MYTORQ MY5-EP0212L Operation And Maintenance Manual Download Page 7

          

                                                                                                    

 

 

 

 

 

●    Do not drop or abuse the tool. 

 

●    Whenever a tool is not being used, po

sition the Power Switch to the “OFF” position and unplug the power cord. 

 

 

 

 

 

 

 

 

 

 

Attaching / detaching bit and bit type   

Push up the holder clamp by fingertip, and it will be unlocked. Thus, the bit can be freely attached and detached (single finger notion 

type) select such a bit whose shank is equal to the size shown below.         

 

 

 Insert the power plug into a receptacle and set the changeover switch to “

F

 

position. 

 Apply the bit to the screw head and press the lever or push main body to, then the switch will be turned ON to start the motor 

running. 

 When the screw is tightened and reach the torque that you had set, the tool will be stopped automatically. 

 To reset the tool by releasing the lever to the original position or releasing the bit from the screw head.   

 To return the screw, set the changeover switch to “

R

” position. 

 

Hi/Lo Switch 

 

When the MY5-EP Series rotating speed needs to be changed, set up the switch to Hi for the fastest rotation, and set 

up the switch to Lo for slowest rotation. It's possible that the uncompleted shut-off occurs when the switch is setup to Lo and the 

presetting torque is more than 50% of torque range. Please refer to the following table. 

 

 

 

 

 

 

 

 

Maintenance and Inspection: 

 

1.

 

The screwdriver must be operated in top condition, one day working hour must be not more than eight hours. 

cording to operating frequency and torque loaded, we suggest adding lubricating oils in clutch per 3-6 months,   

and kindly contact with distributor when product's maintenance. 

2.

 

Please note don’t let the motor get over heated, every minute use 10~15 screws to operate.   

3.

 

The frequency use of this electric screwdriver is over than eight hours a day, still it needs periodically testing and treatment. 

Every 5-6 months. 

4.

 

Inspect tool cords periodically and if damaged, have them repaired by  an authorized service facility. Inspect extension  cords 

periodically and replace if damaged. 

5.

 

Do not remove any labels. Replace any damaged label. 

 

 

 

Lo Switch

 

EP0212L 

EP0212LF  EP0317LF 

EP0319L 

EP0212P 

EP0212PF 

EP0317PF 

EP0319P 

NG

 

6( Kgf)

 

6( Kgf)

 

8.5( Kgf)

 

9.5( Kgf

)↓

 

6( Kgf)

 

6( Kgf)

 

8.5( Kgf)

 

9.5( Kgf

)↓

 

OK

 

6( Kgf)

 

6( Kgf)

 

8.5( Kgf)

 

9.5( Kgf

)↑

 

6( Kgf)

 

6( Kgf)

 

8.5( Kgf)

 

9.5( Kgf

)↑

 

CAUTION 

Description of Operation 

Servicing 

Summary of Contents for MY5-EP0212L

Page 1: ... MANUAL MY5 EP0212L MY5 EP0319L MY5 EP0212LF MY5 EP0317LF MY5 EP0212P MY5 EP0319P MY5 EP0212PF MY5 EP0317PF DC TYPE Automatic Non Carbon Brush with Counter Series SAING EI CORP https www mytorqtools com Y2F032Q 16E 001 Ver 4 0 ...

Page 2: ...ation enclosed Read all these instructions before placing tool in service or operation this tool and save these instructions It is the responsibility of the employer to place the information in this manual into the hands of the operator Failure to observe the following warnings could result in injury When using electric tools Basic safety precautions should always be followed to reduce the risk of...

Page 3: ... equipment such as dust mask non skid safety shoes hard hat or hearing protection used for appropriate conditions will reduce personal injuries Rubber gloves and non skid footwear are recommended when working outdoors c Avoid accidental starting Ensure the switch is in the off position before plugging in Carrying power tools with your finger on the switch or plugging in power tools that have the s...

Page 4: ...air person using only identical replacement parts this will ensure that the safety of the power tool is maintained Additional information shall be provided a Instruction for putting into use 1 Setting up or fixing power tool in a stable position as appropriate for power tools which can be mounted on a support 2 Assembly 3 Connection to power supply cabling fusing socket type and earthing requireme...

Page 5: ...t important task a user Periodically depends on the working condition and circumstance for maintaining a good function the user has to check the grounding condition every 3 6 months by an electric meter and following simple steps Set the Ohm meter to level R 100 Ohm Touching 2 test rods together and reset the meter to 0 Using the Red rod to touch the Grounding wire on the Plug of controller s cord...

Page 6: ... is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw release the trigger to stop Push Start Type screwdriver When loosen a fastened screw please set Forward Reverse switch to Reverse If the screw is reversed thread screw please set Forward Reverse switch to Forward Follow the above operation after loosening the screw stop pushi...

Page 7: ...tch to Lo for slowest rotation It s possible that the uncompleted shut off occurs when the switch is setup to Lo and the presetting torque is more than 50 of torque range Please refer to the following table Maintenance and Inspection 1 The screwdriver must be operated in top condition one day working hour must be not more than eight hours cording to operating frequency and torque loaded we suggest...

Page 8: ... center 3 SAING EI is not responsible for customer modification of tools for applications on which SAING EI was not consulted 4 Repairs should be made only by authorized trained personnel Consult your nearest KILEWS authorized service center 5 It is the responsibility of the employer to place the information in this manual into the hands of the operator DO NOT ATTEMPT TO REPAIR THIS ELECTRIC SCREW...

Page 9: ...Power Consumption 55W Torque kgf cm 1 5 12 3 19 2 12 3 19 1 5 12 3 17 2 12 3 17 Lbf in 1 33 10 44 2 57 16 46 1 77 10 44 2 57 16 46 1 33 10 44 2 57 14 78 1 77 10 44 2 57 14 78 N m 0 15 1 18 0 29 1 86 0 2 1 18 0 29 1 86 0 15 1 18 0 29 1 67 0 2 1 18 0 29 1 67 Repeatable Torque Accuracy 3 Torque Adjustment Stepless Unloaded Rotation Speed r p m 10 HI 1000 1000 1000 1000 2000 2000 2000 2000 LO 700 700 ...

Page 10: ...0 L1 L9 10 90 Rated speed L0 Ht 0 1 9 9 Ht time Stop time Show wrong as screwdriver can t stop at set time after starting can be used to test stripped screws Without release trigger from screwdriver the buzz is on continuously and red LED keeps flashing 2 0 Lt 0 01 9 9 1 Lo time An ERROR happens when the time of screwdriver stopped working from started less than the time has set in Lt setting 2 02...

Page 11: ...Keypad LOCK P S R button UN UNLOCK Alarm Settings UP DOWN Function Name Set up Time and Value Description Buzz Time Light Factory default settings ON When OK OKALL or NG happens the alarm will be on to warn operators OFF When NG happens the alarm will be on to warn operators FF When OKALL or NG happens the alarm will be on to warn operators EF When OK or OKALL happens the alarm will be on to warn ...

Page 12: ...DOWN to change number and then push S confirm 3 Show At automatic zero UP DOWN to change value then push P confirm 4 Enter simulate learning LED 1 will keep flash 5 When recording value push P key and back working condition J5_ EXT PORT NO Function 1 OKALL 2 NG 3 OK 4 X 5 GND ON Fastening a screw completing work and mistaken operation buzzer will be on OFF Wrong operation will be buzzed FF Work co...

Page 13: ...ting time If three seconds are set but no starting signal after set time it will buzz Push R key to restore to factory settings General execution of pre set program Start LL 1 5 Lt 1 00 If stop is among dots it is normal fastening OK will be shown If stop is before Lt or over Ht it is N G User can freely adjust Lt However if Ht and Lt is closer it will request more accuracy Ht 5 0 OK N G N G ...

Page 14: ...ewdriver The clamping torque of screw itself is different from the clamped conditions Understand the correlation between clamping torque values and the torque checker values perform the torque control properly 1 Also in reverse rotation the clutch is turned off in such manner as in normal rotation stopping the motor running Accordingly when the screw tightened at a large torque set it to a higher ...

Reviews: