06
LO-LINE RC & LO-LINE RC Heater Cooler
G
This unit is supplied with factory fitted test leads. Remove
these and discard.
G
A fused electrical spur with a maximum 3A fuse and a switch
having 3mm separation on all poles must be provided in an
easily accessible position adjacent to the unit.
G
Electrical cable entry to the unit should be made through the
underside of the unit using the cable gland provided, or
through the hole provided at the upper right hand corner of
the chassis.
G
Connect live and neutral wires to the power board terminal
connections, and the earth wire to the chassis earth terminal.
8.0 Electrical Connection
WARNING: This appliance must be earthed. The electrical installation must comply with local or national
wiring regulations.
O O
L N
Motor
Power Board
Control Board
Air Sensor
Water Sensor
O O
Brown
Blue
White
Yellow
Wiring Diagram