Meikon
MAMC-XLINK – Technical Reference Manual
2.2 Installation Prerequisites and Requirements
IMPORTANT
Before powering up
•
check this section for installation prerequisites and requirements
2.2.1 Requirements
The installation requires only
•
an ATCA carrier board, or a µTCA backplane for connecting the
MAMC-XLINK
, with a PCI Express lane connected to Port 4
•
power supply
•
cooling devices
2.2.2 Power supply
The power supply for the
MAMC-XLINK
must meet the following specifications:
•
+12V 0.2A Payload Power
•
+3.3V 0.1A Management Power
2.2.3 Automatic Power Up
In the following situations the
MAMC-XLINK
will automatically be reset and
proceed with a normal power up.
Voltage sensors
The voltage sensor generates a reset
•
when +12V voltage level drops below 10V (payload power)
•
when +3.3V voltage level drops below 3.08V (management power)
or when the carrier board / backplane signals AMC Disable.
2.2.4 Thermal Considerations
The
MAMC-XLINK
can be operated in a temperature range of 0°C to +70°C if the
air velocity does not fall below 1 m/s.