background image

GNDK / G90012-1 / G90030-1 / G90050-1 ve D01 BA⁄LANTI fiEMASI

11

7

8

KP

D5

D6

D7

D8

D9

D10

D11

D12

D13

D14

D15

D16

D17

D18

D19

D20

D21

D22

D23

D24

D25

D26

D27

D28

D29

D30

A

B

KP

TX

D57

D56

D55

D54

D53

D52

D51

D50

D49

D48

D47

D46

D45

D44

D43

D42

D41

D40

D39

D38

D37

D36

D35

D34

D33

D32

D31

wxyz

ENTER

DEL

tuv

pqrs

mno

jkl

ghi

def

abc

G90012-1

G90012-1

Kap› zil butonu

G90030-1

G90050-1

9

10

11

12

D 01

28272219 A  B

GNDK

G90012-1

G90012-1

DA‹RE-1

DA‹RE-2

DA‹RE-3

DA‹RE-4

Kap›c› Telefonu, 57. daire olarak belirlenmifl ve D01’in D57ç›k›fl›, G90050-1 santralinin 11
numaral› klemensiyle birlefltirilerek, G90030-1 kap›c›s›n›n 11 numaral› girifline verilmifltir.
Panelden 57. daire aran›rsa kap›c› telefonu çalacakt›r. Siz kaç›nc› daireyi kap›c› telefonu
olarak belirlemek istiyorsan›z D01 in ilgili ç›k›fl›na ba¤layabilirsiniz. Örne¤in, D32 ç›k›fl› ile
gerekli ba¤lant›lar› yap›p, panelden 32 numara aran›nca kap›c› telefonunuz çalacakt›r.

3

4

22

21

20

19

18

17

28

27

24

23

L

N

Kap›c› Telefonu

28

27

D1

D2

D3

D4

Summary of Contents for GNDK

Page 1: ...uch chemicals as powerful detergent and cleaners To clean the device use soap cleaners and rub up to product 1 G90012 1 G90030 1 G90050 1 wxyz ENTER DEL tuv pqrs mno jkl ghi def abc GNDK D01 GENERAL F...

Page 2: ...utton Record To register name and number to guide Door Password To change door opener password Administrator Password To change Administrator Password you can choose these selections by pressing Enter...

Page 3: ...K ADMINISTRATORPASSWORD ISCHANGED 6 Speed Call from Panel While main screen is on display Screen 1 or Screen 2 speed call screen is displayed by using keypad Screen 15 After flat number is entered and...

Page 4: ...s and complete the mounting by taking away the NA DE Key FIGURE 1 8 X Microphone Audio Setting Y LCD contrast setting Z Speaker audio setting After completing the connections of the system and gave el...

Page 5: ...9 Connect this terminal directly to terminal 19 in Central unit Provides audio connection from Central unit Terminal 22 Connect this terminal directly to terminal 22 in Central unit Provides 15VDC fro...

Page 6: ...e out the cover screws as shown above Fit the panel to wall surface by apparatus which is given in the package Pass the cable through the hole as shown above Put the cover after all connections are do...

Page 7: ...n from Central unit N Connected to N terminal Provides data transfer from panel to doorphone 1 2 NOTE Figure 1 shows the meaning of buttons Open the top cover by screw driver as shown in figure 2 Moun...

Page 8: ...connection from Central unit Terminal 11 Connect this terminal directly to terminal 11 in Central unit Provides data transfer from Central unit Please refer G90050 1 connection diagram 1 2 NOTE Figur...

Page 9: ...10 Data connection for door keeper phone Terminal 11 N signal connection for door keeper phone Terminal 12 GND output Terminals 3 and 4 Door opener dry contact output KP KP input which comes from D01...

Page 10: ...N DIAGRAM 10 G90012 1 G90012 1 FLAT 2 FLAT 3 17 22 19 21 20 18 G90012 1 DOOR BELL BUTTON DOOR BELL BUTTON DOOR BELL BUTTON FLAT 1 GTHP 04 DOOR KEEPER TELEPHONE 3 4 28 27 24 23 22 21 20 19 18 17 L N Do...

Page 11: ...FLAT 1 FLAT 2 FLAT 3 FLAT 4 Door keeper is designated as 57th flat and D57 output of D01 is connected terminal block 11 port of G90050 1 central unit and given input of 11 port of G90030 1 If 57th fl...

Page 12: ...minal block 27 GND connection It must connect to G90050 1 Central Unit s 27 number terminal block D1 D2 D57 It must connect to G90012 1 s N inputs A ve B It must connect to A and B outputs on panel GN...

Page 13: ...3 28 27 24 23 28 27 24 23 28 27 24 23 28 27 27 UPS 220VAC 50 60Hz INPUT OUTPUT 220VAC 50 60Hz If system is wanted to be work on power cut etc Problems UPS must be connected to system input as shown in...

Page 14: ...there are 8 different coloured cables Cables must be connected as Number 28 is by two number 27 is by three numbers 24 and 23 are by one This way system will work much more effective Door Bell Button...

Page 15: ......

Page 16: ...KK G90050 1_131224_EN_00...

Page 17: ...1 G90030 1 G90050 1 wxyz ENTER DEL tuv pqrs mno jkl ghi def abc GNDK D01 S STEM N GENEL ZELL KLER Rehberli ve LCD ekranl digital zil paneli GNDK l ve D01 li sistemler Digital zil panelinden ifreli d k...

Page 18: ...YIT Rehbere numara ve isim kaydetmek i in KAPI FRES Kap otomati i ifresini de i tirmek i in Y NET C FRES Y netici ifresini de i tirmek i in se eneklerinden birine gelip Enter tu una basarak istedi ini...

Page 19: ...14 ENTER SE DEL GER Y NET C FREN ZDE M T R 6 Panelden H zl Arama Yapmak Ekranda ana ekran g r nt s varken Ekran 1 veya Ekran 2 tu tak m kullan ld nda h zl arama ekran g r nt lenir Ekran 15 Aranacakda...

Page 20: ...yerine takt ktan sonra yukar ya do ru itiniz Anahtar yuvadan kartarak montaj tamamlay n z X Mikrofon ses ayar Y LCD kontrast ayar Z Hoparl r ses ayar EK L 1 8 Sistemin gerekli ba lant lar n yap p elek...

Page 21: ...ce yanan g nd z s nen LED li isimlik Hoparl r ses ayar Mikrofon ses ayar 17 Numaral Klemens Santraldeki 17 numaral klemense ba lanmal d r Panele 30VDC voltaj gelir 19 Numaral Klemens Santraldeki 19 nu...

Page 22: ...ile birlikte verilen montaj elemanlar yard m ile duvar veya sert y zeye monte ediniz ekilde g r ld gibi kabloyu ba lant yuvas ndan ge iriniz ekilde g r ld gibi kablo ba lant lar n yapt ktan sonra s k...

Page 23: ...ar na ba lanmal d r Panelden telefona veri transferi sa lan r 1 2 NOT ekil 1 de telefon zerindeki butonlar n a klamalar g r lmektedir ekil 2 de g r ld gibi bir tornavida yard m ile telefon st kapa n a...

Page 24: ...ldeki 11 numaral kelmense ba lanmal d r Santral ve telefon aras nda veri transferi sa lan r Ba lant ekli santral G90050 1 ba lant emas nda g sterilmi tir 1 2 NOT ekil 1 de telefon zerindeki butonlar n...

Page 25: ...numara Kap c telefonu veri ba lant s 11 numara Kap c telefonu N sinyali ba lant s 12 numara GND k 3 ve 4 numara Kap otomati i kuru kontak k KP D01 den gelen KP giri i 17 numara Panel 30V beslemesi 18...

Page 26: ...9 10 11 12 GTHP04 G90012 1 G90030 1 G90050 1 BA LANTI EMASI 10 G90012 1 G90012 1 DA RE 2 DA RE 3 17 22 19 21 20 18 G90012 1 Kap zil butonu Kap zil butonu Kap zil butonu DA RE 1 GTHP 04 Kap c Telefonu...

Page 27: ...10 11 12 D 01 28272219 A B GNDK G90012 1 G90012 1 DA RE 1 DA RE 2 DA RE 3 DA RE 4 Kap c Telefonu 57 daire olarak belirlenmi ve D01 in D57 k G90050 1 santralinin 11 numaral klemensiyle birle tirilerek...

Page 28: ...aral klemensine ba lanmal d r 27 GND ba lant s d r G90050 1 santralinin 27 numaral klemensine ba lanmal d r D1 D2 D57 G90012 1 ubelerinin N giri lerine ba lanmal d r A ve B Paneldeki GNDK A ve B k lar...

Page 29: ...3 28 27 24 23 28 27 27 UPS 220VAC 50 60Hz INPUT OUTPUT 220VAC 50 60Hz Elektrik kesintisi vb problemlerde sistemin belirli s re zarf nda al maya devam edebilmesi isteniyor ise sistem giri ine UPS ekild...

Page 30: ...8 adet farkl renklerde kabo kar Hangi t r kabloyu kullan rsan z a a daki ekilde g sterildi i gibi 28 numara ikili 27 numara d rtl 24 numara tekli 23 numara tekli olarak ekilmelidir Bu sayede sistemin...

Page 31: ......

Page 32: ...KK G90050 1_140611_TR_00...

Reviews: