KICKSPACE

®

Dimensions 

(continued)

KICKSPACE

® 

Kickboard Dimensions

Dimensions of opening to be cut in Kickboard - 

KICKSPACE

®

500, 600, 600-12V, 800, 500 Duo, 

500E, 600E

Option A (Excluding 500E)

Option B (Excluding 600E)

Model

A

B

C

500, 500 Duo, 500E

466

99

17

600, 600-12V

520

99

17

800

573

99

17

600E

540

95

N/A

KICKSPACE

®

Floor

Connections

Dimensional View

KICKSPACE

®

600E

KICKSPACE

®

500E

496

101

321

203

177

FRONT GRILLE

Mains Cable

Top view

Cable entries

View on arrow

93

88

225

120

360

120

600

100

175

Cable entry

View on arrow

105

70

14

38

38

240

362

402

248

Cable entry

Flow and Return
connections

244

422

240

362

210

Flange depth

Flange width

N.B:

All connections accessible 

from the top of unit.

KICKSPACE

®

Te c h n i c a l   I n f o r m a t i o n

2 1

Dimensions (mm)

N.B:

KICKSPACE

®

500E: Add 4.5mm

to the chassis height of the above
models to allow for rubber mountings
and screws.

Summary of Contents for Kickspace 500

Page 1: ...ter allows freedom to tailor your home around your lifestyle Central heating electric and duo models available All units are now supplied complete with a white grille The KICKSPACE can also be used alongside the MYSON INNOKO towel rail to provide the perfect drying and heating solution for any kitchen For information on the MYSON range of towel warmers please contact Customer Services KICKSPACE Th...

Page 2: ...room Controls are situated on the front grille with the unit having a choice of heating fan speeds winter setting as well as a fan only summer setting operation Alternatively a remote control wall switch can be fitted to central heating and duo models for extra control and convenience Effective climate control KICKSPACE 07 ...

Page 3: ...ts but equally the bathroom or hallway can offer alternative applications All versions except the floor model are designed to be installed horizontally into recessed locations They require an adequate supply of inlet air and the axis of the motor must remain horizontal KICKSPACE Applications KICKSPACE Floor model ...

Page 4: ...tions The remote room thermostat is supplied white as standard and is suitable for the 500 600 800 hydronic models Accessories Central Heating 500 600 800 Floor 600 12V Electric 500E 600E Duo Central Heating Electric 500 Duo For technical information please refer to pages 17 21 Model details Grilles Remote wall switch Remote room thermostat ...

Page 5: ...obore pipe work l Fan convectors are not suitable for one pipe systems l Where the unit is fitted onto a system with other emitters a separate circuit for the fan convector should be considered to ensure an adequate water flow through it l The heating system water temperature must be greater than 43 C in heating mode for the unit to operate lower temperatures possible for heat pump applications on...

Page 6: ...Cable Transformer Fan Only Option Supplied Supplied Yes Isolating Valves 15mm 1 metre low voltage fitted Supplied external from product 1 metre mains fitted KICKSPACE 600 12V 750mm x 10mm bore EPDM hoses sheathed in AISI 304 stainless steel braid Please note that KICKSPACE 600E grilles are an integral part of the product and can not be changed KICKSPACE Technical Information 17 Electric Product Ra...

Page 7: ...366 Boost 1035 1178 1322 1468 1615 3531 4018 4510 5008 5510 Heat Output watts Heat Output Btu h Hydronic Heating Performance Data Heat outputs tested in accordance with BS 4856 Part 1 Hydronic Models It is preferable to select the model with an output capable of maintaining the calculated heat losses of the room when operating at normal speed This will enable the boost fan speed and the higher tem...

Page 8: ...r 28 0 15 5 5 600 12V 40 0 30 7 9 500 Duo 25 0 26 4 5 500 70 90 2471 3177 600 106 138 3742 4872 800 139 210 4908 7415 Floor 76 169 2684 5968 600 12V 106 138 3742 4872 500 Duo 70 90 2471 3117 Air Flow Model Low Low High High Air Flow m3 h Air Flow ft3 h 500E 70 90 2471 3177 600E 210 N A 7560 N A Electric Heating Performance Data Model Low High Medium Heat Output watts 500E 1000 N A 2000 600E 1000 2...

Page 9: ...Electric KICKSPACE 500E 600E 500E supplied with 2 metres of cable 1 0mm Requires a supply fused at 10A 600E supplied with 2 metres of cable 1 0mm Requires a supply fused at 13A KICKSPACE Dimensions KICKSPACE 800 KICKSPACE 600 KICKSPACE 500 KICKSPACE 500 Duo KICKSPACE 600 12V N B Add 4 5mm to the chassis height of the above models to allow for rubber mountings and screws 496 101 309 82 36 129 322 2...

Page 10: ...s Dimensional View KICKSPACE 600E KICKSPACE 500E 496 101 321 203 177 FRONT GRILLE Mains Cable Top view Cable entries View on arrow 93 88 225 120 360 120 600 100 175 Cable entry View on arrow 105 70 14 38 38 240 362 402 248 Cable entry Flow and Return connections 244 422 240 362 210 Flange depth Flange width N B All connections accessible from the top of unit KICKSPACE Technical Information 21 Dime...

Reviews: