic

Shower Valve

Instructions

Product code:
A05041

Please keep these instructions for future reference.

Summary of Contents for A05041

Page 1: ...Concentric Thermostatic Shower Valve Instructions Product code A05041 Please keep these instructions for future reference ...

Page 2: ...t by a qualified and competent person and in accordance with the instructions supplied Installations must comply with all Local and National Water Authority Regulations and Building Plumbing Regulations Ensure that you have read and understood all sections of this manual before installation Water Supply Temperature Pressures Hot Water Temperature Range Recommended 60 65 C Cold Water Temperature Ra...

Page 3: ...e construction Drill holes to suit required fixings Use wall plugs supplied as required 4 Secure wall bracket to the wall using the wall screws supplied 5 Fit the flange fixing nuts and copper olives over the inlet pipes 6 Insert the filters into the elbows 7 Make sure that the elbows align with the inlet pipes push valve body to the wall bracket and pipes with the outlet to the bottom and secure ...

Page 4: ...e diameter Inlet pipes not supplied 150 1 mm 20mm Valve body Temperature control handle On off and flow control handle Grub screw Copper olives Fixing nuts Wall screw Hexagonal key Flange Wall bracket Wall plug Filter Elbows Lever Wall plate ...

Page 5: ...ll screws supplied 5 Fit the flange fixing nuts and copper olives over the exposed inlet pipes 6 Insert the filters into the elbows 7 Make sure that the elbows alignment with the pipes push valve body to the wall bracket and pipes with the outlet to the bottom and secure with the two grub screws supplied using an 2 5mm hexagonal key at the same time See Fig 2 Carefully tighten securely the nuts of...

Page 6: ...checked if required using a thermometer If this temperature is incorrect you can reset it by the following 1 Turn the temperature handle to 38 C stop position 2 Remove cap then the screw then pull the temperature handle off the spindle 3 Without removing the limited ring turn the spindle of thermostatic valve carefully using pliers until the temperature is at the required level 4 Test again using ...

Page 7: ...r remove and clean the thermostatic cartridge Rinse thoroughly under cold water to remove any build up of limescale or debris Note Take note of the position of the thermostatic cartridge as it must be refitted in the same position 5 If necessary replace the thermostatic cartridge 6 Re fit the cartridge into the body and tighten the retaining nut using a suitable spanner 7 Re fit the on off and flo...

Page 8: ...ed to the highest of standards and should require little or no maintenance In the unlikely event of any spare part requirements please contact our telephone helpline number Telephone Helpline Should you require any technical help in association with your Nabis product please call 0344 292 7060 with your query Warranty 5 Years For detailed warranty information please visit our website www nabis co ...