background image

 

4 of 26

 

GT1400 Standard Single/Hurricane Single Folding Door Installation Manual 

www.NabcoEntrances.com

P/N C-00177 

Rev 6-14-21

Instruct the building owners and operator on the essentials of the operation of the door and this device. The owner should follow 

these instructions to determine whether the door is operating properly and should immediately call for service if there is any 

malfunction. All installation changes and adjustments must be made by qualified, NABCO trained technicians.

Note: As an Option, the GT-1400 Fold door can be certified to have a “Hurricane High Impact Compliant Version” manufactured 

to meet the High Velosity Hurricane Zone (HVHZ) requirements of the Florida building codes.

Section 3 .2 Objective

The GT-1400 Fold Door is designed to be installed within a Rough Opening of a Building. The door function is controlled by the Opus 

Control that offers many features to accommodate most installation options. This manual offers step by step instructions.  

A pedestrian Door that does not have Its glass sections installed at the Factory shall specify that 

the glazing material employed is to comply with the requirement in UL 325 par .30 .5 .1:

“The glazing material in both fixed and sliding panels of all sliding doors and in all 

unframed swinging doors shall comply with the requirements in the Performance 

Specifications and Methods of Test for Safety Glazing Material Used in Buildings, 

ANSI Z97 .1 . Glazing material for other pedestrian doors shall also comply with 

ANSI Z97 .1, except that single strength or heavier glass may be used for those 

portions of doors involving a glazed area of less than 1ft

2

 (0 .9 m

2

) and having no 

dimension greater than 18 in (457 mm)” .

CHAPTER 4: GETTING STARTED

Section 4 .1 Type of Fold Door

X

Standard Fold Door

X

Hurricane Fold Door

Section 4 .2 Folding Door Configuration

X

Installed within Rough Opening of Building

X

 Fold Door folds to the right or left

X

Bottom Load Header

X

Door Panels always fold toward the direction of breakout.

DN 2407

RH Single Fold

LH Single Fold

FS

FX

FX

FS

FX = Slide panel with breakout capabili es.

FS = Swing Panel with breakout capabili es.

Figure 1 

Door Configuration

Section 4 .4 Emergency Egress

DN 2408

FS

FX

Le  Hand

Right Hand

FX

FS

Le  Hand

Right Hand

CAUTION

Figure 1 

Emergency Egress

Summary of Contents for GT-1400

Page 1: ...ystems operational WARNING Table of Contents CHAPTER 1 WARNING LABELS 3 CHAPTER 2 GENERAL SAFETY RECOMMENDATIONS 3 CHAPTER 3 SCOPE 3 Section 3 1 To the Installer 3 Section 3 2 Objective 4 CHAPTER 4 GE...

Page 2: ...PTER 10 ADJUST FOLDING DOOR 13 CHAPTER 11 INSTALL WEATHERING 13 CHAPTER 12 GLAZING 13 SERVICE PARTS BAG P N A 00514 15 SERVICE PARTS OPUS CONTROL 16 SERVICE PARTS HEADER TOP HALF 17 SERVICE PARTS HEAD...

Page 3: ...ry or property damage Read study and understand the installation and operating instructions contained in or referenced in this manual before operating If you do not understand the instruction ask a qu...

Page 4: ...nstalled at the Factory shall specify that the glazing material employed is to comply with the requirement in UL 325 par 30 5 1 The glazing material in both fixed and sliding panels of all sliding doo...

Page 5: ...vot S le Door Hinge Jamb Tube Floor Pivot Thumbturn Lock Non Foldout side Keyed Lock Strike S le Sensors Floor Track Op on Sensor on Non Foldout side Figure 2 Standard Components Section 4 6 Parts of...

Page 6: ...rees DN 0987 Guide Channel Swing Out 90 Magne c Latch Dress Plate Rocker Switch 3 Remove screws used to secure the Dress Plate 4 Carefully lower the Dress Plate until the Rocker Switch wiring is expos...

Page 7: ...er manufacturer s certification document s Section 5 3 Secure Header to Rough Opening Verify that each Motor is connected to the Opus Control before inserting Pin or 1 8 Allen Wrench into Coupling Acc...

Page 8: ...so may result in serious personal or fatal injury When uncertain whether power supply is disconnected always verify using a voltmeter All high voltage electrical connections must be made by licensed e...

Page 9: ...lly OPENS to the RIGHT it is a right hand door DN 2056 Le Hand INTERIOR EXTERIOR Right Hand INTERIOR EXTERIOR Figure 8 Open the Fold Door Section 8 2 The Handing Harness Note The Handing Harness is us...

Page 10: ...b 2 Insert the Bottom Pivot Door Portion onto the Spacer Align screw holes to the Web Secure the Bottom Pivot Assembly to the Bottom Rail with X 2 1 4 20 x 1 1 4 Hex Screws when Spacers are used X 2 P...

Page 11: ...be pushed up toward the Header to allow clearance 5 Upright the Folding Door to slide the Bottom Pivot onto the Pivot Bearing located inside the Bottom Rail 6 Go back to the Top Web Lower the Spindle...

Page 12: ...Bearing 4 Tighten down the 4 1 4 20 x 3 4 inch Hex Head screws and 4 1 4 inch Star Washers Figure 16 Square Fold Door Panels DN 0993 SINGLE FOLD DOOR Gap Gap 5 Push on the Bar located in the middle o...

Page 13: ...Extrusion so the bent portion lays on top of the Door Hinge 2 Secure the weathering brush to Folding door panels with 6 x 1 2 inch self tapping color matched screws Figure 19 Weathering Extrusion is...

Page 14: ...r each marked spot place 1 Setting Block not provided by NABCO on top of the Base Glass Stops 5 Place the Glass Panel up against the Vinyl and sits on top of the Setting Blocks 6 Shift the Glass Panel...

Page 15: ...l it is flush to bot tom of Swing Door 3 T 00459 2 PHSMS 14x1 500L PHIL ZINC AB Secure Floor Pivot Assembly to Floor 4 T 00124 1 FHMS 1 4 20x0 875L PHIL ZINC Secure Pivot Base Bracket to Pivot Jamb Tu...

Page 16: ...88 Used on Brake Module FUSE 3 AMP 250V FAST 2AG AXIAL LEAD 4 T 00078 PHMS 10 32x0 625L PHIL ZINC 5 M 01072 HARNESS POWER MAGNUM OPUS 6 T 00282 22 inch WIRE 18 AWG 600V UL 1015 GREEN 7 M 01182 HARNESS...

Page 17: ...tandard Single Hurricane Single Folding Door Installation Manual Rev 6 14 21 P N C 00177 DN 0997 Service Parts HEADER TOP HALF Viewed from Non Break Out Side Sold as an Option 1 2 3 4 5 6 7 8 9 10 11...

Page 18: ...00823 LH OPERATOR SWGR W ENCODER LH CLUTCHLESS 8 T 00232 SHCS 10 24x0 875L ZINC 9 A 01053 OPER SWINGER W O MTR NO CLUTCH RH ROF 10 V 00090 MOTOR SHORT FRAME ENCODER DUOWEI 11 T 00092 WASHER 438 ID 1 0...

Page 19: ...d Single Hurricane Single Folding Door Installation Manual Rev 6 14 21 P N C 00177 DN 0998 Service Parts HEADER BOTTOM HALF Viewed from Non Break Out Side 1 2 3 4 5 6 7 8 9 10 11 12 14 15 16 17 18 19...

Page 20: ...74 NUT HEX NYLOCK 3 8 24 ZINC 12 M 01177 LOCK COVER PLATE BOTTOM 13 A 00758 SWITCHBREAKOUT 14 T 00391 FHMS 10 24x0 750L PHIL ZINC 15 T 00031 Black Zinc FHMS 10 32x0 500L PHIL UCUT T LOBE BKZN T 00184...

Page 21: ...21 of 26 www NabcoEntrances com GT1400 Standard Single Hurricane Single Folding Door Installation Manual Rev 6 14 21 P N C 00177 DN 0996 Service Parts SINGLE FOLD DOOR Viewed from Non Break Out Side...

Page 22: ...v 6 14 21 DN 0986 Bottom Lock Rod Used on Hurricane Doors Only Service Parts LEFT HAND SINGLE DOOR Viewed from Non Break Out Side 2 6 5 8 7 2 4 21 6 1 2 3 4 5 6 7 8 9 10 11 12 13 14 15 18 20 23 24 25...

Page 23: ...N C 00177 DN 0985 Bottom Lock Rod Used on Hurricane Doors Only 5 Service Parts RIGHT HAND SINGLE DOOR Viewed from Non Break Out Side 21 33 38 39 40 37 41 36 35 42 43 44 45 46 47 32 1 2 3 4 6 7 8 9 10...

Page 24: ...T 00043 FHMS 10 24x0 375L PHIL UNDERCUT ZINC 16 V 00123 Silver CYLINDER LOCK KEYED 204 V 70123 Dark Bronze CYLINDER LOCK KEYED 313 17 V 00116 Silver CYLINDER LOCK THUMBTURN 204 V 70116 Dark Bronze CYL...

Page 25: ...ROD ADAMS RITE 4016 A 00934 Hurricane Doors Only GUIDE LOCK UPPER HURRICANE UNIT 41 T 00176 Hurricane Doors Only FHMS 10 32x0 500L PHIL UCUT 23 PT ZINC 42 T 00037 SHCS 1 4 20x1 250L ZINC 43 A 01089 Er...

Page 26: ...26 of 26 GT1400 Standard Single Hurricane Single Folding Door Installation Manual www NabcoEntrances com P N C 00177 Rev 6 14 21 NOTES...