background image

(d)

(e)(f)

(g)

(h)

Operating voltage
Angle of coverage
Mounting Height
Detection Range
Time setting
Lighting load
Protection class
Opr. temperature
The amount of light emitted (emergency mode)
Emergency lighting duration
Battery
Power consumption (Stand-by)

230-240V~   50/60 Hz
360°
2.8 m.
9 m.
10 sec. 

±

 1 sec. / 5 min. 

±

 10 sec.

Max 2x25W E27 bulb
IP20                 Class l
-20°C ~ +40°C
40 Lumen
2 hours
3x1.2V 1000mAh ni-mh AAA
1W

SPECIFICATIONS

00777

00777

CEILING ARMATURE WITH 360° MOTION SENSOR

DETECTING RANGE

SYSTEM COMPONENTS

DETECTION AREA :

Detection area of motion sensors depends on the angle between PIR detector and moving
direction, temperature (power of lamps changes this temperature), mounting style and mounting
place. Temperature is very important for operation for motion sensor like all electronic devices.
Using higher value of loads written on manuals and packages will decrease temprature inside
the device when using Ceiling Armatures with Motion Sensor. As a result detection range will
decrease and may cause defect of electronic components. Environment temperature will also
cause decrease of detection range. Detection range give is determined at +20°C. If the weather
is hot, it will decrease.

Walking targential to the sensor

(normal detection range)

Walking directly to the sensor

(lower detection range)

Figure 1

The maximum detection range can be realized when walking tangential to  the sensor (figure1)
When walking directly to the sensor detection range will be low. Because you will not be able
to cut vertical areas. Detection range of Motion Sensors is 9 meters as diameter, 4,5 meters
as radius.

GUARANTY

We will remedy defects caused by material flaws or manufacturing faults. The warranty will be
met by repair or replacement at our own discretion. The warranty shall not cover damage to
wear parts, damage or defects caused by improper treatment or maintenance. Further
consequential damage to other object is excluded.
Claims under the warranty will only be accepted if the unit is sent fully assembled and well
packed complete with a brief description of the fault, a receipt or invoice (date of purchase and
dealer’s stamp) to the appropriate Service Center.

USAGE AREAS

• At the building entrances, stair vestibules.
• At the long halls within the flats.
• At the places required within the flats.
• At the parking garage.
• At the requisite locations within the hotels.
• At the schools, hospitals and oil filing station.

GENERAL SECURITY CAUTIONS

• Take off the original package and control if there is any damage of transportation and general
view of the product.
• Do not use the product at cross purposes.
• Keep it away from water and moist areas.
• Do not use the product at dusty, dirty and rusty places.
• Do not supply high voltage.
• Do not apply any liquid.
• Protect from any stroke.
• Using 230-240V~ voltage is so dangerous that only the specialist electricians must install
and apply.

CAUTIONS FOR INSTALLATION AND USAGE

• Installing must be carried out professionally in accordance with applicable national wiring and
electrical operating conditions.
• Turn of the network before mounting.
• Do not mount the product near the radiator and moist areas.
• Place the product horizontal to the ceiling.
• Fix the bulbs before operating.
• Use 6A fuse the supply input.
• Factory setting; daylight adjustment is at darkness, time adjustment is at the shortest.
• Setting can be made 10 - 15 second after the releasing of the power.
• Time and daylight setting can be made during the day or night.
• Do not change the time and daylight settings abruptly.
• Do not make a second adjustment before you get a result from the first setting of the time
and daylight.
• After you determine the right setting of the daylight, you can arrange the time as you need.
• The best result for the daylight setting can be obtained by adjusting the minimum. And that
you can find the correct setting for sensitivity incrementally.
• When a cleaning needed for the glass, take of carefully and clean with a dry rag.
• Avoid mounting the detector close to objects that can cause rapid temperature changes such
as heaters, fans, refrigerators and ovents etc, and prevent the detector from point-blank
sunshine.
• It can cause the device operate inaccurately if there is tree, brushes etc. in the coverage area.
• The product has Y type connection.

Neutral line

Phase line

(L) = Line conductor
(N) = Neutral conductor
      = GND conductor
Lamps must be connecte
before power is turned-ON.

(a)

(b)

(c)

(a) Clamping washer
(b) Glass Cover
(c) Ceiling mount
(d) Ceiling mount screw
(e) Daylight setting nobe
(f)  Time setting nobe
(g) Lamp holder (E27 porcelain)
(h) Battery socket

As shown in figure, firstly open the string by
turning counter clockwise and take off the
glass. Mount the ceiling from places which
shown in figure (c) and figure (d). And first
will connect ground connection, than connect
connector as shown in electrical connection
part. Then lay the glass its place and fasten
up the glass byconstricting the string.

(e) Daylight setting
The sensor’s response threshold can be infinitely varied from 2-2000 lux. If you turn the knob
clockwise device will operate at dark.

     Control dial set  = daylight operation approx. 2000 lux.
     Control dial set  = night-time operation approx. 2 lux.

(f) Time setting
Light ON time can be adjusted continuously from “10 sec. 

±

 1 sec. / 5 min. 

±

 10 sec.” If you turn

the knob anticlockwise device will operate at minimum time. (10 seconds)

Control dial set to  - = Shortest time (10 sec. 

±

 1 sec.)

Control dial set to + =  Longest time (5 min. 

±

 10 sec.)

NOTE: 

Device will automatically make its own offset by checking environment for approximately

5 minutes after the first installation. After this period device will operate normally. If you think
the device does not operate normal in first installation, please wait for 5 minutes and start to
test again. Be sure that there is no motion by this period.

ELECTRICAL CONNECTION

KK-00777_160303_EN_00

“OFFERS ENERGY SAVING FEATURE’’

The sensing distance is provided according to the +20 °C ambient conditions.

SETTING

www.na-de.com.tr • [email protected]

‹stanbul Deri Organize Sanayi Bölgesi Tufle Sok. No:8

M1-8 Özel Parsel 34953 Tuzla / ‹STANBUL - TÜRK‹YE

GB

2.8 m.

9 m.

   4,5 m.

   4,5 m.

360°

TROUBLESHOOTING

MALFUNCTION

CAUSE

SOLUTION

• Lamp is off

• There is no
electricity on the
device

• Continuously
lamp is on

• Change
perception
area in device

• LED’s do not
turn ON

• Daylight adjustment set to
night-time mode during daytime
operate
• Bulb faulty or there is no
connection
• Power switch off or no electricity
• Fuse faulty

• Fuse switch off or fuse faulty

• Connection faulty.

• Continuously movement in
detection zone
• Cars on the streets are being
detected.
• Wind, rain, snow is moving to the
trees & bushes or open windows in
detection zone.

• Sudden temperature changes due
to weather(wind, rain, snow) or the
air expelled from fans.
• Different ambient temperatures.

• There is energy
• Battery is low

• Control daylight setting and
re-adjust
• Fit the bulb into the lamp holder,
if it still does not operate, change
the bulb.
• Check the electricity and power on.
• Change the fuse.

• Check the fuse if necessary use
a new fuse.
• Check the connection cables.

• Check the detection zone.

• Avert it is being detection.

• Change detection zone, change
site of installation.

• Change site of installation or
keep the reasons away.

• Change site of installation.

• Turn of the energy
• Charge battery / Change battery

Complies with ROHS Regulation Directive

2002/95/EC

3

TS EN 60669-2-1
TS EN 60598-2-1

Reviews: