2 - Machine Operation

2.1 - Powering the 

Breeze™

Connect power cords by 

lining up the female end 

of the cord with the male 

prongs in the socket on the 

machine. Twist clockwise to 

lock the cord in place.

Each power cord on the Breeze™ requires a grounded 20 

amp outlet. For dual cord machines, plug each cord into 

its own 20 amp circuit. The dual circuit indicator light and 

tone will activate when this is achieved. 

2.2 - Connecting 

Hoses

Use the included Cuff-Lynx™ 

hose connectors to connect 

1.5” or 2” vacuum hose to 

the Breeze™. Connect the 

solution hose via the quick 

connect fitting on the front  

of the Breeze™ as shown 

here. 

2.3 - Filling the Solution Tank

The Breeze™ solution tank can be filled up from a bucket 

via the opening under the solution tank lid. 

2.4 - Switching On the Breeze™ Components

Units Without Heater (BZ-102LX, BZ-102LX-AUTO, 

BZ-105LX, BZ-105LX-AUTO)

After a cleaning tool is connected and the solution tank is 

filled, switch on the vacuums and the pump in any order.

Units With Heater (BZ-102LXH, BZ-103LX)

In order to avoid vapor locking the unit, the components 

should be switched on by following the procedure below 

after a cleaning tool is connected:

1. Turn pump switch on. Pull the lever on the cleaning tool 

to release air in the line. Hold lever until a steady flow of 

water comes out of the wand. 

2. Once pump is primed and there is pressure in the 

solution line, turn on heater switch and wait a few minutes 

for water to heat up. 

3. Once water is heated, turn on vacuum and begin 

cleaning.

BZ-102LXH Variable 

Switch

The variable switch on the 

BZ-102LXH model allows 

you to switch between the 

heater and VACUUM 2. 

Follow the same procedure 

shown above when heater 

will be used. 

VAC 1 PUMP VAC 2

HEATER

VAC 1

VAC 2

PUMP

HEATER

3

1 2

Summary of Contents for Breeze BZ-102-LXH

Page 1: ...LXH BZ 102LX AUTO BZ 103LX BZ 105LX BZ 105LX AUTO User Manual 13655 Stowe Dr Poway CA 92064 P 858 679 1191 F 858 726 6005 www mytee com REV 6 16 20 Please read and understand this manual completely b...

Page 2: ...chine abusing it or not operating it properly can void its warranty and prevent the machine from performing to the quality and standard you d expect out of the Mytee Products line If you have any warr...

Page 3: ...g the Breeze 9 2 2 Connecting Hoses 9 2 3 Filling the Solution Tank 9 2 4 Switching On the Breeze Components 9 2 5 Chemical Injection BZ 105LX AUTO Only 10 2 6 Auto Fill and Pump Out AUTO Units Only 1...

Page 4: ...ice Please contact Mytee service personnel or a Mytee au thorized Service Center using Mytee original replacement parts and accessories if repairs need to be performed When and if calling Mytee for su...

Page 5: ...eas where flammable or combustible material may be present 12 Do not leave the unit exposed to harsh weather elements Temperatures below freezing may damage com ponents and void warranty 13 Use only t...

Page 6: ...30 Cord One 8 amps Cord Two 8 amps Net Weight 112 lbs Machine Dimensions 20 x 29 x 37 BZ 105LX Solution Tank 10 gallons Recovery Tank 10 gallons Vacuum Motors Dual exclusive Mytee LX vacuum motors 225...

Page 7: ...NO C SIZE TITLE NAME DATE COMMENTS CHECKED DRAWN FINISH MATERIAL DIMENSIONS ARE IN INCHES TOLERANCES ANGULAR MACH 5 ONE PLACE DECIMAL 03 TWO PLACE DECIMAL 05 THREE PLACE DECIMAL 003 PROPRIETARY AND C...

Page 8: ...8 1 At a Glance 1 Rear push handle 2 Loading Buddy wheel attachment 3 Twist lock power cord sockets 4 10 rear wheels 5 Switch plate 1 4 Breeze Rear View 1 2 3 4 5...

Page 9: ...the Breeze Components Units Without Heater BZ 102LX BZ 102LX AUTO BZ 105LX BZ 105LX AUTO After a cleaning tool is connected and the solution tank is filled switch on the vacuums and the pump in any or...

Page 10: ...uto fill connection on the front of the unit Turn on the water source and let the tank begin to fill It will shut off when the water level reaches the float switch in the solution tank Pump out Connec...

Page 11: ...achine will open up 3 2 System Maintainer Weekly flushing of the solution system with Mytee System Maintainer helps keep lines clean and prevents chemical build up improving pump life performance and...

Page 12: ...ed the wrong way Make sure this plastic boot is turned toward the right wall of the machine and not toward the ball float There is a loud grinding noise coming from the vacuum Possible Cause Solution...

Page 13: ...r when using your machine it is rec ommended you do one wet pass followed by two dry passes This way you are not spraying as much and the hot water will last longer Jets being used are too large If yo...

Page 14: ...Mytee Products Inc 13655 Stowe Dr Poway CA 92064 www mytee com 2020 Mytee Products Inc Printed in the USA NOTES...

Reviews: