background image

SER-485-FXC_0710 R1 

 

 

 

 

 

 

 

 

 

 

 

 

 

 

N-Tron Corp. 

820 S. University Blvd. Suite 4E, Mobile, AL 36609 

PH: 251-342-2164 · FAX: 251-342-6353

 

1

1

.

.

 

 

C

C

h

h

e

e

c

c

k

k

 

 

f

f

o

o

r

r

 

 

R

R

e

e

q

q

u

u

i

i

r

r

e

e

d

d

 

 

H

H

a

a

r

r

d

d

w

w

a

a

r

r

e

e

 

 

  SER-485-FXC Fiber Optic Converter 

  This Quick Start Guide 

  Additional Items Required but not included 

o

  A 10 to 48 VDC Power Supply. 

o

  Serial Cable 

o

  Multi-Mode Fiber Optic Cable with ST 

Connectors (62.5 / 125 micro-meter). 

 

2

2

.

.

 

 

I

I

n

n

f

f

o

o

r

r

m

m

a

a

t

t

i

i

o

o

n

n

 

 

 

 

U

U

L

L

 

 

C

C

l

l

a

a

s

s

s

s

 

 

1

1

 

 

D

D

i

i

v

v

 

 

2

2

 

 

1. Power, input /output (I/O) wiring must be in 

accordance with Class 1 Division 2 wiring methods 
[Article 501.10(B) of the National Electric code, 
NFPA70] and in accordance with the local authority 
having jurisdiction. 

2. Maximum ambient air temperature 80° C. 
3. 

WARNING – EXPLOSION HAZARD: 

SUBSTITUTION OF COMPONENTS MAY IMPAIR 
SUITABLITY FOR CLASS 1, DIVISION 2. 

4. 

WARNING –

 

EXPLOSION HAZARD: 

WHEN IN 

HAZARDOUS LOCATIONS, TURN OFF POWER 
BEFORE REPLACING OR WIRING MODULES 

5. 

WARNING – EXPLOSION HAZARD: 

DO NOT 

DISCONNECT EQUIPMENT UNLESS POWER HAS 
BEEN SWITCHED OFF OR THE AREA IS KNOWN 
TO BE NON-HAZARDOUS. 

6. 

WARNING –

 THIS APPARATUS IS SUITABLE FOR 

USE IN CLASS 1 DIVISION 2, GROUPS A, B, C, 
AND D, OR UNCLASSIFIED AREAS

 

6

6

.

.

 

 

P

P

o

o

w

w

e

e

r

r

 

 

C

C

o

o

n

n

n

n

e

e

c

c

t

t

i

i

o

o

n

n

 

 

1. Power requirements are10 to 48 VDC @ 0.2A Follow polarity 
shown on label.  

7

7

.

.

 

 

W

W

i

i

r

r

i

i

n

n

g

g

 

 

E

E

x

x

a

a

m

m

p

p

l

l

e

e

s

s

 

 

RS-485 2-Wire 
 

 

 

 

 
 

 
 
 
 
 

 

 

 

 
 
 
 
 
 
 
 
 
 
 
 
 
 
 
 

Put  

 
 
 
 
 
 
 

 

Quick Start Guide 

SER-485-FXC 

Triple Isolated RS-232 to 

Multi-Mode Fiber Converter 

3

3

.

.

 

 

F

F

r

r

o

o

n

n

t

t

 

 

P

P

a

a

n

n

e

e

l

l

,

,

 

 

S

S

w

w

i

i

t

t

c

c

h

h

e

e

s

s

,

,

 

 

T

T

e

e

r

r

m

m

i

i

n

n

a

a

l

l

 

 

B

B

l

l

o

o

c

c

k

k

 

 

 

 

 

 

 

4

4

.

.

 

 

 

 

R

R

S

S

-

-

4

4

2

2

2

2

/

/

4

4

8

8

5

5

 

 

M

M

o

o

d

d

e

e

,

,

 

 

T

T

e

e

r

r

m

m

i

i

n

n

a

a

t

t

i

i

o

o

n

n

 

 

&

&

 

 

B

B

i

i

a

a

s

s

 

 

D

D

I

I

P

P

 

 

S

S

w

w

i

i

t

t

c

c

h

h

 

 

S

S

e

e

t

t

t

t

i

i

n

n

g

g

s

s

 

 

 

 

 
 

5

5

.

.

 

 

R

R

S

S

-

-

4

4

2

2

2

2

/

/

4

4

8

8

5

5

 

 

T

T

i

i

m

m

e

e

 

 

O

O

u

u

t

t

 

 

 

 
Pre-defined timeouts are set using switches 8 through 11. 
Resistor selectable baud rates are set by inserting a 
through-hole resistor (R-9) on the circuit board. 
  
Timeout selections are equal to one character time at the 
indicated baud rate. Setting the converter to 9600 will 
generally work at 9600 and higher baud rates. 

In RS-422 

mode, timeouts are not required.  

 

 

Reviews: