Operating voltage
Detection angle
Mounting height
Detection range
Time settings
Lighting load
Emergency Lighting Load
Battery type
Battery opr. time
Protection class
Opr. temperature
Power consumption
(Active/Stand-by)
SPECIFICATIONS
10410
29 lm
3.6V 1000mAh Ni-Cd rechargeable battery
2 hours
10710
-
-
-
10W / 1W
230-240V~ 50/60 Hz
360°
2.8 m.
9 m.
10 sec.
±
1 sec. / 5 min.
±
10 sec.
490 lm
IP20
Class I
-20 °C ~ +40°C
10.3W / 1.3W
“OFFERS ENERGY SAVING FEATURE’’
TROUBLESHOOTING
MALFUNCTION
CAUSE
SOLUTION
• LEDs are off
• There is no
electricity on the
device
• LEDs are on
Continuously
• Changing detection
area in device
• LEDs do not turn
ON
• Day light adjustment set to
night-time mode during daytime
operate
• LEDs are defected
• Power switch off or no electricity
• Fuse faulty
• Fuse switch off or fuse faulty
• Connection faulty.
• Continuously movement in
detection area
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.
• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.
• There is energy
• No movement
• Battery is low
• Control daylight setting and
re-adjust
• Call technical servise
• Check the electricity and power
on.
• Change the fuse.
• Check the fuse if necessary use
a new fuse.
• Check the connection cables.
• Check the detection area.
• Avert it is being detection.
• Change detection area, change
site of installation.
• Change site of installation or
keep the reasons away.
• Change site of installation.
• Turn of the energy
• Make it see the movement
• Charge battery / Change battery
Walking targential to the sensor
(normal detection range)
Walking directly to the sensor
(lower detection range)
Figure 1
DETECTION AREA
Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature, mounting style and mounting place. Temperature is very important for
operation for motion sensor like all electronic devices. Environment temperature may also cause
decrease of detection range. Detection range given is determined at +20°C. If the weather is
hot, it will decrease.
The maximum detection range can be realized when walking tangential to the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. The detection distace of 10710-10410 models is 9 m as diameter and 4,5
m as radius.
GUARANTY
We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice (date of purchase and
dealer’s stamp) to the appropriate Service Center.
SETTING
(e)
(d)
+
-
+
-
(e) Time setting
Light ON time can be adjusted continuously from “10 sec.
±
1 sec. / 5 min.
±
10 sec.” If you turn
the knob
clockwise
device will operate at minimum time. (10 seconds)
Control dial set to - = Shortest time (10 sec.
±
1 sec.)
Control dial set to + = Longest time (5 min.
±
10 sec.)
(d) Daylight setting
The sensor’s response threshold can be infinitely varied from 2-2000 lux.
If you turn the knob
anticlockwise
device will operate at dark.
Control dial set + = daylight operation approx. 2000 lux.
Control dial set - = night-time operation approx. 2 lux.
NOTE: Device will automatically make its own offset by checking environment for approximately
5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.
10710-10410
360° CEILING ARMATURE WITH MOTION SENSOR
AND EMERGENCY LIGHTING
Detection range is determined for temperature of +20°C
DETECTING RANGE
SYSTEM COMPONENTS
(a) Glass Cover
(b) Main frame
(c) Mounting holes
(d) Daylight setting nobe
(e) Time setting nobe
(f) Battery socket
[email protected] • www.na-de.com.tr
(a)
(b)
(L) = Line conductor
(N) = Neutral conductor
Connect line (L) and neutral (N) to the terminal
block.
Battery
socket
(c)
(c)
(c)
(c)
(e)
(d)
(f)
AREA OF USING
• In building entrances, stairs
• In long halls within flats
• In places required within flats
• In Parking garages
• In reguired places of hotels
• In schools, hospitals and gas stations
GENERAL SECURITY CAUTIONS
• Take out the product from orginal package and control if there is any damage of transportation
and general view of the product
• Don't use the product for out of purpose
• Keep away from the wather and moist areas
• Keep away from dust and dirt
• Don't use with high voltage
• Don't use fluid on good
• Protect from impact
• As using 230-240V~ only specialist electricians must install and apply
• 3.6 V rechargeable battery must be used, otherwise it may explode
•
BATTERY IS OUT OF GUARANTY
CAUTIONS FOR INSTALLATION AND USAGE
• Charge the battery 5 hours before operating. Battery will be active when power is off.
• Installing must be applicable for national wiring and electrical operating conditions.
• Turn off the network before mounting.
• Don't mount the product near to radiator and moist areas.
• Place the product horizontal to celling.
• Use 6A fuse in product.
• Factory setting : Daylight adjustment is at the darkest, time adjustment is at the shortest.
• Setting can be made 10-15 seconds afert relasing of the power.
• Time and daylight setting can be made in day and night.
• Don't change time and daylight settings abrupty.
• Don't make a second setting before seeing result of the first setting of time and daylight.
• After you determine right setting of the daylight you can adjust the time as you need for
daylight setting, increas untill reaching to the best result by starting the minimum.
• Use only dry cloth for cleaning.
• Don't mount near to device that can change the temperature abruptly (radiator, oven, fan,
refrigerator etc.) and protect from sunshine.
• Beeing trees, bushes etc. In the coverage area may cause to detection errors.
KK-10710_10410_150414_EN_00
2.8 m.
9 m.
4,5 m.
4,5 m.
360°
GB
Line
Neutral
Complies with ROHS Regulation Directive
2002/95/EC
TS EN 60669-2-1