7. USB 

Brooklyn AMP can be controlled by using Mytek Control Panel application. To downlad and install the 

software please visit our support page: https://mytekdigital.com/hifi/support/

8. Firmware update Windows and OS X

The current revision of the Brooklyn AMP firmware is shown in the MytekControl „General” tab.

• 

The firmware can be updated by using USB2 port and Mytek Control Panel application. It does not 

require installed USB2 driver (PC). To download the current firmware please visit:

 

    mytekdigital.com 

Follow the steps below to update the firmware:

1. 

Download the latest firmware (*.mfb) file from mytekdigital.com

2. 

Click „Load firmware file” button and browse to the new firmware file then click „Open”.

3. 

Press the „Update” button to confirm uploading the firmware file to device’s memory.

4. 

Confirm your choice by clicking „Yes” when warning dialog appears. A progress bar will indicate 

when the flash process is finished.

5. 

When the update is finished the the AMP will be switched off. To switch it on press the button on 

the front panel once. 

9. 

Technical Specification

Output Power in stereo and bi-amp mode,1kHz @ 8, 4, 2 Ohm: 2x 300W
Output Power in bridge mode, 1kHz @ 8, 4Ohm: 1x 600W
Burst Output Power in stereo and biamp, 1kHz @ 8, 4, 2 Ohm: 2x 500W
Burst Output Power in bridge mode, 1kHz @ 8, 4 Ohm: 1x 1000W

Output voltage in stereo and biamp mode: 70Vp/140Vpp unloaded
Output voltage in bridge mode: 140Vp/280Vpp unloaded

Frequency Response -3dB: 10 Hz - 30 kHz: +0/-0.25 dB 

Upper bandwidth @ -3dB for RL = 8 Ohm: 85kHz
Upper bandwidth @ -3dB for RL = 4 Ohm: 65kHz
Upper bandwidth @ -3dB for RL = 2 Ohm: 44kHz

THD+N (1kHz @ 1W): 0.002 %
THD+N (typical): < 0.04 % (20 Hz - 20 kHz, 8 Ohm load, 3 dB below rated power)
Signal To Noise-Ratio: > 121 dB (A-weighted, 20 Hz - 20 kHz, 8 Ohm load)

Input gain control: 23dB (default), 29dB dip switch selectable
Input Impedance: 10 kOhm

Operation Voltage Universal Mains: 85-265V

Protection Circuits: short circuit protection, DC protection, 
under voltage protection, temperature protection, overload protection

Dimensions: WxDxH:8.5x9.5x1.74” / 216x241x44mm
Weight: 6lbs / 3 kg
Warranty: 2 years

Summary of Contents for Brooklyn AMP

Page 1: ...Owner s Manual DUAL MONO COMPACT Hi RES POWER AMPLIFIER ...

Page 2: ...l be posting new firmware releases in the support download section on Mytek website Firmware may alter details of Mytek operation and consequently there will be periodic updates to this manual For news driver updates technical support tips and further product information please visit our website mytekdigital com Technical support issues are handled via our online support ticketing system Please en...

Page 3: ...on under voltage protection temperature protection overload protection Mytek Software accessible via usb micro allows for possible future firmware update and unit identification LED logo power indicator 2 Introduction Thank you for choosing the Brooklyn AMP from Mytek Digital and welcome to the Mytek users community Brooklyn AMP is a reference power amplifier with signature Mytek sound musical det...

Page 4: ...g RCA Dipswitches 7th and 8th work together when 7 is up the AMP works in a regular stereo mode when 7 is down the AMP mode depends on dipswitch 8 setting when 8 is up the AMP works in Bi amp mode when 8 is down the AMP works in a Bridge mode 6 OPERATING MODES and their settings STEREO default mode channels left and right operate independently as with a conventional stereo amplifier The right inpu...

Page 5: ...inished 5 When the update is finished the the AMP will be switched off To switch it on press the button on the front panel once 9 Technical Specification Output Power in stereo and bi amp mode 1kHz 8 4 2 Ohm 2x 300W Output Power in bridge mode 1kHz 8 4Ohm 1x 600W Burst Output Power in stereo and biamp 1kHz 8 4 2 Ohm 2x 500W Burst Output Power in bridge mode 1kHz 8 4 Ohm 1x 1000W Output voltage in ...

Page 6: ... servicing to qualified service personnel Servicing is required when the apparatus has been damaged in any way such as power supply cord or plug is damaged liquid has been spilled or objects have fallen into the apparatus the apparatus has been exposed to rain or moisture does not operate normally or has been dropped Warning Excessive sound pressure from speakers and headphones can cause hearing l...

Page 7: ......

Reviews: