MyTana MV80 User Manual Download Page 5

PG  5

largest possible hose size in order to have as much pressure 
as possible at the end of the hose. 
Hoses of the same diameter may be coupled together 
but it is not recommended for use in lines smaller than 8” 
diameter. The solid metal of the combined hose connectors 
and coupling, can get caught in bends in the line.

Pulse-abler

The stem and handle extending from one cylinder of 
the water pump enables pulsation of the water stream 
through the hose and nozzle. 
By turning the pulse-abler handle clockwise (or right), 
you temporarily disable one valve of the pump. This 
creates pulsation or vibration in the hose, allowing the 
hose to “wiggle” through tight bends quickly and easily. 
Turn the pulse-abler control left to stop pulsation. 

Use pulsation only as needed to arrive at an  
obstruction or to retrieve a stuck hose.  
See more in Care Tips section, page 7.

Garden hose 

hook-up

Throttle

Choke

Electric Start

Jumper 

Hose

Ball valves

Pressure Regulator/Unloader

The regulator/unloader both regulates the pressure and 
relieves pressure on the pump while in bypass. 
The Regulator knob is located at the pump. It allows you to 
adjust pressure during operation. 

Set the engine throttle 

to a constant motor speed before adjusting pressure 

regulator, 

lower rpm equals lower pressure at the pump, 

while high rpm delivers higher pressure. 
The Unloader prevents pressure overload in the event that 
the nozzle is plugged or the ball valve is shut off. When  
in the by-pass mode, the pump will continue to run. 

Avoid running in by-pass mode for more than  
2 minutes if the by-pass is not returning to the  
float tank. It can damage the pump.

Pressure Gauge

The gauge reflects pressure from the pump only, not 
pressure at the end of the hose. It is important to select the 

MyTana    MV80  |  MS80   User Manual

Summary of Contents for MV80

Page 1: ...Quality Sewer Drain Cleaning Equipment since 1957 800 328 8170 Factory Direct Customer Service M F 7am 5pm CST Competent Polite Clear www MyTana com 746 Selby Ave St Paul MN 55104 fax 651 222 1739 Use...

Page 2: ...ter back toward the operator at a 20 to 45 degree angle This backward stream propels the sewer nozzle and accompanying hose forward into the sewer line and also cleans the walls of the pipe Jetting pu...

Page 3: ...polyvinyl chloride or neoprene covering of the hose NEVER clean the machine using its own spray The machine is water protected but not water proof High pressure spray could damage machine components...

Page 4: ...diameter of the hose the greater of loss of pressure per foot will be The MS and MV80 jetters are optimized for 250 of 3 8 hose The orifices holes in the nozzle affect pressure Over time water pressu...

Page 5: ...n or to retrieve a stuck hose See more in Care Tips section page 7 Garden hose hook up Throttle Choke Electric Start Jumper Hose Ball valves Pressure Regulator Unloader The regulator unloader both reg...

Page 6: ...rotate the loop 90 to 180 until the hose advances If the hose still fails to advance switch to a smaller diameter hose Once you are through that area pull back and pass through several times to ensur...

Page 7: ...ze into pump and hose as part of your shut down procedure Simply insert a short length of garden hose into a gallon of antifreeze turn on pump an run until you see antifreeze coming out of the nozzle...

Page 8: ...r O rings Change oil at regular interval Inadequate water supply to pump creating a vacuum lock Ensure adequate tap water supply clear inlet filter Oil leaks Worn pistons and or leaking crank seals cr...

Reviews: