Regulatory Approvals: 
 
Safety: 

Suitable for use in Class I, Division 2, Groups A, B, C and D Hazardous Locations, or Nonhazardous 

 

Locations only. 

 

EMI:  

EN 61000-6-4, EN 55011 - Class A

 

FCC Title 47, Part 15, Subpart B - Class A 
ICES-003 – Class A 
 

EMS: 

EN 61000-6-2

 

IEC 61000-4-2 (ESD) 

 

IEC 61000-4-3 (RS) 

 

IEC 61000-4-4 (EFT) 

 

IEC 61000-4-5 (Surge) 

 

IEC 61000-4-6 (Conducted Disturbances) 

 

GOST-R Certified. 

Summary of Contents for 102MC

Page 1: ... Revised 2011 04 15 1 100 Series Media Converter Industrial Ethernet Switches User Manual Installation Guide ...

Page 2: ...edia Converter and Ethernet Switch Installation Guide 102MC XX 105TX 106FX2 110FX2 XX YY 102MCE XX YY 105TX SL 108TX 111FX3 XX YY 104TX 105FX XX 108TX HV 112FX4 XX YY 105FXE XX YY 114FX6 XX YY 116TX Where XX ST or SC and YY 15 40 or 80 ...

Page 3: ...tion contained in this document is subject to change without notice N TRON Corp makes no warranty of any kind with regard to this material including but not limited to the implied warranties of merchantability or fitness for a particular purpose In no event shall N TRON Corp be liable for any incidental special indirect or consequential damages whatsoever included but not limited to lost profits a...

Page 4: ...hing else to the unit Units not properly grounded may result in a safety risk and could be hazardous and may void the warranty See the grounding technique section of this user manual for proper ways to ground the unit WARNING Do not operate the equipment in a manner not specified by this manual ENVIRONMENTAL SAFETY WARNINGS WARNING Disconnect the power and allow to cool 5 minutes before touching E...

Page 5: ... field installed conductors For the 116TX Use 105 C rated copper wire 0 22Nm 2 inch lbs tightening torque for field installed conductors 6 WARNING Install only in accordance with Local National Codes of Authorities Having Jurisdiction 7 Class I Div 2 Installations require that power connections must be current limited at the power source with an in line fuse rated at 0 5A 8 Class I Div 2 installat...

Page 6: ...X models and up to 80 Kilometers for the FXE models without the use of repeaters The 110FX2 FXE2 has 8 10 100BaseTX RJ 45 auto sensing ports and 2 100BaseFX ports with ST or SC connectors capable of 2 Kilometers of 100 Mb communications for the FX models and up to 80 Kilometers for the FXE models without the use of repeaters The 111FX3 FXE3 has 8 10 100BaseTX RJ 45 auto sensing ports and 3 100Base...

Page 7: ...and store the packaging in a safe place File any damage claims with the carrier CLEANING Clean only with a damp cloth INSTALLATION Read the following warning before beginning the installation WARNING Never install or work on electrical equipment or cabling during periods of lightning activity Never connect or disconnect power when hazardous gasses are present LASER SAFETY MCE and FXE models only 4...

Page 8: ...at the bottom of the unit and apply downward force on the clip until it disengages from the bottom of the unit from the DIN rail Rotate the bottom of the unit towards you and up at an approximate 15 upward angle to completely remove the unit To install the metal clip units to 35mm industrial DIN rail place the top edge of the included mounting bracket on the back of the unit against the DIN rail a...

Page 9: ... Our Universal Rack Mount Kit P N URMK may be used to mount the 100 Series enclosures to standard 19 racks and our Panel Mount Assembly P N 1000 PM may be used to mount the metal clip versions of the 100 Series enclosures to a panel or any other flat surface NOTE the 1000 PM will only work with the factory installed MDR metal clip options and it is not acceptable for the 116TX units ...

Page 10: ...om Top to Bottom SPD Speed LED LNK ACT Link Activity LED RJ45 Ports Auto sensing 10 100BaseT Connection Green LED lights when Power is connected NOTE The top LED indicates Link Activity LNK ACT and the lower LED indicates Speed SPD status ...

Page 11: ...ption ON Power is Applied OFF Power is OFF LNK ACT ON Link established no Activity on cable BLINKING Link established Activity on cable OFF No link activity on cable SPD ON LINK is 100Mbps OFF Link is 10Mbs APPLYING POWER 102MC 104TX 105TX 105FX 106FX2 108TX and 116TX Power Connector Top View ...

Page 12: ... Note Either V1 or V2 can be connected to power for minimal operation For redundant power operation V1 and V2 plugs must be connected to separate DC Voltage sources Use wire sizes of 16 28 gauge The power cord should be limited to less than 10 meters in order to ensure optimum performance Recommended 24V DC Power Supplies similar to 100 240VAC N Tron NTPS 24 1 3 DC 24V 1 3 105TX SL Top View Unscre...

Page 13: ...vided on the back face of the enclosure In the event the provided grounding screw has been lost care should be taken to limit the penetration of the outer skin by less than 1 4 Failure to do so may cause irreversible damage to the internal components of the switch Note Ensure the power supply is grounded properly before applying power to the grounded switch This may be verified by using a voltmete...

Page 14: ...o use fully shielded cables terminated to chassis ground at both ends in systems void of low level analog signals RJ45 CONNECTOR CRIMP SPECIFICATIONS Please reference the illustration for your Cat5 cable specifications 105TX SL DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POINT METALLIC DIN RAIL CLIP DRAIN WIRE WITH LUG CONNECTING SWITCH CHASSIS TO KNOWN GOOD GROUNDING POI...

Page 15: ...nd station Verify that the LNK LED s are ON once the connection has been completed To connect any other port to another Switch or Repeater use a standard Cat5 straight through or crossover cable Warning Creating a port to port connection on the same switch i e loop is an illegal operation and will create a broadcast storm which will crash the network TROUBLESHOOTING 1 Make sure the Power LED is ON...

Page 16: ...radio communications Operation of this device in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his her own expense INDUSTRY CANADA This Class A digital apparatus meets all requirements of the Canadian Interference Causing Equipment Regulations Operation is subject to the following two conditions 1 this device may n...

Page 17: ...Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Fiber Singlemode 7 10 125µm Fiber Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connec...

Page 18: ... Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified ...

Page 19: ...4VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable Connectors 10 100BaseT RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective J...

Page 20: ... Groups A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified ...

Page 21: ...ut Ripple Less than 100 mV Input Wire Size 12 24 AWG Environmental Operating Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat3 Cable 100BaseT Cat5 Cable Connectors 10 100BaseT Five 5 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warranty Effective Janu...

Page 22: ...d D Hazardous Locations or Nonhazardous Locations only EMI ANSI C63 4 FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 4 Class A Emissions EN55024 Immunity EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 SURGE EN61000 4 6 RF EN61000 4 8 PFMF EN61000 4 11 VDI GOST R Certified ...

Page 23: ...ting Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Four 4 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16...

Page 24: ...ardous Locations or Nonhazardous Locations only EMI IEC61000 6 2 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Page 25: ...ms max 24VDC Input Ripple Less than 100 mV Input Wire Size 16 28 AWG Environmental Operating Temperature 40 C to 70 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable Connectors 10 100BaseT Eight 8 RJ45 UTP Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 2 5 08 cm Warr...

Page 26: ...ons or Nonhazardous Locations only The high voltage model is TÜV approved GS per EN 60950 1 EMI EN61000 6 4 EN55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN61000 6 2 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 Conducted Disturbances GOST R Certified HV Model Only ...

Page 27: ...midity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseT Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Fiber Singlemode 7 10 125µm Fiber Fiber Transceiver Characteristics Fiber Length 2km 15km 40km 80km TX Power Min 19dBm 15dBm 5dBm 5dBm RX Sensitivity Max 31dBm 31dBm 34dBm 34dBm Wavelength 1310nm 1310nm 1310nm 1550nm Multimode Singlemode Connecto...

Page 28: ... A B C and D Hazardous Locations or Nonhazardous Locations only EMI EN 61000 6 4 EN 55011 Class A FCC Title 47 Part 15 Subpart B Class A ICES 003 Class A EMS EN 61000 6 2 IEC 61000 4 2 ESD IEC 61000 4 3 RS IEC 61000 4 4 EFT IEC 61000 4 5 Surge IEC 61000 4 6 Conducted Disturbances GOST R Certified ...

Page 29: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effect...

Page 30: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Page 31: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Two 2 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effect...

Page 32: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Page 33: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Four 4 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effec...

Page 34: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Page 35: ...C to 80 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat 3 Cable 100BaseTX Cat 5 Cable 100BaseFX Multimode 50 62 5 125µm Singlemode 7 10 125µm Connectors 10 100BaseTX Eight 8 RJ 45 TX Ports 100BaseFX Four 4 ST or SC Duplex Ports Recommended Minimum Wiring Clearance Top 1 2 54 cm Front 4 10 16 cm Warranty Effec...

Page 36: ...nd D Hazardous Locations or Nonhazardous Locations only EMI FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 2 4 EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 Magnetic Field EN61000 4 11 Voltage Dips and Interruptions GOST R Certified ...

Page 37: ... Environmental Surrounding Air Temperature 40 C to 85 C Storage Temperature 40 C to 85 C Operating Humidity 10 to 95 Non Condensing Operating Altitude 0 to 10 000 ft Network Media 10BaseT Cat3 Cable 100BaseTX Cat5 Cable Connectors 10 100BaseTX Sixteen 16 RJ 45 TX Ports Recommended Minimum Wiring Clearance Top 1 2 6 cm Front 2 5 1 cm Warranty Effective January 1 2008 all N TRON products carry a 3 y...

Page 38: ... Hazardous Locations or Nonhazardous Locations only EMI ANSI C63 4 FCC CFR Title 47 Part 15 Subpart B Class A ICES 003 Class A EMC EN61000 6 4 Class A Emissions EN 55024 Immunity EN61000 4 2 ESD EN61000 4 3 RS EN61000 4 4 EFT EN61000 4 5 Surge EN61000 4 6 RF EN61000 4 8 PFMF EN61000 4 11 VDI GOST R Certified ...

Page 39: ...RRANTIES EXCLUSIVE IF AN N TRON PRODUCT DOES NOT OPERATE AS WARRANTED ABOVE CUSTOMER S SOLE REMEDY FOR BREACH OF THAT WARRANTY SHALL BE REPAIR REPLACEMENT OR REFUND OF THE PURCHASE PRICE PAID AT N TRON S OPTION TO THE FULL EXTENT ALLOWED BY LAW THE FOREGOING WARRANTIES AND REMEDIES ARE EXCLUSIVE AND ARE IN LIEU OF ALL OTHER WARRANTIES TERMS OR CONDITIONS EXPRESS OR IMPLIED EITHER IN FACT OR BY OPE...

Reviews: