05
KICKSPACE
®
600E
5.0 Airflow
6.0 Operation
100mm
600mm
The square red switch on the left hand side switches the unit on and
connects the mains supply to the fan motor (giving a cool airflow)
and energises the heat control switches.
7.0 Heat Control
When the left switch on the right hand side is depressed it will
illuminate and the heat output is 1kW. When the right-hand switch
is depressed it will illuminate and the heat output is 2kW. When both
switches are depressed the heat output is 3kW.
The appliance is fitted with an electronic Safety Control (ES). This is
a safety device which switches off the heater if, for any reason, the
appliance overheats. The ES Controls can only be reset after the
appliance has cooled down. In order to reset the ES Control proceed
as follows:
1. Switch off appliance and leave for approximately 5 minutes.
2. Switch on appliance and ES Control will reset.
Ensure that the appliance is functioning correctly. If the ES Control
operates again, the appliance should be checked by a competent
electrician.
8.0 Connection to the Main Supply
Electrical installation should be carried out by a competent installer,
preferably registered with NICEIC (National Inspection Council for
Electrical Installation Contracting) in accordance with the 17 edition
of the IEE Wiring Regulations, (BS.7671), and any relevant Local
Authority bye-laws.
This heater is fitted with a 3-core mains supply cable and should be
permanently connected to the electricity supply via a double pole
switch having 3 mm gap on each pole.
A switched Fused Connection unit to BS.1363 Part 4 is a
recommended mains supply connection accessory to ensure
compliance with safety requirements applicable to fixed wiring
installation.
CAUTION: IN ORDER TO AVOID A HAZARD DUE TO
INADVERTENT RESETTING OF THE THERMAL CUTOUT, THIS
APPLIANCE MUST NOT BE SUPPLIED THROUGH AN EXTERNAL
SWITCHING DEVICE, SUCH AS A TIMER, OR CONNECTED TO A
CIRCUIT THAT IS REGULARLY SWITCHED ON AND OFF BY THE
UTILITY.
2.0
3.0
4.0
5.0
6.0
7.0
8.0
KICKSP
ACE
®
600E
INST
ALLA
TION, OPERA
TING,
MAINTENANCE & AFTER SALES MANUAL. 01.05.2014